  • The Update 6000 contains various enhancements and fixes since the original release of ARCHICAD 22.
  • CRASH: A beam that intersected with a wall of 0 thickness crashed ARCHICAD.
  • CRASH: A properties corruption caused ARCHICAD to crash when opening any tool.
  • CRASH: ARCHICAD crashed on loading a project index, if a view had a corrupted renovation filter setting.
  • CRASH: ARCHICAD crashed on some iMac computers when entering full screen.
  • CRASH: ARCHICAD crashed using "Align to Decimal" alignment.
  • CRASH: ARCHICAD crashed when a complex profile wall's fillet radius was less than the width of the wall.
  • CRASH: ARCHICAD incorrectly handled the rendering of large textures.
  • CRASH: ARCHICAD sometimes crashed when hotlinks with parametric profiles were updated.
  • CRASH: ARCHICAD sometimes crashed when processing railings with geometries modified by other objects.
  • CRASH: ARCHICAD sometimes crashed when trying to import an XML file back from Excel.
  • CRASH: ARCHICAD sometimes crashed while releasing memory at closure.
  • CRASH: Inherited sub-elements from parent elements with properties were not handled properly.
  • CRASH: Interior Wizard incorrectly handled the undo queue.
  • CRASH: Library migration sometimes failed while processing walls.
  • CRASH: Opening a section that cut through windows in composite walls sometimes resulted in a crash.
  • CRASH: Spell Check addon with Microsoft Office dictionary crashed ARCHICAD.
  • CRASH: The pickup/inject parameters tool was not safe in curtain wall editing mode.
  • CRASH: Connection/merge of roof/shell elements had a limited number of times it could be run before crashing ARCHICAD.
  • DOCUMENT/CRASH: Fills created incorrectly by a faulty algorithm in an earlier build of ARCHICAD were not automatically corrected and crashed the ARCHICAD during the generation of the layout that contained the fill.
  • DOCUMENT: A drawing from a rotated view source sometimes changed when zooming took place in the view.
  • DOCUMENT: An opening's dimension markers were overridden, when placed on a layout.
  • DOCUMENT: ISUNDEFINED function of the Expression-based Properties was not evaluated correctly for Option Set type Properties.
  • DOCUMENT: Labels did not display Properties correctly on Layouts, if the source View was opened.
  • DOCUMENT: Lines of elements sometimes disappeared on a layout with a corrupted drawing.
  • DOCUMENT: Semi-transparent images were printed darker than they were on the screen.
  • DOCUMENT: Sometimes a curtain wall's source view differed in its appearance on layout.
  • DOCUMENT: The layout number in subset autotexts displayed incorrect values for split layouts.
  • DOCUMENT: Expression Defined Properties did not consider the displayed accuracy of values, and for this reason rounding operations sometimes gave unexpected results.
  • EDIT/CRASH: Edits to a criterium or atribute that later were revoked were not robustly handled leading sometimes to crashes.
  • EDIT/CRASH: If Grasshopper palette was open, ARCHICAD crashed while placing a curtain wall.
  • EDIT/CRASH: The modification of the ID of Skylights in the Settings dialog caused a crash.
  • EDIT/ROOF/CRASH: ARCHICAD crashed when the roof was set from simple to complex geometry method.
  • EDIT: A traced element's hotspot could not be snapped to if it fell outside the set range of the Section/Elevation displayed in the current window.
  • EDIT: Holes of a beam disappeared, after the beam's ID was changed with the ID Manager.
  • EDIT: If the Find&Select palette was open, objects that referenced zones had slow parameter transfer.
  • EDIT: Overridden fills and lines, that were placed on a section, appeared with a different color on a layout.
  • EDIT: The option "Move sub-element" on layout's pet palette was only available when clicking on the drawing's center point.
  • EDIT: The size of the copied text changed when zoom was used before pasting the text to be copied.
  • EDIT: With command Trim Elements to Roof/Shell, only bottom edges of elements to trim were highlighted.
  • FILE/.MTL/EXPORT: An exported .mtl file path was incompatible with localized versions of ARCHICAD.
  • FILE/3DM/IMPORT/CRASH: If a Rhino model contained elements with invalid material attributes, its import into ARCHICAD sometimes resulted in a crash.
  • FILE/DAE/IMPORT: ARCHICAD could not import Collada files.
  • FILE/DWG/EXPORT/CRASH: A self-referencing XREF crashed ARCHICAD.
  • , 258500 FILE/DWG/EXPORT/CRASH: ARCHICAD sometimes crashed while publishing DWG with Xref-s including frozen (hidden) layers.
  • FILE/DWG/EXPORT/CRASH: ARCHICAD crashed because of a nested XREFed DWG(s) with an invalid path.
  • FILE/DWG/EXPORT: An imported DWG file with images, when exported from ARCHICAD lost its images.
  • FILE/DWG/EXPORT: Graphical overrides made line thicknesses the same in the exported DWG.
  • FILE/DWG/EXPORT: Objects did not convert to blocks with 'convert complex objects to blocks' translator setting.
  • FILE/DWG/IMPORT/DOCUMENT: Attribute definitions were not displayed from AutoCAD blocks, if they were not translated as library parts.
  • FILE/DWG/IMPORT: Text with annotative style was missing from imported DWG files.
  • FILE/IFC/EXPORT: Component Name parameters were numbers instead of Building Material Names.
  • FILE/IFC/IMPORT/MODEL: IFC import sometimes gave incorrect size information to objects.
  • FILE/IFC/IMPORT: IFC nested mapped elements were imported to ARCHICAD incorrectly.
  • FILE/OBJ/EXPORT: Textures were missing from wavefront files when their names had special (non-English) characters in them.
  • FILE/OPEN/CRASH: ARCHICAD crashed when opening a file from START Edition 2011 because Find and Select criteria were incorrectly converted during the file migration process.
  • FILE/OPEN/CRASH: ARCHICAD sometimes crashed while opening a project with certain settings for stairs.
  • FILE/OPEN: Previously saved witness lines settings of doors in a schedule switched back to their default settings after reopening the file.
  • FILE/PDF/EXPORT: Dense fills caused memory leaks during PDF export.
  • , 255095 FILE/PDF/SAVE: ARCHICAD crashed when Issue History Index was saved as PDF with the 'Open after saving' option checked.
  • FILE/XLSX/IMPORT/DOCUMENT: The property values import time degraded since the last release of ARCHICAD.
  • FILE/XML/EXPORT: Model View Options Combination with a colon character in its name could not be exported on Windows.
  • FILE/XML/EXPORT: The SOH character sometimes was added to the exported XML, that resulted in an invalid XML file.
  • FILE: More robust logging was enabled.
  • FREEZE: On mac, ARCHICAD froze while starting Roof Wizard, if its default layer was missing.
  • FREEZE: Override combinations were not processed optimally.
  • FREEZE: The snap guide was not equipped to handle more than 100 hotspots in one close region.
  • GOODIES/CRASH: ARCHICAD sometimes crashed when trying to set a favorite with the Interior Wizard.
  • GOODIES: Accessory element were placed as existing although the new status was chosen on the Renovation palette.
  • GOODIES: Polygon Counting Tool was slower compared to the previous ARCHICAD versions.
  • HOTLINK/CRASH: An associative railing that was linked to a different story than its parent element, placed as hotlink in a way that parent element didn’t fit in host file’s story structure, sometimes caused a crash while updating the hotlink.
  • HOTLINK/IFC/CRASH: ARCHICAD sometimes within add-ons like Archiframe 22 crashed with hotlinked IFC files.
  • MODEL/CRASH: ARCHICAD crashed because of a break mark calculation of a malformed railing of a stair.
  • MODEL/CRASH: ARCHICAD crashed with a stair having drains on both sides with a greater offset value than the entire stair.
  • MODEL/EDIT: Stairs in a Marquee could not be dragged.
  • MODEL/MEP/FREEZE: Several MEP objects, like the pipe bend were not optimized for 3D navigationThey relied too heavily on the parameter script.
  • MODEL/USER INTERFACE: Custom fills created from curved shapes that contained fills failed to render correctly in 2D.
  • MODEL: "Best Match" tracing method of the Magic Wand Settings blocked creation of curved polylines.
  • MODEL: A static dimension on a hidden layer moved with the marquee.
  • MODEL: Beams were connected wrong in 3D, if they had an axis line offset.
  • MODEL: Beams with different offsets joined incorrectly.
  • MODEL: Curtain Wall frame connections sometimes incorrectly joined similarly prioritized elements.
  • MODEL: Fills were not shown in Trace & Reference when the Work Environment Advanced Redraw Option for Model display was set to Simplified Model.
  • MODEL: From certain angles of view, edges of construction elements appeared too thick with OpenGL.
  • MODEL: If a column was placed elsewhere than origin, and its angle to Z axis was changed on section/elevation, angles to X and Y changed as well.
  • MODEL: It was not possible to extrude several morphs at the same time.
  • MODEL: Multiple selected objects that were nudged in a rotated view moved in an apparently random direction.
  • MODEL: The creation of a wall or the dragging of a wall sometimes happened very slowly due to the zone it belonged to.
  • MODEL: The default angle of a Curtain Wall remained 90°, if the angle of the applied favorite was smaller than 1°.
  • MODEL: The Magic Wand was not able to select complete polylines from the trace.
  • MODEL: The mirroring of a railing did not consider its offset.
  • MODEL: When a roof's cover fill was unchecked, it still appeared on view when overridden.
  • RENDERING: CineRender settings of a migrated project differed from the original source version.
  • SPEED: Saving complex railing in a DWG file was slow.
  • TEAMWORK/MODEL/HOTLINK: Railings sometimes lost balusters, if they were hotlinked from a Teamwork project.
  • TEAMWORK: After a BIMcloud update some users experienced slow reservation times.
  • TEAMWORK: No warning text appeared after opening a Teamwork file which had been previously packed by Travel Pack.
  • TEAMWORK: Project preferences data relating to zones were not correctly handled in Teamwork.
  • TEAMWORK: Reservation palette sometimes was slow to respond.
  • TEAMWORK: Sometimes it was not possible to remove embedded library folders.
  • USER INTERFACE: In macOS 10.14Mojave, scrolling in the navigator garbled the text.
  • USER INTERFACE: Operation Profiles could not be selected in the list in their settings dialog using the up and down arrow keys of the keyboardThe selection seemed to change with pressing the keys, but the Operation Profile did not get selected.
  • USER INTERFACE: The 3D texture alignment was not greyed out when the function was not available.
  • ZOOM: Zooming with track pad on a rotated view not only changes size of object but also offset objects on a spiral path.

New in ArchiCAD 22 Build 3006 (Jul 24, 2018)

  • Façade Design:
  • The remastered Façade Design tool provides flexible design environment for architects to create external or internal facades, elevations and surfaces with modular structures and hierarchical, repetitive patterns. Designing and detailing Curtain Walls is not only more accurate but it’s also easier to adherence local requirements for documenting and listing.
  • Parametric Profile Editor:
  • The Parametric Profile Editor combines the power of parametric design with the freedom of graphical profile creation. Create more intelligent Profiles for Walls, Beams and Columns, by defining parametric edges in the Profile Editor. This will allow offset individual or multiple edges centrally for the Profile Attribute or at the instance level - either graphically or via element settings.
  • Expression Defined Property Values:
  • Architects may benefit from defining complex data-processing expressions for elements. The result can be used in ARCHICAD for tagging or filtering elements, and presented in any graphical, tabular or model output, governed by arithmetic, logical and text handling operations very similar to functions in standard spreadsheet programs.
  • Performance:
  • ARCHICAD 22 introduces a smooth and truly responsive panning and zooming navigation experience for 2D views, even in very large projects. ARCHICAD utilizes ultra-high 4K and 5K monitor screen resolution on Microsoft Windows 10 operating systems too, similarly to the retina display on Mac. The representation of fine details of icons, lines, texts and other graphic user interface elements are now produce a much sharper look.
  • Professional Visualization: CineRender v19 Engine:
  • ARCHICAD 22 uses Maxon’s latest (R19) CineRender engine and enables architects to utilize professional visualization processes and features without leaving ARCHICAD. Now Tone Mapping, Stereoscopic and 360-degree or spherical renderings can be created.
  • Custom Graphical Labels:
  • Select any combination of drawing primitives (lines, arcs, polylines), plus Text Blocks (including Element-related Autotexts), then save and use them as a Label.
  • IFC Import and Export enhancements:
  • ARCHICAD supports the import of geometry representation of double-curved, complex geometry elements, the non-uniform rational basis splines (NURBS) from IFC4 files. Properties and quantities of components (composite skins, complex profiles, multibody object parts) can be exported for quantity take-off and cost estimation applications.
  • Updated Attribute Manager dialog:
  • The Attribute Manager dialog has been re-engineered to work faster and more reliably. New features include: instant search of Attributes of the left and/or right side and when switching between Tabs; delete and replace functionality now works directly; Layers and Layer Combinations merged into a single Tab, allowing Layer states to be edited across multiple selected Layer Combinations; support for editing of multiple Attributes simultaneously.
  • Updated Model View Options dialog:
  • The Model View Options dialog has been redesigned, to match the layout of other dialogs, with the following changes: MVO Combinations and the Search field are now on the left side of the dialog; ‘Store as’ and ‘Rename’ functions have been removed; Panels on the right side of the dialog have been reorganized and simplified; during migration, previous “Custom” Sets used by project views will become automatically named MVO Combinations.
  • Updated ARCHICAD-Grasshopper Connection Tool:
  • Thanks to the latest development ARCHICAD’s enhanced Curtain Wall feature set is fully accessible from Grasshopper. Designers may start assembling Curtain Wall Patterns using any set of 2D lines as well as manage all sub-elements on the Grasshopper Canvas and create astonishing facades in ARCHICAD using algorithmic design definitions.
  • Various enhancements and fixes:
  • 233926 BIMcloud/TEAMWORK/HOTLINK: Hotlink update was giving a Teamwork error message when using the host file, if another user was deleting the source file.
  • 237662 CRASH: Search and Replace crashed with certain Japanese character strings.
  • 235560 CRASH: ARCHICAD could crash when switching from one story to another.
  • 235695 CRASH: ARCHICAD crashed in certain circumstances when using the mark-up tool.
  • 229789 CRASH: ARCHICAD crashed while switching to 3D because of corrupted stairs.
  • 235422 CRASH: ARCHICAD did not robustly handle some room boundaries.
  • 237127 CRASH: ARCHICAD did not test IFC files for adherence to the standard before trying to open them, and crashed with poorly made IFC files.
  • 242531 CRASH: The grid tool incorrectly handled multi-byte characters in one of its settings dialogs.
  • 235032 CRASH: The PolyCount could fail to calculate the polygons of stairs and occasionally it crashed.
  • 229129 DOCUMENT/CRASH: ARCHICAD crashed when certain views were placed on the layout.
  • 238944 DOCUMENT/HOTLINK: The Door/Window Stamp placed in the module file did not show the properties in the host file.
  • 235765 DOCUMENT: An object belonging to more than one Zone with each Zone having a different Renovation status could report an incorrect related Zone number and name in a schedule.
  • 239263 DOCUMENT: ARCHICAD could crash when publishing empty PDF files.
  • 234196 DOCUMENT: Dimensions were sometimes temporarily lost on the Floor Plan when switching to Section/Elevation and back.
  • 233995 DOCUMENT: Doors were not considered to belong to a zone, if they were inside it, not on its edge.
  • 236332 DOCUMENT: Elevation Dimension Text Alignment worked incorrectly with multiline texts.
  • 232545 DOCUMENT: Graphic Override rules did not work on the Layout for Texts and Labels placed on the Section/Elevation.
  • 241425 DOCUMENT: High resolution textures crashed renders with the internal engine.
  • 239015 DOCUMENT: Importing of the Schedule Scheme did not work correctly with user-made Option Set type Property as Criteria.
  • 235715 DOCUMENT: In certain situations, Surface Schedules could report incorrect Surface Areas for Walls with Corner Windows.
  • 239117 DOCUMENT: Interactive Schedules could give false values for the components of multiplane roofs.
  • 237507 DOCUMENT: On the Mac platform only, the layout grid combined with large scale text caused ARCHICAD to crash.
  • 238306 DOCUMENT: Some railing geometries prevented placement to layout of a View containing them.
  • 236977 DOCUMENT: The Graphic Override rules to Line Type did not work for Text Frame on the Layout.
  • 239114 DOCUMENT: The order of the items could be wrong in the Lists.
  • 235093 DOCUMENT: The pen set in use when views were created from schedules were not saved into their respective views, which later led to inconsistencies when these views were placed on layouts.
  • 236162 DOCUMENT: The renovation filter was not handled correctly with Labels originating from views on layout.
  • 237083 EDIT/MODEL: Railings end component disappeared in edit-mode.
  • 236349 EDIT/SECTION: When the section line was stretched in a plan view or in a section view, 3D information disappeared in the visible part of the section.
  • 236784 EDIT/USER INTERFACE: Stair solver had a miniature preview occasionally when editing steep stairs.
  • 234787 EDIT: 2d drafting tool polygon addition and subtraction methods failed with manual input of offsets.
  • 238867 EDIT: A Stair’s Break Mark was not present with a negative bottom offset.
  • 237899 EDIT: A mirrored dimension with custom text did not display the custom text.
  • 235528 EDIT: In some combination of the Renovation Filter, the elements with To Be Demolished or New status were not visible on the Trace.
  • 236249 EDIT: Objects didn't respect the location of the selected Anchor point.
  • 236134 EDIT: Stairs and Railings were not selected after undoing a drag-a-copy command.
  • 237431 EDIT: Stairs with" horizontal connection with bearing nibs" had incorrect offset if the "cx" value was higher than "dx".
  • 236465 EDIT: The copy operation performance needed improvement.
  • 235832 EDIT: The offset of Stair Stringers could increase randomly when the stringers were edited.
  • 242803 EDIT: The Split Tool corrupted some openings if there were both Windows and Doors in the wall.
  • 236892 EDIT: Top-linked Stairs could inherit invalid values when the Story Height was changed.
  • 238695 HOTLINK: Layer Combinations of a hotlink module file could not be appended to the host file. To enable this functionality, set the registry key HotlinkLayerCombinationEnabled to 1.
  • 232636 EDIT:Railing didn't connect correctly on slab.
  • 228848 FILE/3DS/EXPORT/GDL: The fireplace GDL objects failed to export as 3DS files, if Rendered image was set for 3D representation method.
  • 236794 FILE/3DS/Export: Wavefront files exported from ARCHICAD 21 lost material information.
  • 231178 FILE/BCF/IMPORT: BCF version 2.0 was not fully supported by the Markup tool: some of the data was lost or had an incorrect selection set.
  • 236926 FILE/BIMx/EXPORT: Hyperlinks did not work in schedules in BIMx if they were defined in ARCHICAD properties.
  • 231787 FILE/DWG/EXPORT: A PMK drawing placed on a layout with a modified boundary, incorrectly exported to DWG.
  • 231699 FILE/DWG/EXPORT: A dashed polyline with Continuous or By Segment dashing method exported incorrectly to DWG.
  • 242775 FILE/DWG/EXPORT: DWG file export caused few text fields to lose the first character.
  • 239165 FILE/GSM,RFA/IMPORT: Certain objects were displayed in different ways in ARCHICAD if they were placed using their .GSM or .RFA format.
  • 240778 FILE/IFC/EXPORT/CRASH: ARCHICAD Some skylight geometries were incorrectly handled as part of Zone update and IFC export.
  • 237848 FILE/IFC/EXPORT/CRASH: Opening the IFC translators for export crashed ARCHICAD under certain circumstances.
  • 232310 FILE/IFC/EXPORT: A project with a migrated v20 Stairmaker stair failed to export to IFC.
  • 236257 FILE/IFC/EXPORT: ARCHICAD crashed during IFC export, if Trace was active and ARCHICAD windows were switched.
  • 237166 FILE/IFC/EXPORT: Classification of elements that were parts of a Hotlinked Module were lost in the exported IFC file.
  • 241278 FILE/IFC/EXPORT: Exported IFC files contained duplicate GUIDs.
  • 228451 FILE/IFC/EXPORT: IFC exports failed to address negative values of reveal depth of door or window.
  • 231038 FILE/IFC/IMPORT: IFCBeams, in certain cases, received an offset after import.
  • 236959 FILE/KZM/EXPORT: ARCHICAD textures were missing in Google Earth if the texture name contained certain national language characters.
  • 236146 FILE/OPEN/CRASH: ARCHICAD did not robustly handle optional attributes in IFC files.
  • 241751 FILE/OPEN: On the Mac platform, if a file server to external links was not available, an error dialog of the form: There was a problem connecting to the server..." was emitted. This dialog has been disabled since it caused significant delays, and duplicated information in other dialogs.
  • 236714 FILE/PDF/EXPORT: Exported Zones appeared with a blue transparent fill in Bluebeam Revu on Mac.
  • 238032 FILE/PDF/EXPORT/IMPORT: Bluebeam markups imported to ARCHICAD had an offset.
  • 236599 FILE/SKP/EXPORT/IMPORT: Imported Sketchup models with KME library (Netherlands) had incorrect dimensions.
  • 235497 FILE/XLSX/EXPORT: Uniform items that were merged in Interactive Schedules were extracted into individual items when Property Values were exported from the Schedule. This led to large sheets of data that were difficult to work with.
  • 193670 FREEZE: ARCHICAD could freeze in the Composite Structures Dialog, if a certain Line Types in a Composite was used.
  • 233123 GDL/CRASH: ARCHICAD crashed when stair starts with tread, has a vertical run-start connection and walking line offset is on.
  • 231870 GDL/DOCUMENT: The preview pictures of custom GDL Elements didn't appear in schedules if they were password protected.
  • 237380 GDL: The APPLICATION_QUERY command returned no value when used with Stairs and Railings.
  • 234303 GDL: The process of removing an Embedded Library could take over an hour.
  • 241375 GOOGLE EARTH: ARCHICAD was unable to connect to Google Earth on OS X.
  • 232714 GRASSHOPPER: ARCHICAD incorrectly exported Elevation information to Rhino-Grashopper
  • 240889 HOTLINK/CRASH: ARCHICAD crashed when placing a hotlink into a file that contained corrupted stairs.
  • 238618 HOTLINK: Due to changes in file handling under macOS 10.13 it was not possible to Hotlink a file that was open by a different user.
  • 239421 HOTLINK: Elements were lost in copies of hotlinks created with drag a copy.
  • 238695 HOTLINK: Layer Combinations of a hotlink module file could not be appended to the host file. To enable this functionality, set the registry key HotlinkLayerCombinationEnabled to 1.
  • 235794 LICENSING: ARCHICAD on computers with Apple Fusion Drive frequently after a reboot requested the user accept again the End User License Agreement (EULA).
  • 239392 MODEL: An ellipse transformed to a circle when arrows were added.
  • 232314 MODEL: Custom railing panels and posts were rotated by 90 degrees when placed with the Railing tool.
  • 205709 MODEL: Custom Symbol Fills made of circles did not appear properly.
  • 237138 MODEL: Doors and Windows did not snap to Wall intersections.
  • 236789 MODEL: End plate of stairs had huge offset after reopening the plan.
  • 238997 MODEL: Grasshopper elements classified as 'closed planar curves' connected to ARCHICAD components could crash Rhino as part of the process of sending to ARCHICAD.
  • 237042 MODEL: If the "use break mark settings of associated stairs" option was disabled the railing could display incorrectly.
  • 237106 MODEL: If the riser gap of the stair was set to 0, there still was a small gap between the riser and the structure.
  • 238062 MODEL: It was not possible to abort the 3D generation: 'Click to abort' button had no effect.
  • 237067 MODEL: Model View Options of Stairs had an effect on Model View Options of Openings.
  • 239012 MODEL: Modifications to a stair with “Winder with equal angles/goings" turning type often resulted in its dimensions being lost.
  • 235823 MODEL: Morph editing in section created an invalid offset.
  • 223433 MODEL: Saved Zoom could be missing from the View Settings.
  • 198622 MODEL: Surface painter overrode all surfaces even if only one surface was selected to be overridden.
  • 236499 MODEL: The elements the railing tool created ignored the cut line and were shown on layout even when they should not have.
  • 236390 MODEL: The horizontal drag in Section/Elevation of a Door/Window with manual input gave unexpected results.
  • 238252 MODEL: The same Stair saved as a Favorite could be different depending on from where it was saved.
  • 239006 MODEL: Undo failed with stair baseline edits.
  • 235758 MODEL: Zones were not processed correctly with certain cutting operations that led to visibilities issues in the perspective view.
  • 236706 MODEL: When the inner posts of a railing were removed, the railing panels lost their assigned orientation.
  • 238083 RAILING/CRASH: ARCHICAD crashed when placing Railing on a Stair if the hotlinked modul contained embedded library.
  • 247437 SPEED: ARCHICAD was becoming slower and slower the more detail/documentation was produced.
  • 227943 STAIR/CRASH: ARCHICAD could crash if a Stair started with a Landing and the first Stair flight started with a Tread instead of a Riser.
  • 236932 STAIR/CRASH: ARCHICAD crashed during Background updating because of a bug in the Landing-Run connections when the landing was monolithic and the run was a straight beam support structure.
  • 240232 STAIR/FAVORITES: 2D previews of the stair favorites were missing in some cases.
  • 237403 STAIR/PREVIEW: The 3D preview of the tread and riser settings froze for certain localizations.
  • 236526 STAIR: Associative railings with offset had missing geometry and long segments.
  • 231069 STAIR: Handrail left side selection was not saved without a horizontal offset value.
  • 235333 USER INTERFACE/CRASH: ARCHICAD slowed down and could crash when Trace and Reference was switched on and the Renovation Palette was open.
  • 241473 USER INTERFACE/FREEZE: Severe lag during user interaction when Favorite Palette was open.
  • 237195 USER INTERFACE: ARCHICAD on macOS 10.13 could perform slowly, with some operations that relied heavily on the creation of temporary folders (such as library object handling).
  • 239745 USER INTERFACE: ARCHICAD slowed down on Windows when the computer had not restarted for a while.
  • 234757 USER INTERFACE: SiteMaker's Opening Coordinate File dialog displayed incorrect Japanese characters.
  • 241935 USER INTERFACE: The list menu in favorites for different tools was unavailable on macOS 10.13.
  • 241816 USER INTERFACE: The localized RUS Version had a cosmetic error with a schedule dialog button.
  • 241225 USER INTERFACE: Typically on 4k monitors that were scaled up on Windows, a cursor could be offset from the model element it was referencing.

New in ArchiCAD 21 Build 6000 Update (Mar 28, 2018)

  • 240314 BIMcloud / BIM Server: The critical.log was not created in some circumstances.
  • 235032 CRASH: The PolyCount could fail to calculate the polygons of stairs and occasionally it crashed.
  • 235765 DOCUMENT: An object belonging to more than one Zone with each Zone having a different Renovation status could report an incorrect related Zone number and name in a schedule.
  • 234196 DOCUMENT: Dimensions were sometimes temporarily lost on the Floor Plan when switching to Section/Elevation and back.
  • 233995 DOCUMENT: Doors were not considered to belong to a zone, if they were inside it, not on its edge.
  • 232545 DOCUMENT: Graphic Override rules did not work on the Layout for Texts and Labels placed on the Section/Elevation.
  • 241425 DOCUMENT: High resolution textures crashed renders with the internal engine.
  • 239015 DOCUMENT: Importing of the Schedule Scheme did not work correctly with user-made Option Set type Property as Criteria.
  • 235715 DOCUMENT: In certain situations, Surface Schedules could report incorrect Surface Areas for Walls with Corner Windows.
  • 239117 DOCUMENT: Interactive Schedules could give false values for the components of multiplane roofs.
  • 237507 DOCUMENT: On the Mac platform only, the layout grid combined with large scale text caused ARCHICAD to crash.
  • 236977 DOCUMENT: The Graphic Override rules to Line Type did not work for Text Frame on the Layout.
  • 239114 DOCUMENT: The order of the items could be wrong in the Lists.
  • 236249 EDIT: Objects didn't respect the location of the selected Anchor point.
  • 236134 EDIT: Stairs and Railings were not selected after undoing a drag-a-copy command.
  • 235832 EDIT: The offset of Stair Stringers could increase randomly when the stringers were edited.
  • 242803 EDIT: The Split Tool corrupted some openings if there were both Windows and Doors in the wall.
  • 236892 EDIT: Top-linked Stairs could inherit invalid values when the Story Height was changed.
  • 236349 EDIT/SECTION: When the section line was stretched in a plan view or in a section view, 3D information disappeared in the visible part of the section.
  • 236794 FILE/3DS/Export: Wavefront files exported from ARCHICAD 21 lost material information.
  • 231178 FILE/BCF/IMPORT: BCF version 2.0 was not fully supported by the Markup tool: some of the data was lost or had an incorrect selection set.
  • 236926 FILE/BIMx/EXPORT: Hyperlinks did not work in schedules in BIMx if they were defined in ARCHICAD properties.
  • 231699 FILE/DWG/EXPORT: A dashed polyline with Continuous or By Segment dashing method exported incorrectly to DWG.
  • 239165 FILE/GSM,RFA/IMPORT: Certain objects were displayed in different ways in ARCHICAD if they were placed using their .GSM or .RFA format.
  • 232310 FILE/IFC/EXPORT: A project with a migrated v20 Stairmaker stair failed to export to IFC.
  • 237166 FILE/IFC/EXPORT: Classification of elements that were parts of a Hotlinked Module were lost in the exported IFC file.
  • 236959 FILE/KZM/EXPORT: ARCHICAD textures were missing in Google Earth if the texture name contained certain national language characters.
  • 237380 GDL: The APPLICATION_QUERY command returned no value when used with Stairs and Railings.
  • 231870 GDL/DOCUMENT: The preview pictures of custom GDL Elements didn't appear in schedules if they were password protected.
  • 232714 GRASSHOPPER: ARCHICAD incorrectly exported Elevation information to Rhino-Grashopper
  • 232314 MODEL: Custom railing panels and posts were rotated by 90 degrees when placed with the Railing tool.
  • 237138 MODEL: Doors and Windows did not snap to Wall intersections.
  • 236789 MODEL: End plate of stairs had huge offset after reopening the plan.
  • 238997 MODEL: Grasshopper elements classified as 'closed planar curves' connected to ARCHICAD components could crash Rhino as part of the process of sending to ARCHICAD.
  • 238062 MODEL: It was not possible to abort the 3D generation: 'Click to abort' button had no effect.
  • 237067 MODEL: Model View Options of Stairs had an effect on Model View Options of Openings.
  • 235823 MODEL: Morph editing in section created an invalid offset.
  • 223433 MODEL: Saved Zoom could be missing from the View Settings.
  • 236390 MODEL: The horizontal drag in Section/Elevation of a Door/Window with manual input gave unexpected results.
  • 238252 MODEL: The same Stair saved as a Favorite could be different depending on from where it was saved.
  • 236526 STAIR: Associative railings with offset had missing geometry and long segments.
  • 231069 STAIR: Handrail left side selection was not saved without a horizontal offset value.
  • 240232 STAIR/FAVORITES: 2D previews of the stair favorites were missing in some cases.
  • 237403 STAIR/PREVIEW: The 3D preview of the tread and riser settings froze for certain localizations.
  • 236312 TEAMWORK / CRASH: Library synchronization with stairs elements was not handled robustly.
  • 232687 TEAMWORK: "Damaged project" error message could appear with the GER version ARCHICAD client that had been updated and the BIM Server still was using the original release version.
  • 234963 TEAMWORK: A newly created detail from a new section and subsequently opened by a different user caused a crash.
  • 239332 TEAMWORK: If an auto-saved version of a teamwork project was opened it was possible un-reserved gdl based objects, such as doors, windows or markers could break the send&receive process.
  • 236370 TEAMWORK: Previously deleted 3D Styles set in another user's 3D window broke the Send & Receive process.
  • 243512 TEAMWORK/DOCUMENT: Dimensions changed to Custom were not correctly displayed on other teammateís displays.
  • 242346 TEAMWORK/DOCUMENT: The display did not refresh after receiving modifications of the Dimension Text.
  • 239745 USER INTERFACE: ARCHICAD slowed down on Windows when the computer had not restarted for a while.
  • 234757 USER INTERFACE: SiteMaker's Opening Coordinate File dialog displayed incorrect Japanese characters.
  • 241225 USER INTERFACE: Typically on 4k monitors that were scaled up on Windows, a cursor could be offset from the model element it was referencing.
  • 235333 USER INTERFACE/CRASH: ARCHICAD slowed down and could crash when Trace and Reference was switched on and the Renovation Palette was open.
  • 241473 USER INTERFACE/FREEZE: Severe lag during user interaction when Favorite Palette was open.

New in ArchiCAD 21 Build 5024 Update (Feb 22, 2018)

  • New Features:
  • PDF Reviewer Tool connection (e.g. Adobe Acrobat, Bluebeam etc.)
  • With this solution, we provide a complete, bi-directional workflow between ARCHICAD and any standard PDF reviewer tool, such as Adobe Acrobat or Bluebeam. The solution improves communication and collaboration among architects, engineers and other project stakeholders during PDF-based project management. Bi-directional means that all the markups created in the PDF editor can be imported back to ARCHICAD, where they are transformed into Markup entries which appear in the correct location, helping the user to understand and solve the issue.
  • Bluebeam Reviewer Tool connection (add-on product, part of US only)
  • This is an additional palette for the general PDF Reviewer Tool connection which contains the most important commands for bi-directional workflow between ARCHICAD and Bluebeam only.
  • Bugfixes:
  • CRASH: In certain cases, ARCHICAD crashed when a user opened a project and tried to move something.
  • CRASH: Certain default settings of the Railing Tool's Ends made it impossible to place the Railing and caused a crash.
  • CRASH: In certain cases, the SwissTools Add-on caused ARCHICAD to crash.
  • DOCUMENT/IES: The Interactive Schedule format of feet & fractional inch values was incorrect.
  • DOCUMENT: Bitmap objects did not align to the camera in perspective view.
  • DOCUMENT: Custom Drawing Titles could end up displaying the names of all drawings placed on the layout when published.
  • DOCUMENT: Interactive Schedule add-on terminated with criteria that used the “Allow Multiple Choices” parameter.
  • DOCUMENT: It was not possible to edit the integer type custom properties in Interactive Element Schedule.
  • DOCUMENT: Sections, Elevations and other Views could appear on the layout with a rotation.
  • DOCUMENT: Several Skins of Composite Structure were merged into one Skin in 2D Plan Preview of Schedules.
  • DOCUMENT: Some drawings' status reverted back to "Needs checking" after updating them.
  • DOCUMENT: The overridden color of the floor plan view of a stair was displayed wrong on layout.
  • DOCUMENT: The position of the Dimension Text Anchor could not be changed from the pop-up menu.
  • DOCUMENT: Using undo command after Layout creation led to ARCHICAD crashing upon opening the Change Manager.
  • DOCUMENT/CRASH: ARCHICAD could crash at Layout update because of an incorrect Railing.
  • EDIT/CRASH: ARCHICAD crashed if a schedule listed a stair which had a missing stringer profile.
  • EDIT/CRASH: ARCHICAD crashed in some projects with meshes when sea level data was changed in the Project Info dialog.
  • 232818 EDIT/CRASH: ARCHICAD crashed when editing a Curtain Wall with missing Panel Building Material.
  • EDIT/FREEZE: During property transfer using syringe/pipette ARCHICAD became unresponsive, if the find and select dialog was open.
  • EDIT/RAILING: If a railing was placed with a special method ARCHICAD could crash.
  • EDIT/STAIR/CRASH: ARCHICAD crashed with stairs that had their boundary edited in the 3d window.
  • EDIT/STAIR: Moving stair with Marquee stretch was not achievable.
  • EDIT/STAIR: Stairs in Story View had incorrect contour lines.
  • EDIT: Adjust command did not work to extend a polyline.
  • EDIT: Classifications and properties of elements could go missing in certain files when they were opened in ARCHICAD 21.
  • EDIT: Grid System didn't recognize Russian characters, instead it showed "?" on windows or an empty box on Mac.
  • EDIT: Guideline grips were not available when Renovation Pallet was open, also Renovation Pallet was flickering from time to time.
  • EDIT: If Graphic Override Rule contained Composite as criteria, the previously selected value went missing.
  • EDIT: Graphical Overrides did not robustly work together with the Renovation filter. During drawing update Renovation filter labeled New elements could be confused with Existing elements.
  • EDIT: Stair stringer or beam was not involved in SEO as operator element.
  • EDIT: The Special Distribute function did not evenly distribute elements along a circle. Instead it placed them all in one spot.
  • EDIT: When the Multiply command was used in 3D with Doors and Windows the resulting distance was incorrect.
  • EXPORT: It was not possible to export separate elements of the stairs using "Folder" export.
  • FILE/DXF/EXPORT: XTMIN, XTMAX values were not exported correctly to DXF.
  • FILE/DXF/IMPORT: In certain cases, DXF files could not be imported to ARCHICAD.
  • FILE/OPEN: Open&Repair was made more robust.
  • GDL: Manual Texture mapping (eg. with TEVE commands) could fail if the Object was mirrored.
  • HIGH SIERRA: Opening the Push menu from a toolbar was crashing ARCHICAD.
  • HIGH SIERRA: Contents of the 3D window froze when switching between 3D Styles.
  • HIGH SIERRA: Contents of the 2D window froze after turning the 2D Hardware Acceleration off.
  • LEARNING: YouTube Channels and Online Training of different ARCHICAD versions could not be used at the same time.
  • MODEL/CRASH: The process of converting certain material settings to the current CineRender level crashed ARCHICAD.
  • MODEL/RAILING: Curved panels could fail to create even with 90° skewed angle.
  • MODEL/RAILING: Railings could appear in floor plans even if they were out of range.
  • MODEL/ZONE: Zone Number could display incorrectly in custom Zone Stamps.
  • MODEL: A window with masonry arch was incorrectly displayed in 2d if a beam that was part of the wall the window was placed in had been used to define the hole in the wall with an SEO.
  • MODEL: Projected 2D Floor Plan view of Doors/Windows used the wrong fill type and pens.
  • MODEL: Sections could fail to generate content if there were overlapping breakpoints in the Section Line.
  • MODEL: Sometimes certain segments of Railings were displayed with the wrong pens and line types on the floor plan.
  • MODEL: The splitting of Roofs/Slabs/Beams, which are set to show on "All Stories", result in parts with different "Show on Stories" settings.
  • STAIR: Anytime the settings of a placed stair was opened and closed, the stair shrank with the value of the Baseline offset parameter.
  • STAIR: Magic Wand preselection didn't work with the Stair Tool.
  • STAIR: Modifications set in the Riser Settings info box were not applied to the Riser.

New in ArchiCAD 21 Build 5021 Update (Feb 7, 2018)

  • This Update addresses the issue of disappearing Stairs on Floor Plans. This Update contains many improvements since the original release of ARCHICAD 21. ARCHICAD and BIM Server are Updated with two separate packages. The ARCHICAD package can be used to update ARCHICAD and the installed GRAPHISOFT Add-Ons and Goodies, while the BIM Server package can update the installed BIM Server only.

New in ArchiCAD 21 Build 5010 Update (Dec 13, 2017)

  • Bugfixes:
  • 229932 CRASH: In certain cases, ARCHICAD crashed when a user opened a project and tried to move something.
  • 232799 CRASH: Certain default settings of the Railing Tool's Ends made it impossible to place the Railing and caused a crash.
  • 231023 CRASH: In certain cases, the SwissTools Add-on caused ARCHICAD to crash.
  • 230091 DOCUMENT/IES: The Interactive Schedule format of feet & fractional inch values was incorrect.
  • 192062 DOCUMENT: Bitmap objects did not align to the camera in perspective view.
  • 235305 DOCUMENT: Custom Drawing Titles could end up displaying the names of all drawings placed on the layout when published.
  • 233786 DOCUMENT: Interactive Schedule add-on terminated with criteria that used the “Allow Multiple Choices” parameter.
  • 233090 DOCUMENT: It was not possible to edit the integer type custom properties in Interactive Element Schedule.
  • 202366 DOCUMENT: Sections, Elevations and other Views could appear on the layout with a rotation.
  • 220598 DOCUMENT: Several Skins of Composite Structure were merged into one Skin in 2D Plan Preview of Schedules.
  • 234561 DOCUMENT: Some drawings' status reverted back to "Needs checking" after updating them.
  • 231510 DOCUMENT: The overridden color of the floor plan view of a stair was displayed wrong on layout.
  • 232709 DOCUMENT: The position of the Dimension Text Anchor could not be changed from the pop-up menu.
  • 231954 DOCUMENT: Using undo command after Layout creation led to ARCHICAD crashing upon opening the Change Manager.
  • 232096 DOCUMENT/CRASH: ARCHICAD could crash at Layout update because of an incorrect Railing.
  • 232815 EDIT/CRASH: ARCHICAD crashed if a schedule listed a stair which had a missing stringer profile.
  • 233682 EDIT/CRASH: ARCHICAD crashed in some projects with meshes when sea level data was changed in the Project Info dialog.
  • 232818 EDIT/CRASH: ARCHICAD crashed when editing a Curtain Wall with missing Panel Building Material.
  • 233845 EDIT/FREEZE: During property transfer using syringe/pipette ARCHICAD became unresponsive, if the find and select dialog was open.
  • 234904 EDIT/RAILING: If a railing was placed with a special method ARCHICAD could crash.
  • 234914 EDIT/STAIR/CRASH: ARCHICAD crashed with stairs that had their boundary edited in the 3d window.
  • 231834 EDIT/STAIR: Moving stair with Marquee stretch was not achievable.
  • 222627 EDIT/STAIR: Stairs in Story View had incorrect contour lines.
  • 231243 EDIT: Adjust command did not work to extend a polyline.
  • 232759 EDIT: Classifications and properties of elements could go missing in certain files when they were opened in ARCHICAD 21.
  • 231213 EDIT: Grid System didn't recognize Russian characters, instead it showed "?" on windows or an empty box on Mac.
  • 232967 EDIT: Guideline grips were not available when Renovation Pallet was open, also Renovation Pallet was flickering from time to time.
  • 235557 EDIT: If Graphic Override Rule contained Composite as criteria, the previously selected value went missing.
  • 231695 EDIT: Graphical Overrides did not robustly work together with the Renovation filter. During drawing update Renovation filter labeled New elements could be confused with Existing elements.
  • 232003 EDIT: Stair stringer or beam was not involved in SEO as operator element.
  • 232395 EDIT: The Special Distribute function did not evenly distribute elements along a circle. Instead it placed them all in one spot.
  • 231625 EDIT: When the Multiply command was used in 3D with Doors and Windows the resulting distance was incorrect.
  • 234545 EXPORT: It was not possible to export separate elements of the stairs using "Folder" export.
  • 234857 FILE/C4D/EXPORT: After saving a c4d file, the texture folder could go missing when the Photorendering Settings Palette was closed.
  • 166837 FILE/DXF/EXPORT: XTMIN, XTMAX values were not exported correctly to DXF.
  • 232525 FILE/DXF/IMPORT: In certain cases, DXF files could not be imported to ARCHICAD.
  • 231828 FILE/OPEN: Open&Repair was made more robust.
  • 232791 FILE/TEMPLATE: The default font was missing in the default template file in ARCHICAD 21 CZE on macOS.
  • 232152 FILE/TEMPLATE: The default font was missing in the default template file in ARCHICAD 21 HUN on macOS.
  • 229701 GDL: Manual Texture mapping (eg. with TEVE commands could fail if the Object was mirrored.
  • 234395 HIGH SIERRA: Opening the Push menu from a toolbar was crashing ARCHICAD.
  • 232905 HIGH SIERRA: Contents of the 3D window froze when switching between 3D Styles.
  • 232873 HIGH SIERRA: Contents of the 2D window froze after turning the 2D Hardware Acceleration off.
  • 226969 HOTLINK: Elevation value in Hotlink Module Settings dialog was referring to different home story in case of placing multilevel hotlink.
  • 232412 HOTLINK: Zones coming from hotlink modules were not listed in schedules if Any Hotlink was chosen in Hotlinked Module criteria.
  • 231987 LEARNING: YouTube Channels and Online Training of different ARCHICAD versions could not be used at the same time.
  • 229696 MODEL/CRASH: The process of converting certain material settings to the current CineRender level crashed ARCHICAD.
  • 233437 MODEL/RAILING: Curved panels could fail to create even with 90° skewed angle.
  • 233547 MODEL/RAILING: Railings could appear in floor plans even if they were out of range.
  • 232631 MODEL/ZONE: Zone Number could display incorrectly in custom Zone Stamps.
  • 233929 MODEL: A window with masonry arch was incorrectly displayed in 2d if a beam that was part of the wall the window was placed in had been used to define the hole in the wall with an SEO.
  • 227957 MODEL: Projected 2D Floor Plan view of Doors/Windows used the wrong fill type and pens.
  • 233689 MODEL: Sections could fail to generate content if there were overlapping breakpoints in the Section Line.
  • 234571 MODEL: Sometimes certain segments of Railings were displayed with the wrong pens and line types on the floor plan.
  • 231509 MODEL: The splitting of Roofs/Slabs/Beams, which are set to show on "All Stories", result in parts with different "Show on Stories" settings.
  • 233058 STAIR: Anytime the settings of a placed stair was opened and closed, the stair shrank with the value of the Baseline offset parameter.
  • 235430 STAIR: Magic Wand preselection didn't work with the Stair Tool.
  • 234884 STAIR: Modifications set in the Riser Settings info box were not applied to the Riser.
  • 231930 VIEW/3D: In the Russian localization of ARCHICAD the 3D Navigation mode hotkeys "W", "A", "S", "D" did not work.

New in ArchiCAD 21 Build 5002 Update (Nov 6, 2017)

  • NEW FEATURES:
  • PDF Reviewer Tool connection (e.g. Adobe Acrobat, Bluebeam etc.):
  • With this solution, we provide a complete, bi-directional workflow between ARCHICAD and any standard PDF reviewer tool, such as Adobe Acrobat or Bluebeam. The solution improves communication and collaboration among architects, engineers and other project stakeholders during PDF-based project management. Bi-directional means that all the markups created in the PDF editor can be imported back to ARCHICAD, where they are transformed into Markup entries which appear in the correct location, helping the user to understand and solve the issue.
  • Link Rhino (.3dm):
  • We have further improved collaboration between ARCHICAD and Rhinoceros – a popular free-form modelling tool – by adding new import options. The user can link Rhino source files (.3dm) into ARCHICAD, and update, relink etc. in the usual way, similarly to the Link IFC feature introduced in ARCHICAD 21.
  • Also, Rhino files can be imported into ARCHICAD as an Object, so the new command directly imports Rhino models into ARCHICAD’s Embedded Library as a GDL Object. This command replaces the "Rhino-GDL Converter" add-on, released for ARCHICAD 18, 19 and 20.
  • Bluebeam Reviewer Tool connection (add-on product, part of US only):
  • This is an additional palette for the general PDF Reviewer Tool connection which contains the most important commands for bi-directional workflow between ARCHICAD and Bluebeam only.
  • BUG FIXES:
  • 232173 BIM Server/BIMcloud/HELP: The Help for BIM Server 21/BIMcloud 21 (German version) was linked to the Help Center article of BIM Server 20 and BIMcloud 20.
  • 232940 BIM Server: BIM Server activation failed due to a connection error.
  • 235201 BIMcloud/BIM Server: Black screen occurred for an indeterminate time after restart or shutdown command on macOS 10.13 High Sierra.
  • 234626 BIMcloud: While copying elements within the same project a user who had not been granted rights to create attributes was confronted with a dialog that falsely indicated some copied elements might refer to “MISSING” attributes.
  • 228927 BIMcloud: Manager incorrectly displayed "not set" for a default host server.
  • 229932 CRASH: In certain cases, ARCHICAD crashed when a user opened a project and tried to move something.
  • 232799 CRASH: Certain default settings of the Railing Tool's Ends made it impossible to place the Railing and caused a crash.
  • 231023 CRASH: In certain cases, the SwissTools Add-on caused ARCHICAD to crash.
  • 230091 DOCUMENT/IES: The Interactive Schedule format of feet & fractional inch values was incorrect.
  • 192062 DOCUMENT: Bitmap objects did not align to the camera in perspective view.
  • 235305 DOCUMENT: Custom Drawing Titles could end up displaying the names of all drawings placed on the layout when published.
  • 233786 DOCUMENT: Interactive Schedule add-on terminated with criteria that used the “Allow Multiple Choices” parameter.
  • 233090 DOCUMENT: It was not possible to edit the integer type custom properties in Interactive Element Schedule.
  • 202366 DOCUMENT: Sections, Elevations and other Views could appear on the layout with a rotation.
  • 220598 DOCUMENT: Several Skins of Composite Structure were merged into one Skin in 2D Plan Preview of Schedules.
  • 234561 DOCUMENT: Some drawings' status reverted back to "Needs checking" after updating them.
  • 231510 DOCUMENT: The overridden color of the floor plan view of a stair was displayed wrong on layout.
  • 232709 DOCUMENT: The position of the Dimension Text Anchor could not be changed from the pop-up menu.
  • 231954 DOCUMENT: Using undo command after Layout creation led to ARCHICAD crashing upon opening the Change Manager.
  • 232096 DOCUMENT/CRASH: ARCHICAD could crash at Layout update because of an incorrect Railing.
  • 232815 EDIT/CRASH: ARCHICAD crashed if a schedule listed a stair which had a missing stringer profile.
  • 233682 EDIT/CRASH: ARCHICAD crashed in some projects with meshes when sea level data was changed in the Project Info dialog.
  • 232818 EDIT/CRASH: ARCHICAD crashed when editing a Curtain Wall with missing Panel Building Material.
  • 233845 EDIT/FREEZE: During property transfer using syringe/pipette ARCHICAD became unresponsive, if the find and select dialog was open.
  • 234904 EDIT/RAILING: If a railing was placed with a special method ARCHICAD could crash.
  • 234914 EDIT/STAIR/CRASH: ARCHICAD crashed with stairs that had their boundary edited in the 3d window.
  • 231834 EDIT/STAIR: Moving stair with Marquee stretch was not achievable.
  • 222627 EDIT/STAIR: Stairs in Story View had incorrect contour lines.
  • 231243 EDIT: Adjust command did not work to extend a polyline.
  • 232759 EDIT: Classifications and properties of elements could go missing in certain files when they were opened in ARCHICAD 21.
  • 231213 EDIT: Grid System didn't recognize Russian characters, instead it showed "?" on windows or an empty box on Mac.
  • 232967 EDIT: Guideline grips were not available when Renovation Pallet was open, also Renovation Pallet was flickering from time to time.
  • 235557 EDIT: If Graphic Override Rule contained Composite as criteria, the previously selected value went missing.
  • 231695 EDIT: Graphical Overrides did not robustly work together with the Renovation filter. During drawing update Renovation filter labeled New elements could be confused with Existing elements.
  • 232003 EDIT: Stair stringer or beam was not involved in SEO as operator element.
  • 232395 EDIT: The Special Distribute function did not evenly distribute elements along a circle. Instead it placed them all in one spot.
  • 231625 EDIT: When the Multiply command was used in 3D with Doors and Windows the resulting distance was incorrect.
  • 234545 EXPORT: It was not possible to export separate elements of the stairs using "Folder" export.
  • 234857 FILE/C4D/EXPORT: After saving a c4d file, the texture folder could go missing when the Photorendering Settings Palette was closed.
  • 166837 FILE/DXF/EXPORT: XTMIN, XTMAX values were not exported correctly to DXF.
  • 232525 FILE/DXF/IMPORT: In certain cases, DXF files could not be imported to ARCHICAD.
  • 231828 FILE/OPEN: Open&Repair was made more robust.
  • 232791 FILE/TEMPLATE: The default font was missing in the default template file in ARCHICAD 21 CZE on macOS.
  • 232152 FILE/TEMPLATE: The default font was missing in the default template file in ARCHICAD 21 HUN on macOS.
  • 229701 GDL: Manual Texture mapping (eg. with TEVE commands) could fail if the Object was mirrored.
  • 226969 HOTLINK: Elevation value in Hotlink Module Settings dialog was referring to different home story in case of placing multilevel hotlink.
  • 232412 HOTLINK: Zones coming from hotlink modules were not listed in schedules if Any Hotlink was chosen in Hotlinked Module criteria.
  • 231987 LEARNING: YouTube Channels and Online Training of different ARCHICAD versions could not be used at the same time.
  • 229696 MODEL/CRASH: The process of converting certain material settings to the current CineRender level crashed ARCHICAD.
  • 233437 MODEL/RAILING: Curved panels could fail to create even with 90° skewed angle.
  • 233547 MODEL/RAILING: Railings could appear in floor plans even if they were out of range.
  • 232631 MODEL/ZONE: Zone Number could display incorrectly in custom Zone Stamps.
  • 233929 MODEL: A window with masonry arch was incorrectly displayed in 2d if a beam that was part of the wall the window was placed in had been used to define the hole in the wall with an SEO.
  • 227957 MODEL: Projected 2D Floor Plan view of Doors/Windows used the wrong fill type and pens.
  • 233689 MODEL: Sections could fail to generate content if there were overlapping breakpoints in the Section Line.
  • 234571 MODEL: Sometimes certain segments of Railings were displayed with the wrong pens and line types on the floor plan.
  • 231509 MODEL: The splitting of Roofs/Slabs/Beams, which are set to show on "All Stories", result in parts with different "Show on Stories" settings.
  • 233058 STAIR: Anytime the settings of a placed stair was opened and closed, the stair shrank with the value of the Baseline offset parameter.
  • 235430 STAIR: Magic Wand preselection didn't work with the Stair Tool.
  • 234884 STAIR: Modifications set in the Riser Settings info box were not applied to the Riser.
  • 232766 TEAMWORK/BIMcloud: The Change Host function was not available if any listed BIMcloud Server was “Not Accessible”.
  • 231586 TEAMWORK/BIMcloud: BIMcloud User Licenses could not be released automatically if there was a CodeMeter error during the process.
  • 233389 TEAMWORK/BIMcloud: Project status stuck on 'maintenance' because of Mailboxes.db corruption.
  • 232318 TEAMWORK/CRASH: Changes to a teamwork project in the 3d window crashed ARCHICAD under certain circumstances when a pop-up dialog was necessary.
  • 233312 TEAMWORK/CRASH: Project migration crashed under certain circumstances.
  • 232738 TEAMWORK/EDIT: Deleting or modifying Interior Elevations was causing a local cache corruption.
  • 233299 TEAMWORK/FREEZE: Project migration had a non-responsive period without a progress dialog that increased with the number of projects that had been prepared.
  • 228940 TEAMWORK: Did not fully support TLS 1.2.
  • 234927 TEAMWORK: ARCHICAD login with case insensitive username caused errors with TW operations.
  • 231930 VIEW/3D: In the Russian localization of ARCHICAD the 3D Navigation mode hotkeys "W", "A", "S", "D" did not work.

New in ArchiCAD 21 Build 4023 Update (Oct 2, 2017)

  • This Update contains various enhancements and fixes since the original release of ARCHICAD 21 Solo:
  • 229994 CRASH: A large number of point cloud objects caused ARCHICAD to crash in the 3D Window.
  • 229639 DOCUMENT: It was not possible to filter out Doors/Windows and Skylights from the Material List in Component Schedules. The material of these elements appeared as Dotted Lines in the Schedule.
  • 225619 DOCUMENT/LABEL: It was not possible get the percentage of the slope of the roof with the label tool.
  • 230110 EDIT: Door/Window Oversize changes didn't apply on Section/Elevation Views.
  • 228570 EDIT: Drag command did not work on Views in Layout when clicking on Drawing's subelement Fill's hole edge/corner.
  • 229252 EDIT/FAVORITE: Applying a Door/Window Favorite did not apply its Sill Height.
  • 229250 EDIT/FAVORITE: Position and Structural Function category was not saved along with the Favorites.
  • 228038 EDIT/USER INTERFACE: Stair Favorite preview went wrong after selecting the stair symbol parameter set.
  • 229769 FILE/3DS/IMPORT: Prism panels moved away from each other, when the 2D view was not on their Home Story and their originating curves were changed in Rhino.
  • 214001 FILE/BCF/EXPORT: Exporting a BCF file with rotated orientation would result in a wrong camera position in other applications.
  • 230733 FILE/BIMx: Once a password was set for a BIMx publisher set, it could not be removed.
  • 230058 FILE/BIMx/EXPORT: BIMx Hyper-model export could take significantly longer if Categories and Properties were included as the Info Set.
  • 230465 FILE/EXCEL/EXPORT: From Schedules, decimals in superscript could export as wholes into Excel.
  • 230043 FILE/IFC/EXPORT: IfcTypes didn’t work for Pipe Segments and Cable Carrier Segments.
  • 228613 FILE/IFC/EXPORT: In certain cases some Walls were missing from the exported IFC.
  • 226620 FILE/IFC/EXPORT: Some elements could go missing in the exported IFC file if they originated from an IFC file as well.
  • 229954 FILE/IFC/EXPORT/CRASH: ARCHICAD 21 could crash when saving IFC file with wrong Type Mapping.
  • 211307 FILE/IFC/IMPORT: Importing an IFC file could result in an empty ARCHICAD project in certain cases, even though the IFC file could be displayed in other IFC viewer applications.
  • 229463 FILE/IFC/OPEN: It was not possible to open/merge a certain IFC file.
  • 228064 FILE/MODEL/CRASH: Temporary files created from Point Clouds highly decreased the free space of the hard drive, which led ARCHICAD to crash.
  • 228760 FILE/OPEN: Missing Cadimage Add-on data could not be deleted from a project by unticking the "Keep Data" checkbox upon opening the ARHICAD file.
  • 220050 FILE/OPEN/CRASH: ARCHICAD could crash at startup if the last used User Profile contained the IFC Manager palette opened.
  • 229701 GDL: Manual Texture mapping (eg. with TEVE commands) could fail if the Object was mirrored.
  • 228045 GOODIES: Check for Duplicates add-on identified non-duplicated Morph elements as duplicates.
  • 167412 GOODIES: Construction Simulation: If Caption object was used for the movie, it was displayed in wrong scale.
  • 234107 LICENSING: SSA status was registered only for the user who started ARCHICAD for the first time.
  • 227066 MODEL: 3D styles were not always applied when choosing them via right click from the touchpad.
  • 210355 MODEL: The Guide Line was missing when placing the first item with Routing in MEP.
  • 164862 MODEL: When opening a Detail placed on an Independent Section the Renovation Palette was not active.
  • 228712 MODEL/CRASH: If a Section/Elevation had a deleted element which was still present due to the Manual Update setting of the View, ARCHICAD crashed once a containing Curtain Wall was edited.
  • 230256 MODEL/CRASH: In certain files, regular crashes could be experienced when opening files or when using the Marquee.
  • 228459 MODEL/FREEZE: ARCHICAD could perform slow in case the project was open for a long time and the Cutting Plane was continuously turned on.
  • 228006 MODEL/FREEZE: Generating 3D model could not be finished, ARCHICAD consumed all the memory if connection of model elements contained lots of polygons.
  • 228454 MODEL/REBUILD: If a View in Navigator was rebuilt, it used the currently active corresponding viewpoints scale.
  • 228030 MODEL/USER INTERFACE: Faulty background image textures caused the background image to appear in front of the Model.
  • 215006 MODEL/USER INTERFACE: On a Worksheet with Far from Origin content, display problems could occur while zooming.
  • 230368 USER INTERFACE: For Ultra High Definition (4K) screens, mouse cursor appeared small inside ARCHICAD in Windows 10 with Display Scaling enabled.

New in ArchiCAD 21 Build 4022 Update (Sep 26, 2017)

  • This Update contains various enhancements and fixes since the original release of ARCHICAD 21:
  • 230743 BIMcloud: Automatic email notification about available licenses was ON by default.
  • 230730 BIMcloud: In some cases the BIMcloud/BIM Server Manager was not accessible from ARCHICAD.
  • 229994 CRASH: A large number of point cloud objects caused ARCHICAD to crash in the 3D Window.
  • 229639 DOCUMENT: It was not possible to filter out Doors/Windows and Skylights from the Material List in Component Schedules. The material of these elements appeared as Dotted Lines in the Schedule.
  • 225619 DOCUMENT/LABEL: It was not possible get the percentage of the slope of the roof with the label tool.
  • 230110 EDIT: Door/Window Oversize changes didn't apply on Section/Elevation Views.
  • 228570 EDIT: Drag command did not work on Views in Layout when clicking on Drawing's subelement Fill's hole edge/corner.
  • 229252 EDIT/FAVORITE: Applying a Door/Window Favorite did not apply its Sill Height.
  • 229250 EDIT/FAVORITE: Position and Structural Function category was not saved along with the Favorites.
  • 228038 EDIT/USER INTERFACE: Stair Favorite preview went wrong after selecting the stair symbol parameter set.
  • 229769 FILE/3DS/IMPORT: Prism panels moved away from each other, when the 2D view was not on their Home Story and their originating curves were changed in Rhino.
  • 214001 FILE/BCF/EXPORT: Exporting a BCF file with rotated orientation would result in a wrong camera position in other applications.
  • 230733 FILE/BIMx: Once a password was set for a BIMx publisher set, it could not be removed.
  • 230058 FILE/BIMx/EXPORT: BIMx Hyper-model export could take significantly longer if Categories and Properties were included as the Info Set.
  • 230465 FILE/EXCEL/EXPORT: From Schedules, decimals in superscript could export as wholes into Excel.
  • 230043 FILE/IFC/EXPORT: IfcTypes didn’t work for Pipe Segments and Cable Carrier Segments.
  • 228613 FILE/IFC/EXPORT: In certain cases some Walls were missing from the exported IFC.
  • 226620 FILE/IFC/EXPORT: Some elements could go missing in the exported IFC file if they originated from an IFC file as well.
  • 229954 FILE/IFC/EXPORT/CRASH: ARCHICAD 21 could crash when saving IFC file with wrong Type Mapping.
  • 211307 FILE/IFC/IMPORT: Importing an IFC file could result in an empty ARCHICAD project in certain cases, even though the IFC file could be displayed in other IFC viewer applications.
  • 229463 FILE/IFC/OPEN: It was not possible to open/merge a certain IFC file.
  • 228064 FILE/MODEL/CRASH: Temporary files created from Point Clouds highly decreased the free space of the hard drive, which led ARCHICAD to crash.
  • 228760 FILE/OPEN: Missing Cadimage Add-on data could not be deleted from a project by unticking the "Keep Data" checkbox upon opening the ARHICAD file.
  • 220050 FILE/OPEN/CRASH: ARCHICAD could crash at startup if the last used User Profile contained the IFC Manager palette opened.
  • 229701 GDL: Manual Texture mapping (eg. with TEVE commands) could fail if the Object was mirrored.
  • 228045 GOODIES: Check for Duplicates add-on identified non-duplicated Morph elements as duplicates.
  • 167412 GOODIES: Construction Simulation: If Caption object was used for the movie, it was displayed in wrong scale.
  • 214520 HOTLINK: MOD file saved and imported with ""Add displayed Elements of other Stories"" option turned on worked differently with particular elements.
  • 234107 LICENSING: SSA status was registered only for the user who started ARCHICAD for the first time.
  • 227066 MODEL: 3D styles were not always applied when choosing them via right click from the touchpad.
  • 210355 MODEL: The Guide Line was missing when placing the first item with Routing in MEP.
  • 164862 MODEL: When opening a Detail placed on an Independent Section the Renovation Palette was not active.
  • 228712 MODEL/CRASH: If a Section/Elevation had a deleted element which was still present due to the Manual Update setting of the View, ARCHICAD crashed once a containing Curtain Wall was edited.
  • 230256 MODEL/CRASH: In certain files, regular crashes could be experienced when opening files or when using the Marquee.
  • 228459 MODEL/FREEZE: ARCHICAD could perform slow in case the project was open for a long time and the Cutting Plane was continuously turned on.
  • 228006 MODEL/FREEZE: Generating 3D model could not be finished, ARCHICAD consumed all the memory if connection of model elements contained lots of polygons.
  • 228454 MODEL/REBUILD: If a View in Navigator was rebuilt, it used the currently active corresponding viewpoints scale.
  • 228030 MODEL/USER INTERFACE: Faulty background image textures caused the background image to appear in front of the Model.
  • 215006 MODEL/USER INTERFACE: On a Worksheet with Far from Origin content, display problems could occur while zooming.
  • 230732 TEAMWORK: Teamwork Errors could happen when new elements were created with copying them.
  • 212747 TEAMWORK/BIM Server/BIMcloud: Teamwork pop-up messages containing a request handled via the Teamwork Palette did not disappear, thus blocking from view of the user later messages.
  • 232118 TEAMWORK/EDIT/RAILING: Unsuccessful Teamwork operation error message appeared after deleting railings.
  • 230368 USER INTERFACE: For Ultra High Definition (4K) screens, mouse cursor appeared small inside ARCHICAD in Windows 10 with Display Scaling enabled.

New in ArchiCAD 21 Build 4004 Preview (Aug 30, 2017)

  • This Update contains various enhancements and fixes since the original release of ARCHICAD 21:
  • 230743 BIMcloud: automatic email notification about available licenses was ON by default.
  • 229994 CRASH: A large number of point cloud objects caused ARCHICAD to crash in the 3D Window.
  • 229639 DOCUMENT: It was not possible to filter out Doors/Windows and Skylights from the Material List in Component Schedules. The material of these elements appeared as Dotted Lines in the Schedule.
  • 230110 EDIT: Door/Window Oversize changes didn't apply on Section/Elevation Views.
  • 228570 EDIT: Drag command did not work on Views in Layout when clicking on Drawing's subelement Fill's hole edge/corner.
  • 229252 EDIT/FAVORITE: Applying a Door/Window Favorite did not apply its Sill Height.
  • 229250 EDIT/FAVORITE: Position and Structural Function category was not saved along with the Favorites.
  • 228038 EDIT/USER INTERFACE: Stair Favorite preview went wrong after selecting the stair symbol parameter set.
  • 229769 FILE/3DS/IMPORT: Prism panels moved away from each other, when the 2D view was not on their Home Story and their originating curves were changed in Rhino.
  • 214001 FILE/BCF/EXPORT: Exporting a BCF file with rotated orientation would result in a wrong camera position in other applications.
  • 230733 FILE/BIMx: Once a password was set for a BIMx publisher set, it could not be removed.
  • 230058 FILE/BIMx/EXPORT: BIMx Hyper-model export could take significantly longer if Categories and Properties were included as the Info Set.
  • 230465 FILE/EXCEL/EXPORT: From Schedules, decimals in superscript could export as wholes into Excel.
  • 230043 FILE/IFC/EXPORT: IfcTypes didn’t work for Pipe Segments and Cable Carrier Segments.
  • 228613 FILE/IFC/EXPORT: In certain cases some Walls were missing from the exported IFC.
  • 226620 FILE/IFC/EXPORT: Some elements could go missing in the exported IFC file if they originated from an IFC file as well.
  • 229954 FILE/IFC/EXPORT/CRASH: ARCHICAD 21 could crash when saving IFC file with wrong Type Mapping.
  • 211307 FILE/IFC/IMPORT: Importing an IFC file could result in an empty ARCHICAD project in certain cases, even though the IFC file could be displayed in other IFC viewer applications.
  • 229463 FILE/IFC/OPEN: It was not possible to open/merge a certain IFC file.
  • 228064 FILE/MODEL/CRASH: Temporary files created from Point Clouds highly decreased the free space of the hard drive, which led ARCHICAD to crash.
  • 228760 FILE/OPEN: Missing Cadimage Add-on data could not be deleted from a project by unticking the "Keep Data" checkbox upon opening the ARHICAD file.
  • 220050 FILE/OPEN/CRASH: ARCHICAD could crash at startup if the last used User Profile contained the IFC Manager palette opened.
  • 229701 GDL: Manual Texture mapping (eg. with TEVE commands) could fail if the Object was mirrored.
  • 228045 GOODIES: Check for Duplicates add-on identified non-duplicated Morph elements as duplicates.
  • 167412 GOODIES: Construction Simulation: If Caption object was used for the movie, it was displayed in wrong scale.
  • 214520 HOTLINK: MOD file saved and imported with ""Add displayed Elements of other Stories"" option turned on worked differently with particular elements.
  • 227066 MODEL: 3D styles were not always applied when choosing them via right click from the touchpad.
  • 210355 MODEL: The Guide Line was missing when placing the first item with Routing in MEP.
  • 164862 MODEL: When opening a Detail placed on an Independent Section the Renovation Palette was not active.
  • 228712 MODEL/CRASH: If a Section/Elevation had a deleted element which was still present due to the Manual Update setting of the View, ARCHICAD crashed once a containing Curtain Wall was edited.
  • 230256 MODEL/CRASH: In certain files, regular crashes could be experienced when opening files or when using the Marquee.
  • 228459 MODEL/FREEZE: ARCHICAD could perform slow in case the project was open for a long time and the Cutting Plane was continuously turned on.
  • 228006 MODEL/FREEZE: Generating 3D model could not be finished, ARCHICAD consumed all the memory if connection of model elements contained lots of polygons.
  • 228454 MODEL/REBUILD: If a View in Navigator was rebuilt, it used the currently active corresponding viewpoints scale.
  • 228030 MODEL/USER INTERFACE: Faulty background image textures caused the background image to appear in front of the Model.
  • 215006 MODEL/USER INTERFACE: On a Worksheet with Far from Origin content, display problems could occur while zooming.
  • 230732 TEAMWORK: Teamwork Errors could happen when new elements were created with copying them.
  • 212747 TEAMWORK/BIM Server/BIMcloud: Teamwork pop-up messages containing a request handled via the Teamwork Palette did not disappear, thus blocking from view of the user later messages.
  • 230368 USER INTERFACE: For Ultra High Definition (4K) screens, mouse cursor appeared small inside ARCHICAD in Windows 10 with Display Scaling enabled.

New in ArchiCAD 21 Build 3005 (Aug 23, 2017)

  • New Stair and Railing Tools:
  • Designing stairs is one of the most complex tasks in architecture, since the stair must comply with stringent standards. The countless iterations required to sync design intent with these standards in a specific building has meant tedious, manual work – up until now. The new Stair Tool in ARCHICAD 21 extends architects’ creativity with automatic validation against human ergonomics — on the fly. In other words, ARCHICAD’s algorithms validate thousands of design options in the background and offer architects the most optimal stair designs to choose from within the context of the specific building.
  • With ARCHICAD 21’s next-gen Stair Tool, architects can jump right into the creative process: placing stairs with simple polyline input and choosing from various design options. If a problem can be solved in a variety of ways, the software offers a selection of the best options that fit both the user’s graphical input and the chosen standards. Intuitive graphical methods allow users to easily tweak the stair’s shape and to customize structural and finish components. As for the Railing Tool, one-click input creates an instant associative railing along stairs or other building elements, whose posts and panels can be assigned as patterns, or customized individually.
  • Updated CineRender Engine:
  • CineRender by MAXON offers architects integrated, photo-realistic rendering options in the BIM context. The latest version introduces Light Mapping and Secondary GI methods for more realistic, yet fast rendering.
  • Element Classification System:
  • An ARCHICAD model can be described as a central BIM database that stores all project data and makes it accessible to any project stakeholder. While previous ARCHICAD versions provided a fixed set of Element Classifications, ARCHICAD 21 introduces a flexible way to classify elements supporting any national or company-standard classification system. In addition, classifications are core to intelligent OPEN BIM workflows, providing unprecedented interoperability among disciplines. Classifications can be transferred between projects via XML file format.
  • IFC Model Referencing:
  • Place IFC files as hotlinks into ARCHICAD projects as protected reference content. Model Filtering narrows the inserted IFC reference content by categories, such as Structural or MEP, or by element selection. The inserted IFC model content can be updated easily from the linked source file. If the link is broken, elements of the inserted IFC modules can be edited as regular ARCHICAD elements.
  • Collision Detection:
  • With the evolution of BIM as the de facto workflow, architects increasingly receive consultant information in a BIM format. To help architects fulfill their role as lead coordinator of the model, Collision Detection becomes a standard part of the feature set starting with ARCHICAD 21.
  • In addition to the features highlighted above, ARCHICAD 21 delivers several other performance and functional improvements. For more information about ARCHICAD 21, and to sign up for the online streaming of ARCHICAD 21’s world premiere, please visit www.graphisoft.com/archicad.

New in ArchiCAD 20 Build 6005 Preview (Apr 19, 2017)

  • This Update contains various enhancements and fixes since the original release of ARCHICAD 20:
  • 223773 BIM Server/CRASH: The update installer of BIM Server crashed, if the admin user's name contained non ASCII (e.g.: é) characters
  • 195433 BIMcloud: LDAP usernames containing an apostrophe were not displayed correctly
  • 187469 BIMcloud/BIM Server: If the Manager logged out the user due to inactivity, it did not, after the user entered a password, return the user to the last page visited, instead it presented the home page
  • 165466 BIMcloud/BIM Server: A duplicated project inherited the original project’s access rights
  • 223242 BIMcloud/BIM Server: Delete project/library from Manager could fail in multiselect mode
  • 213768 BIMcloud/FREEZE: The BIMcloud license accounting system did not provide continuity of service if one hardware key providing CALs was removed
  • 199323 BIMcloud/TEAMWORK/HOTLINK: Project with hotlinked Teamwork files opened very slow if a user's license was revoked
  • 220884 CRASH: ARCHICAD 20 crashed after copying shadows in the 3D Window under certain circumstances
  • 220562 CRASH: ARCHICAD crashed when the RoofMaker Tool was started
  • 220872 CRASH: ARCHICAD might no start if its installation harddrive's name contained special character
  • 215369 CRASH: ARCHICAD could crash when repairing a corrupt file
  • 212341 CRASH: In certain cases, clicking "Select Elevation marker on the Home Story and zoom to it" caused ARCHCIAD to crash
  • 220473 DOCUMENT: Change Markers of closed issues were visible on layouts despite the option "Show Markers of latest Revision only" having been turned on in the settings of the current Issue
  • 223324 DOCUMENT: Door width could be listed with wrong values in schedules, if a curtain wall was on the zone boundary
  • 219880 DOCUMENT: In schedules the border settings could not be set correctly in some cases, when 2D Plan Preview fields were listed as well
  • 217614 DOCUMENT: In some cases the Renovation Filters could appear reversed compared to the View
  • 222028 DOCUMENT: It was not possible to modify the ifc property of the selected element by Element Settings dialog when the category had changed
  • 220974 DOCUMENT: Renovation Status randomly changed to Existing
  • 223107 DOCUMENT: The Project Info Given Name Field couldn't be filled in using a JPN ARCHICAD version
  • 220772 DOCUMENT/CRASH: The process of a adjusting dimension chains or objects with dimension chains was not handled safely in 3d Documents
  • 222033 DOCUMENT/CRASH: Importing ARCHICAD 19 Attribute XMLs into ARCHICAD 20 caused it to crash
  • 219623 DOCUMENT/HOTLINK/CRASH: A hotlinked file using Renovation Filters not included in the host file caused a crash
  • 220614 EDIT: In some cases ellipses were rotated in the wrong direction
  • 219721 EXPORT/GOODIES: In ARCHICAD 20 Construction Simulation Add-on created animations showing all construction elements as already built at the begining of the movie
  • 223478 FILE/2DL/EXPORT/CRASH: Sun Shadows led to ARCHICAD crash if they were exported with On a single level option
  • 216547 FILE/C4D/EXPORT: Merging changed geometry from ARCHICAD to Cinema4D didn't work
  • 172547 FILE/DWG: In certain cases, DWG translator got duplicated when Translation Setup was opened
  • 223096 FILE/DWG/EXPORT: DWG export didn't contain dimensions which used negative witness line length value
  • 222137 FILE/DWG/EXPORT: Solid and Percentage Fills didn't export properly to DWF
  • 213874 FILE/IFC/EXPORT: Body colour of openings was exported incorrectly to IFC in some cases
  • 219887 FILE/MODEL/FREEZE: Walls with complex profiles could cause freeze in ARCHICAD during zooming on Floor Plan
  • 223500 FILE/OPEN/CRASH: Crash could happen in case of Opening PLN made in ARCHICAD 13
  • 220975 FILE/OPEN/CRASH: Opening old file caused ARCHICAD to crash due to legacy Find & Select criteria
  • 223335 FILE/RVT/IMPORT: IfcSpaces with curved geometry weren't imported into Revit correctly the Revit Add-in
  • 220525 FILE/SAVE: Rendering texture with Alpha channel gave different results on Windows and Mac OS X
  • 194373 GDL/CRASH: Changing the Subtype of a custom Library Part to Duct Type Fitting caused ARCHICAD to crash
  • 222259 GDL/CRASH: StairMaker could crash with certain fill shapes
  • 224362 HOTLINK: An inconsistent IFC scheme in a hotlink crashed ARCHICAD
  • 220883 HOTLINK: Property values in labels could be lost when the file is Hotlinked into a host file
  • 225623, 225267 HOTLINK: Open and repair did not correct certain Hotlink corruption issues
  • 222939 HOTLINK/CRASH: Multiple Hotlinks using the same name but different paths caused ARCHICAD to crash
  • 219401 HOTLINK/CRASH: A hotlinked file using Renovation Filters not included in the host file caused a crash
  • 206359 MODEL: Cut line of complex wall is not visible in Elevation if node of Elevation line is in outside line of wall
  • 223422 MODEL: Generation of Zones in 3D was slow
  • 221434 MODEL: Level Dimension dimForm could not recognize some symbols
  • 219972, 221933 MODEL: Renovation override contour Line Pen was incorrect in case of demolished openings
  • 218839 MODEL: Texture mapping was distorted after applying Align 3D Texture - Set Origin… command to a curved Wall
  • 217293 MODEL/CRASH: In certain cases roofs could disappear if the Drag Horizontal Ridge command was used to adjust them
  • 215603 MODEL/CRASH: Rebuilding Detail from Source View caused ARCHICAD to crash if Elevation/Section was completely outside the detail boundary but touching the the Detail Marker polygon
  • 223885 TEAMWORK: Communication with server could be slow due to Interactive Scheduler
  • 217503 TEAMWORK: In case of large projects Reserve All could take a significant time to complete
  • 224375 TEAMWORK: In some cases, it was possible that a 3D document on a layout displayed wrong dimension values in Teamwork
  • 193881 TEAMWORK/BIM Server/BIMcloud: It was not possible to keep the local cache of a teamwork project if it was renamed or moved on the server
  • 93860 TEAMWORK/BIMcloud: It was not possible to re-share a project using the same name as the original
  • 221764 TEAMWORK/BIMx/CRASH: Clicking on "Show Elements" button in Teamwork message which came from BIMx caused crash when it was directing to the 3D window
  • 219452 TEAMWORK/DOCUMENT/CRASH: Deletion of unreserved changes in Change Manager caused crash
  • 208758 TEAMWORK/HOTLINK With certain property data in Hotlink Modules ARCHICAD crashed on update
  • 221147 USER INTERFACE: If property had "Option Set" type, Criteria did not register first option
  • 220540 USER INTERFACE: In Element setting, clicking the symbol before the Property name changed the value back to default
  • 223483 USER INTERFACE: When moving a static dimension line the feedback was misleading as if it was only possible to move the dimension in perpendicular direction, while moving itself worked correctly

New in ArchiCAD 20 Build 5025 Preview (Feb 15, 2017)

  • This Update contains various enhancements and fixes since the original release of ARCHICAD 20:
  • 216572 BIM Server: A user database failed to import, if the default location for the Data Folder (BIM Server Manager Configurator setting) had been changed.
  • 214911 BIMcloud: It was not possible for the Administrator to send bulk email to users.
  • 219296 BIMcloud: BTC licenses were limited to the version of the Manager.
  • 202194 BIMcloud: Email configuration checkbox for TLS and SSL were exchanged with N/A.
  • 194711 BIMcloud: It was not possible to display a custom logo on the login page.
  • 173999 BIMcloud: The group name in some cases covered action buttons.
  • 219377 BIMcloud: It was possible for users granted only view permission to modify their own group settings.
  • 201115 BIMcloud: LDAP filter panel select all/deselect all applied indiscriminately to all users and groups, whether or not the panel was being filtered by just users or just groups.
  • 195396 BIMcloud: Projects were not listed correctly on the Manager when ordering was done by Host Server.
  • 218688 BIMcloud: Performance suffered due to a memory allocation routine that slowly served multiple competing threads.
  • 217020 BIMcloud: LDAP synchronization failed when an empty custom field was present.
  • 217924 BIMcloud: The permission summary column available with the detailed permissions method had refresh problems. A new access rule only appeared after the save button had been pressed.
  • 198528 BIMcloud: The warning message about unsaved changes was confusing.
  • 215202 BIMcloud/BIM Server: The Manager did not limit the number of login attempts.
  • 216824 BIMcloud/BIM Server: The Manager default panel of every page was not the settings panel.
  • 219461 BIMcloud/BIM Server: The path of the BlobCache folder could not be reconfigured after the installation.
  • 216868 BIMcloud/BIM Server/Crash: In certain cases, it was possible for the Server to crash when multiple clients were authenticating.
  • 216894 CRASH: Some drawings with cropped views of the model crashed the drawing update.
  • 216563 CRASH: Library picture manipulation over a noisy network led to a crash.
  • 214482 CRASH: A crash resulted from searching BIMComponents.com for an already placed object.
  • 217193 DOCUMENT: 3D previews of complex profile walls were displayed incorrectly in the Schedules if the wall was shorter than one meter and the vertical stretch was enabled for it.
  • 214136 DOCUMENT: 3D window based drawing was not using the line pen override of graphic override combinations in layout.
  • 213519 DOCUMENT: Dimensions were placed incorrectly on curved walls.
  • 184308 DOCUMENT: Display of the wall-column connection on the layout was different from the source view.
  • 216804 DOCUMENT: In certain cases, width of schedule columns could not be resized.
  • 217028 DOCUMENT: Only those complex profiles could be chosen as listing criteria in schedules, which were defined to be applicable for beams.
  • 212736 DOCUMENT: Schedule SUM value disappeared on the layout when it was set to bold and aligned by decimal marker.
  • 214134 DOCUMENT: Schedules were not using the correct graphic override combinations in layout.
  • 215695 DOCUMENT: In certain cases, the layout was not consistent with the source view.
  • 217737 DOCUMENT: Volume calculation of certain objects failed in Interactive Schedules.
  • 216962 DOCUMENT: The migration of a project from ARCHICAD 19 to ARCHICAD 20 caused windows and doors to flip on floor plan.
  • 218853 DOCUMENT: Zone number did not appear in a schedule because criteria was filtered by the element classification, and not by the element type.
  • 212482 EDIT: ARCHICAD crashed when viewing a 2D preview of the curtain wall if the surface assigned to a sub-element of the CW was missing.
  • 217191 EDIT: Graphic override settings did not affect shadows in sections/elevations.
  • 206013 EDIT: Guide Lines kept trimming lines/walls/etc. even when guide lines display was turned off.
  • 216179 EDIT: In certain cases, text size changed after editing it.
  • 195096 EDIT: It was impossible to stretch trapezoid walls with the stretch trapezoid wall pop-up context menu command.
  • 213415 EDIT: A favorite applied to an object in certain cases changed its renovation status.
  • 217128 EDIT: Tracker did not update after using a new user origin.
  • 214549 EDIT: Wall accessory objects didn't refresh after a door/window
  • was moved.
  • 214933 EDIT: The element setting window performance was bad with certain IFC files.
  • 214237 EDIT: The tracker did not update when moving the user origin with Alt+Shift.
  • 211094 EDIT: Combined usage of pan and zoom gave unexpected results.
  • 218601 EDIT/FREEZE: Performance issues resulted if the surface painter, surface settings or photorendering settings were open.
  • 219695 FILE/3DS/EXPORT : Japanese characters in folder paths caused 3dm exports to fail.
  • 213639 FILE/3DM/IMPORT/CRASH: ARCHICAD crashed while importing certain 3DM files.
  • 219964 FILE/BIMX/EXPORT: ARCHICAD skipped the global Illumination calculation if the username contained a double byte character.
  • 213255 FILE/BIMx/EXPORT: The BIMx wizard always published IES info.
  • 216386 FILE/DOCUMENT: The checkbox "Include Scale in Autotexting and Indexes” in the drawing's settings affected the drawing title.
  • 215089 FILE/DOCUMENT: Window height dimensions didn't change automatically if the number of the dimension decimals was changed.
  • 217105 FILE/DWF/EXPORT: In some cases, grid elements were not exported to DWF.
  • 216743 FILE/DWG/EXPORT: Section story level markers didn't export into DWG/DWF from Worksheets.
  • 214802 FILE/DWG/EXPORT/CRASH: Certain linetypes (Regenwater, Afvalwater, FEC 110) crashed ARCHICAD when layouts were published to DWG.
  • 213911 FILE/EDIT: Dimensions placed on to 3D documents in most cases couldn't be moved.
  • 213798 FILE/EXCEL/IMPORT: ARCHICAD couldn't import properties from Excel files containing only a single column.
  • 214393 FILE/IFC: The IFC scheme in German templates wasn’t correct.
  • 214791 FILE/IFC/CRASH: A crash resulted, if an IFC parameter referenced a missing library part.
  • 214661 FILE/IFC/EXPORT: A rotated survey point corrupted the IFC Solibri model view.
  • 213864 FILE/IFC/EXPORT/CRASH: ARCHICAD crashed during IFC4 export with certain files.
  • 210453 FILE/IMPORT: The default outline type of imported steel profiles was incorrect in the NED language version.
  • 193355 FILE/IMPORT: Surfaces localized to a non-English name upon import to the surface painter took on their original English name.
  • 218607 FILE/MODEL/FREEZE: The Etancheite fill (used in the FRA template) caused performance issues.
  • 219778 FILE/MODEL/FREEZE: The Izolace-hydroizolace fill (used in the CZE template) caused performance issues.
  • 217817 FILE/OPEN/CRASH: Text color data was not handled correctly and crashed ARCHICAD after presenting an "Internal error was found" message.
  • 214385 FILE/OPEN/FREEZE: Vectorial fills containing zero length lines caused ARCHICAD to freeze.
  • 213835 FILE/PLN: Migration process of section/elevations was poorly optimized. The result was that large projects took unnecessarily too long to migrate.
  • 213881 FILE/PLN/CRASH: ARCHICAD crashed from a degenerated plane roof.
  • 217984 FILE/PMK: Occasionally publication to PMKs included elements that were not in their source views.
  • 219827 FILE/SAVE: File size grew drastically with detail/worksheet rebuilds.
  • 216748 FILE/SAVE/FREEZE: ARCHICAD could freeze when saving back to ARCHICAD 19 files containing meshes due to the slow generating of certain cut fills.
  • 215733 FILE/USER INTERFACE: Checkboxes couldn't be activated by clicking on them, when their text was displayed in multiple lines.
  • 214292 FILE/USER INTERFACE: The icons on the set up list schemes/select viewpoint weren't displayed.
  • 213878 FILE/XLS/IMPORT: Invalid quantity values were imported when using merge uniform items option.
  • 219049 GDL: After creating a new array type parameter for an object in the GDL editor dialog, all available parameters with optional values were locked.
  • 216740 GDL: Hidden scripts were visible.
  • 212270 GDL: It was impossible in ARCHICAD to download content from BIMcomponents.com if a proxy server was used.
  • 214302 GDL: Library objects containing ellipsoids had incorrectly rendered previews in the object’s settings dialog and on floor plans.
  • 218292 GDL: Certain values in a list were falsely considered duplicates.
  • 216771 GDL/CRASH: A detailed/simple tree corrupted memory to the extent that ARCHICAD crashed.
  • 216066 LABEL/IFC: The Name and Value of IFC parameters were switched in the categories and properties label.
  • 215625 MODEL: "Show on Renovation Filter" couldn't be added as a graphic override criteria.
  • 211605 MODEL: Grid elements could have been duplicated after editing story settings.
  • 218907 MODEL: Projection settings reverted back to the default settings after creating a PhotoRendering.
  • 217362 MODEL: Rendering with default settings was slower in ARCHICAD 20 than in ARCHICAD 19.
  • 218839 MODEL: Texture mapping was distorted after applying Align 3D Texture - Set Origin command to a curved Wall.
  • 216867 MODEL/DOCUMENTATION: Layout and source view could be different in particular cases.
  • 214462 MODEL/FREEZE: In certain cases, grid elements caused slowness in 2D zoom/pan.
  • 212777 MODEL/FREEZE: Using 2D Pan function caused freeze in particular cases.
  • 217076 TEAMWORK: A reason was addressed for a false warning of an error occurring during the last Teamwork operation.
  • 216264 TEAMWORK: Defective elements in local cache prevented send.
  • 217037 TEAMWORK: In some cases, using ‚"Drag a Copy" resulted in damaged IFC data which could cause send & receive errors.
  • 215602 TEAMWORK: Modifications of dimension elements with missing links resulted in error message during send & receive.
  • 214554 TEAMWORK/BIM Server/BIMcloud: Incomplete backup files were not removed from file system if backup operation failed.
  • 204281 TEAMWORK/BIM Server/BIMcloud: Messages could not be sent and users were not visible due to mailboxes.db corruption on the server.
  • 219811 TEAMWORK/DOCUMENT: Parts of the dimension could disappear in Teamwork, if some of their points were moved and the changes were sent and received.
  • 219757 TEAMWORK/EDIT/USER INTERFACE: The favorites palette, favorites pop-ups from toolbox and info box performed sluggishly.
  • 215068 TEAMWORK/USER INTERFACE: The ESC key did not work if the Teamwork status appeared in a palette and other palettes were not docked.
  • 217361 USER INTERFACE: New SSA Site link appeared in the options menu for the SPA localized version.
  • 215426 USER INTERFACE: The focus didn't change to floor plan if a favorite was selected by double click from the favorites palette.
  • 214625 USER INTERFACE: Cel Renderer parameters were missing in PhotoRendering Settings.
  • 215960 USER INTERFACE: Couldn't save the witness line length into a favorite with the redefine command.
  • 214153 USER INTERFACE: Favorite export ignored settings made in categories and properties.
  • 217458 USER INTERFACE: Hidden elements showed on floor plan if the floor plan tab was chosen right after displaying the 3D model.
  • 143514 VIEW: Shadows of edges shorter than 1cm in 3D could be noisy in OpenGL.

New in ArchiCAD 20 Build 5011 (Jan 26, 2017)

  • This Update contains various enhancements and fixes since the original release of ARCHICAD 20.
  • 216572 BIM Server: A user database failed to import, if the default location for the Data Folder (BIM Server Manager Configurator setting) had been changed.
  • 214911 BIMcloud: It was not possible for the Administrator to send bulk email to users.
  • 219296 BIMcloud: BTC licenses were limited to the version of the Manager.
  • 202194 BIMcloud: Email configuration checkbox for TLS and SSL were exchanged with N/A.
  • 194711 BIMcloud: It was not possible to display a custom logo on the login page.
  • 173999 BIMcloud: The group name in some cases covered action buttons.
  • 219377 BIMcloud: It was possible for users granted only view permission to modify their own group settings.
  • 201115 BIMcloud: LDAP filter panel select all/deselect all applied indiscriminately to all users and groups, whether or not the panel was being filtered by just users or just groups.
  • 195396 BIMcloud: Projects were not listed correctly on the Manager when ordering was done by Host Server.
  • 218688 BIMcloud: Performance suffered due to a memory allocation routine that slowly served multiple competing threads.
  • 217020 BIMcloud: LDAP synchronization failed when an empty custom field was present.
  • 217924 BIMcloud: The permission summary column available with the detailed permissions method had refresh problems. A new access rule only appeared after the save button had been pressed.
  • 198528 BIMcloud: The warning message about unsaved changes was confusing.
  • 215202 BIMcloud/BIM Server: The Manager did not limit the number of login attempts.
  • 216824 BIMcloud/BIM Server: The Manager default panel of every page was not the settings panel.
  • 219461 BIMcloud/BIM Server: The path of the BlobCache folder could not be reconfigured after the installation.
  • 216868 BIMcloud/BIM Server/Crash: In certain cases, it was possible for the Server to crash when multiple clients were authenticating.
  • 216894 CRASH: ARCHICAD Some drawings with cropped views of the model crashed the drawing update.
  • 216563 CRASH: Library picture manipulation over a noisy network led to a crash.
  • 214482 CRASH: A crash resulted from searching BIMComponents.com for an already placed object.
  • 217193 DOCUMENT: 3D previews of complex profile walls were displayed incorrectly in the Schedules if the wall was shorter than one meter and the vertical stretch was enabled for it.
  • 214136 DOCUMENT: 3D window based drawing was not using the line pen override of graphic override combinations in layout.
  • 213519 DOCUMENT: Dimensions were placed incorrectly on curved walls.
  • 184308 DOCUMENT: Display of the wall-column connection on the layout was different from the source view.
  • 216804 DOCUMENT: In certain cases, width of schedule columns could not be resized.
  • 217028 DOCUMENT: Only those complex profiles could be chosen as listing criteria in schedules, which were defined to be applicable for beams.
  • 212736 DOCUMENT: Schedule SUM value disappeared on the layout when it was set to bold and aligned by decimal marker.
  • 214134 DOCUMENT: Schedules were not using the correct graphic override combinations in layout.
  • 215695 DOCUMENT: In certain cases, the layout was not consistent with the source view.
  • 217737 DOCUMENT: Volume calculation of certain objects failed in Interactive Schedules.
  • 216962 DOCUMENT: The migration of a project from ARCHICAD 19 to ARCHICAD 20 caused windows and doors to flip on floor plan.
  • 218853 DOCUMENT: Zone number did not appear in a schedule because criteria was filtered by the element classification, and not by the element type.
  • 212482 EDIT: ARCHICAD crashed when viewing a 2D preview of the curtain wall if the surface assigned to a sub-element of the CW was missing.
  • 217191 EDIT: Graphic override settings did not affect shadows in sections/elevations.
  • 206013 EDIT: Guide Lines kept trimming lines/walls/etc. even when guide lines display was turned off.
  • 216179 EDIT: In certain cases, text size changed after editing it.
  • 195096 EDIT: It was impossible to stretch trapezoid walls with the stretch trapezoid wall pop-up context menu command.
  • 213415 EDIT: A favorite applied to an object in certain cases changed its renovation status.
  • 217128 EDIT: Tracker did not update after using a new user origin.
  • 214549 EDIT: Wall accessory objects didn't refresh after a door/window
  • was moved.
  • 214933 EDIT: The element setting window performance was bad with certain IFC files.
  • 214237 EDIT: The tracker did not update when moving the user origin with Alt+Shift.
  • 211094 EDIT: Combined usage of pan and zoom gave unexpected results.
  • 218601 EDIT/FREEZE: Performance issues resulted if the surface painter, surface settings or photorendering settings were open.
  • 219695 FILE/3DS/EXPORT : Japanese characters in folder paths caused 3dm exports to fail.
  • 213639 FILE/3DM/IMPORT/CRASH: ARCHICAD crashed while importing certain 3DM files.
  • 219964 FILE/BIMX/EXPORT: ARCHICAD skipped the global Illumination calculation if the username contained a double byte character.
  • 213255 FILE/BIMx/EXPORT: The BIMx wizard always published IES info.
  • 216386 FILE/DOCUMENT: The checkbox "Include Scale in Autotexting and Indexes” in the drawing's settings affected the drawing title.
  • 215089 FILE/DOCUMENT: Window height dimensions didn't change automatically if the number of the dimension decimals was changed.
  • 217105 FILE/DWF/EXPORT: In some cases, grid elements were not exported to DWF.
  • 216743 FILE/DWG/EXPORT: Section story level markers didn't export into DWG/DWF from Worksheets.
  • 214802 FILE/DWG/EXPORT/CRASH: Certain linetypes (Regenwater, Afvalwater, FEC 110) crashed ARCHICAD when layouts were published to DWG.
  • 213911 FILE/EDIT: Dimensions placed on to 3D documents in most cases couldn't be moved.
  • 213798 FILE/EXCEL/IMPORT: ARCHICAD couldn't import properties from Excel files containing only a single column.
  • 214393 FILE/IFC: The IFC scheme in German templates wasn’t correct.
  • 214791 FILE/IFC/CRASH: A crash resulted, if an IFC parameter referenced a missing library part.
  • 214661 FILE/IFC/EXPORT: A rotated survey point corrupted the IFC Solibri model view.
  • 213864 FILE/IFC/EXPORT/CRASH: ARCHICAD crashed during IFC4 export with certain files.
  • 210453 FILE/IMPORT: The default outline type of imported steel profiles was incorrect in the NED language version.
  • 193355 FILE/IMPORT: Surfaces localized to a non-English name upon import to the surface painter took on their original English name.
  • 218607 FILE/MODEL/FREEZE: The Etancheite fill (used in the FRA template) caused performance issues.
  • 219778 FILE/MODEL/FREEZE: The Izolace-hydroizolace fill (used in the CZE template) caused performance issues.
  • 217817 FILE/OPEN/CRASH: Text color data was not handled correctly and crashed ARCHICAD after presenting an "Internal error was found" message.
  • 214385 FILE/OPEN/FREEZE: Vectorial fills containing zero length lines caused ARCHICAD to freeze.
  • 213835 FILE/PLN: Migration process of section/elevations was poorly optimized. The result was that large projects took unnecessarily too long to migrate.
  • 213881 FILE/PLN/CRASH: ARCHICAD crashed from a degenerated plane roof.
  • 217984 FILE/PMK: Occasionally publication to PMKs included elements that were not in their source views.
  • 219827 FILE/SAVE: File size grew drastically with detail/worksheet rebuilds.
  • 216748 FILE/SAVE/FREEZE: ARCHICAD could freeze when saving back to ARCHICAD 19 files containing meshes due to the slow generating of certain cut fills.
  • 215733 FILE/USER INTERFACE: Checkboxes couldn't be activated by clicking on them, when their text was displayed in multiple lines.
  • 214292 FILE/USER INTERFACE: The icons on the set up list schemes/select viewpoint weren't displayed.
  • 213878 FILE/XLS/IMPORT: Invalid quantity values were imported when using merge uniform items option.
  • 219049 GDL: After creating a new array type parameter for an object in the GDL editor dialog, all available parameters with optional values were locked.
  • 216740 GDL: Hidden scripts were visible.
  • 212270 GDL: It was impossible in ARCHICAD to download content from BIMcomponents.com if a proxy server was used.
  • 214302 GDL: Library objects containing ellipsoids had incorrectly rendered previews in the object’s settings dialog and on floor plans.
  • 218292 GDL: Certain values in a list were falsely considered duplicates.
  • 216771 GDL/CRASH: A detailed/simple tree corrupted memory to the extent that ARCHICAD crashed.
  • 216066 LABEL/IFC: The Name and Value of IFC parameters were switched in the categories and properties label.
  • 215625 MODEL: "Show on Renovation Filter" couldn't be added as a graphic override criteria.
  • 211605 MODEL: Grid elements could have been duplicated after editing story settings.
  • 218907 MODEL: Projection settings reverted back to the default settings after creating a PhotoRendering.
  • 217362 MODEL: Rendering with default settings was slower in ARCHICAD 20 than in ARCHICAD 19.
  • 218839 MODEL: Texture mapping was distorted after applying Align 3D Texture - Set Origin command to a curved Wall.
  • 216867 MODEL/DOCUMENTATION: Layout and source view could be different in particular cases.
  • 214462 MODEL/FREEZE: In certain cases, grid elements caused slowness in 2D zoom/pan.
  • 212777 MODEL/FREEZE: Using 2D Pan function caused freeze in particular cases.
  • 217076 TEAMWORK: A reason was addressed for a false warning of an error occurring during the last Teamwork operation.
  • 216264 TEAMWORK: Defective elements in local cache prevented send.
  • 217037 TEAMWORK: In some cases, using ‚"Drag a Copy" resulted in damaged IFC data which could cause send & receive errors.
  • 215602 TEAMWORK: Modifications of dimension elements with missing links resulted in error message during send & receive.
  • 214554 TEAMWORK/BIM Server/BIMcloud: Incomplete backup files were not removed from file system if backup operation failed.
  • 204281 TEAMWORK/BIM Server/BIMcloud: Messages could not be sent and users were not visible due to mailboxes.db corruption on the server.
  • 219811 TEAMWORK/DOCUMENT: Parts of the dimension could disappear in Teamwork, if some of their points were moved and the changes were sent and received.
  • 219757 TEAMWORK/EDIT/USER INTERFACE: The favorites palette, favorites pop-ups from toolbox and info box performed sluggishly.
  • 215068 TEAMWORK/USER INTERFACE: The ESC key did not work if the Teamwork status appeared in a palette and other palettes were not docked.
  • 217361 USER INTERFACE: New SSA Site link appeared in the options menu for the SPA localized version.
  • 215426 USER INTERFACE: The focus didn't change to floor plan if a favorite was selected by double click from the favorites palette.
  • 214625 USER INTERFACE: Cel Renderer parameters were missing in PhotoRendering Settings.
  • 215960 USER INTERFACE: Couldn't save the witness line length into a favorite with the redefine command.
  • 214153 USER INTERFACE: Favorite export ignored settings made in categories and properties.
  • 217458 USER INTERFACE: Hidden elements showed on floor plan if the floor plan tab was chosen right after displaying the 3D model.
  • 143514 VIEW: Shadows of edges shorter than 1cm in 3D could be noisy in OpenGL.

New in ArchiCAD 20 Build 4020 (Nov 28, 2016)

  • Issues solved in ARCHICAD 20 Update 4020:
  • This Update contains various enhancements and fixes since the original release of ARCHICAD 20.
  • 216288 BIM Server/BIMcloud/DOCUMENT: Deleted Interior Elevation segments could re-appear in the Project Map after sharing the PLN file as a Teamwork project.
  • 214692 HOTLINK: Elements in Nested Hotlinks could become ungrouped and editable after refreshing Hotlinks in the Host Teamwork file.
  • 213718 MODEL: When creating a 3D element with a numeric input in the Tracker's Z coordinate field, the resulting height could differ from the input value.
  • 216009 TEAMWORK/FILE/OPEN: In some cases when storing external drawings on a MAC fileserver, ARCHICAD could continuously ask for authentication information or show the drawings as Missing in the Drawing Manager.

New in ArchiCAD 19 Build 5005 Update (Feb 23, 2016)

  • This Update contains various enhancements and fixes since the original release of ARCHICAD 19:
  • 197402 BIMx: 3D model did not appear in BIMx hyper model, if double byte characters were part of the login name.
  • 196342 BIMx: Limit navigation to gallery item didn't work in desktop version.
  • 196807 CRASH: ARCHICAD could crash because of Morph elements placed into zones.
  • 199056 CRASH: If Navigator Preview was open during a point cloud import to section, ARCHICAD 19 crashed.
  • 198395 DOCUMENT/CRASH: ARCHICAD could crash with certain Interactive Schedule criteria.
  • 191699 DOCUMENT/EDIT: The 'Show Grid Elements' option in the Settings Dialog of Interior Elevations was not stored after closing the dialog.
  • 199166 DOCUMENT/FREEZE: Curtain Wall panel schedules could freeze with certain criteria in the Scheme Setup.
  • 195044 DOCUMENT/MODEL: It was not possible to place Snap Guides to elements of a Traced&Referenced Drawing.
  • 198921 DOCUMENT: Area by story for Morph elements was not listed properly.
  • 199581 DOCUMENT: Certain 2-byte characters (e.g. the Japanese Character 合) couldn't be entered into an Interactive Schedule Field.
  • 197426 DOCUMENT: Certain Labels displayed 'Undefined' on Layouts while they displayed the necessary information correctly on View Map/Project Map.
  • 198290 DOCUMENT: If the 3D window was wider than 2048 pixel, the texture background offset was different between render and 3D view.
  • 198412 DOCUMENT: Interior Elevation drawings were updated every time you opened the layout they were on, even though nothing changed.
  • 197723 DOCUMENT: The length of Dimension witness lines with certain settings changed when the dimension was moved.
  • 197524 EDIT/CRASH: ARCHICAD crashed because of Roof Thickness and Wall Thickness parameters in scheme setup.
  • 198396 EDIT/CRASH: Editing reference line of polygonal wall with marquee caused a crash.
  • 199861 EDIT/CRASH: In certain cases ARCHICAD crashed when you tried to drag-a-copy of multiple selected elements in a Section/Elevation.
  • 198253 EDIT: "Merge walls" function did not work.
  • 197483 EDIT: ARCHICAD 19 sometimes crashed after editing a text or a label.
  • 200890 EDIT: External drawings and hotlinks - which were stored on a mounted drive - were missing from the project and could not be relinked or updated if at least one user modified the project on OS X 10.11 El Capitan.
  • 198073 EDIT: It wasn't possible to select the Curtain Wall in the Section/Elevation view if the Floor Plan Display was set to Projected.
  • 195863 EDIT: Size of the columns placed in Grid System could not be changed.
  • 196927 EDIT: Switching from Marquee in 3D view to floorplan was slow if labels were in selection.
  • 196919 EDIT: Switching from Marquee in 3D view to floorplan was slow in case grid elements were in selection.
  • 198268 EDIT: The offset of Text frame appeared incorrectly after mirroring it.
  • 194045 EDIT: Trace & Reference color could turn grey if the Reference Intensity was changed.
  • 192460 FILE/DWG/EXPORT: Cut-Building Material Fills or Fills with transparent Background on a Worksheet, placed on a Layout were not exported.
  • 196436 FILE/DWG/EXPORT/FREEZE: ArchiCAD froze during DWG export if certain East-Asian Fonts were installed improperly.
  • 196856 FILE/E57/IMPORT: Certain E57 Point Cloud Files could fail to import.
  • 200762 FILE/IFC: the zone number attribute mapped as IFC name attribute could show invalid value in schedules.
  • 195569 FILE/SAVE: When ARCHICAD was closed the Save dialog information was misleading for rendered images.
  • 198475 FREEZE: A special symbol Fill could cause performance problems.
  • 197394 FREEZE: ARCHICAD could freeze when the elements were placed far from the origin and the Snap Guides were turned on.
  • 198083 FREEZE: ARCHICAD 19 needed a lot of time to zoom in to certain fills.
  • 198399 FREEZE: ARCHICAD could freeze if a Fly-through was created with too many frames.
  • 198737 FREEZE: In a special project the Copy/Paste was slower in ARCHICAD 19 than in ARCHICAD 16.
  • 196223 GDL: Saving Door panels from the floor plan resulted in a wrong saved geometry.
  • 199057 GDL: The SYMB_MIRRORED gdl command did not work in case of Curtain Wall panels.
  • 198162 HOTLINK: In some cases when the Hotlink has been removed from the project some of the Dimensions of the Hotlink were not deleted.
  • 198293 INSTALLER: The update installer was able to run again on an already updated ArchiCAD.
  • 201123 MODEL/FREEZE: ARCHICAD could freeze if double byte characters were typed into the Story Settings.
  • 196969 MODEL: 2D tree did not rotate automatically to continuously face the camera during fly-through.
  • 197021 MODEL: ARCHICAD 19 crashed when a zone was placed with Inner Edge geometry method.
  • 198853 MODEL: Curtain wall frame could disappear if it was moved or stretched in Edit mode.
  • 196700 MODEL: Insert a new camera after the selected one function did not work correctly. The new camera was always placed to the end of the path.
  • 200230 MODEL: Look to Perpendicular of Clicked Surface used in 3D Window could occasionally cause the model to disappear.
  • 197476 MODEL: Pan/Zoom could be slow if a fill’s Vectorial Hatching contained a lot of lines.
  • 192060/199034 MODEL: Rotation of columns was wrong when certain files were exported to IFC (they were incorrectly rotated with -180 degrees).
  • 199311 MODEL: Sun shadows were incorrect in case of Sketchup imported objects.
  • 199098 MODEL: Wall Ends disappeared if the 'Hide on Floor plan' MVO setting of Windows was turned on.
  • 195082 TEAMWORK: A click on the bounding box of an unreserved I/E marker caused ARCHICAD to crash.
  • 198722 TEAMWORK: Receive performance was optimized in the area of the drawing manager and project navigator data.
  • 199250 TEAMWORK: Fly-Through could not be saved in Teamwork projects.
  • 196747 TEAMWORK: In rare cases, the ‘Communicating with server’ dialog got stuck during the project opening process.
  • 188214 TEAMWORK: Receive stability was improved in cases that involved section data.
  • 196215 TEAMWORK: Sun Study could not be saved in Teamwork projects.
  • 195904 TEAMWORK/BIMcloud: Support Package could not be created by BIMcloud Team Client.
  • 196811 TEAMWORK/BIMcloud: The 'Relink Home Story' function was missing from BIMcloud Team Client.
  • 198717 TEAMWORK/BIMcloud: Scroll bar for search results in BIMcloud Manager was missing.
  • 198606 TEAMWORK/BIMcloud: Search field in Manager Browser interface incorrectly handled click events during Japanese character entry.
  • 199038 TEAMWORK/BIMcloud: Version 18 BIMcloud Server licenses were not released after upgrading BIMcloud to version 19.
  • 202152 TEAMWORK/BIMcloud/ LDAP Connection: Long queries failed with Error code 7.
  • 201116 TEAMWORK/BIMcloud/ LDAP Connection: If preview set large, scrolling returned empty screen.
  • 193858 TEAMWORK/BIM Server/BIMcloud: In case of specific SMTP settings, the Manager could not send email to the users.
  • 201786 TEAMWORK/BIM Server/BIMcloud: Send email function didn’t work because system could not connect to SMTP.
  • 196715 TEAMWORK/BIM Server/BIMcloud: In some cases, the Data folder path could not be modified with the Manager Configurator.
  • 202491 TEAMWORK/BIM Server/BIMcloud: Modified garbage collection arguments lost at update installation.
  • 198156 TEAMWORK/BIM Server/BIMcloud: Under certain circumstances, the Projects folder path could not be modified with the Configurator and an error message came up.
  • 196797 TEAMWORK/BIM Server/BIMcloud: the server could crash on OS X when it reached the limit of the available Thread Local Storage Slots.
  • 199688 TEAMWORK/BIM Server/BIMcloud: the server stopped serving requests on OS X when the combined number of open files/network connections reached 1024.
  • 197089 TEAMWORK/BIM Server/BIMcloud: Under certain circumstances if attributes were modified, an error could happen during Send & Receive.
  • 199565 TEAMWORK/CRASH: Under certain circumstances ARCHICAD could crash during Send & Receive.
  • 199964 TEAMWORK/DOCUMENT: Custom position Dimension texts could reset to default position in TeamWork project when the containing section was opened.
  • 197500 TEAMWORK/EDIT: Elements on locked layers were not skipped from copy/paste.
  • 199842 USER INTERFACE: A dialog used during editing was missing from the Truss Maker.
  • 198097 USER INTERFACE: Build number in "License Info" and on "about ARCHICAD" splash screen could be different.
  • 195705 USER INTERFACE: Changing the ID of a layout subset was not possible under Properties in the Navigator.
  • 193382 USER INTERFACE: EDU/TRIAL serial number’s first part did not appear on the activation dialog if the serial number was copy-pasted on Macintosh.
  • 193385 USER INTERFACE: In certain cases, Dialog Boxes were displayed in the wrong order on OS X 10.11 El Capitan.
  • 195358 USER INTERFACE: The composite settings panel was optimized.
  • 198734 USER INTERFACE: The Printer Dialogue Settings displayed Resolution options that could not be used.

New in ArchiCAD 19 Build 4014 (Dec 11, 2015)

  • This Update provides an important fix to an error of ARCHICAD 19 Solo Update build 4003: "199288: Snapping fails and causes wrong feedback and placement of elements in certain circumstances".

New in ArchiCAD 19 Build 4013 (Nov 30, 2015)

  • This Update fixes the following bug in ARCHICAD 19 build 4011:
  • 199288 EDIT: Snapping fails and causes wrong feedback and placement of elements in certain circumstances.

New in ArchiCAD 19 Build 4011 (Nov 25, 2015)

  • Update package Build 4011 contains ARCHICAD and BIM Server build 4006 and BIM Server Manager build 4011. This means that:
  • The package build number (registered in the ProductVersion.xml) is 4011
  • BIM Server build number is 4006
  • BIM Server Manager is 4011
  • ARCHICAD.exe build number is 4006.
  • Note that the “About ARCHICAD” splash screen will correctly display build 4011. Due to an error, License Information dialog will show build 4006.
  • The Update applies to ARCHICAD, BIM Server and all other components: BIMx, MEP Modeler and all GRAPHISOFT-distributed Add-Ons and Goodies. It applies to all (Commercial, Educational and Trial) license types.

New in ArchiCAD 19 Build 3003 (Jul 14, 2015)

  • ARCHICAD 19 is now faster than ever! No more waiting for views to load. GRAPHISOFT has extended its robust 64-bit and multi-processing technologies with background processing – an industry first for BIM. So ARCHICAD now offers lightning-fast response times and this turbo-charged update to ARCHICAD makes it the undisputed speed leader in the BIM business.
  • Performance:
  • ARCHICAD 19 offers industry-first, real-time BIM collaboration regardless of the size, location or distribution of the collaborating team.
  • Background Processing:
  • ARCHICAD 19 takes advantage of unused computer capacity by anticipating what you might do next – and preparing those actions in the background.
  • Architecture:
  • ARCHICAD 19 makes the most time- consuming and often boring part of an architect’s work much more fun.
  • Intuitiveness:
  • ARCHICAD 19 provides major work environment improvements for both Mac and Windows users.
  • OPEN BIM:
  • Improved IFC-based collaboration and collision detection (using the MEP Modeler add-on) improves OPEN BIM collaboration between architects and engineers.

New in ArchiCAD 18 Update 6000 Update (Jul 11, 2015)

  • applies to ARCHICAD, BIM Server and all other components: BIMx, MEP Modeler and all GRAPHISOFT-distributed Add-Ons and Goodies.
  • applies to all (Commercial, Educational and Trial) license types.

New in ArchiCAD 18 Update 4020 Update (Nov 1, 2014)

  • The Update:
  • includes important improvements since the original release of ArchiCAD 18 (Build 3006).
  • applies to ArchiCAD, BIM Server and all other components: BIMx, MEP Modeler and all GRAPHISOFT-distributed Add-Ons and Goodies.
  • applies to all (Commercial, Educational and Trial) license types.

New in ArchiCAD 18 Build 3006 (Nov 1, 2014)

  • ArchiCAD 18 offers a streamlined workflow solution, keeping architects in the state of the creative design flow with as little disruption as possible.
  • World Class Rendering:
  • The integration of CineRender, MAXON’s world-class CINEMA 4D rendering engine into ArchiCAD 18, brings high quality, photo-realistic rendering images closer to a much wider range of designers.
  • Revision Management:
  • ArchiCAD 18 provides new, fully integrated Revision Management workflows and streamlined PDF support to greatly improve design data exchange and change management with clients, consultants and the authorities.
  • OPEN BIM:
  • ArchiCAD 18 continues to support OPEN BIM workflows and introduces the first architectural BIM application with full BIM Collaboration Format support.
  • BIMcloud Integration:
  • ArchiCAD 18 offers industry-first, real-time BIM collaboration regardless of the size, location or distribution of the collaborating team.
  • Workflow Enhancements:
  • ArchiCAD 18 unveils substantial enhancements to its existing workflows proving that listening to customers is of primary importance when assigning development resources at GRAPHISOFT.

New in ArchiCAD 17.0 Build 6004 Hotfix 7 (May 7, 2014)

  • Issues solved since the release of Hotfix Build 5014:
  • 166049 BIMx: BIMx export from models with high resolution textures gave incorrect result in BIMx mobile
  • 166982 BIMx: BIMx for ArchiCAD 17 could not save old BIMx files
  • 168005 BIMx: Section and Elevation Hyperlinks of BIMx Hyper-model could disappear if the S/E Vertical Range was limited
  • 167679 CRASH: ArchiCAD could crash when importing IFC files containing Building Element Parts with missing geometry.
  • 170841 CRASH: ArchiCAD could crash when the project contained hotlink cache without source reference
  • 160032 CRASH: Opening a layout while working in Profile Editor could result crash in certain situations
  • 118019 DATA LOSS: Grid System with the Show on Story setting on Custom and invisible on a particular story could be displaced without any notice
  • 170194 DOCUMENT: Different building materials were counted as uniform items by the schedule in case their attribute ID numbers matched
  • 166889 DOCUMENT: Interactive Schedule/Component: The list summarized the value of the "Composite Skin Thickness" if the Show uniform items as single entry parameter was turned on
  • 164979 DOCUMENT: Interior Elevation stability improvements were made
  • 169629 DOCUMENT: Linked section markers disappeared from layout if the marker setting is not "Show on all stories"
  • 167825 DOCUMENT: Llist schemes could not be saved into their default embedded folder
  • 168836 DOCUMENT: ODBC tables didn't contain the Renovation Status attribute
  • 166145 DOCUMENT: Part of the saved .png, .jpg images was black if the pictures were portrait orientated
  • 167913 DOCUMENT: Particular dimensions disappeared after changing section's/elevation's status from Auto-rebuild Model to Drawing
  • 168307 DOCUMENT: Placing Level Dimensions with Gravity to Slab didn't work if the Slab had To Be Demolished or New Renovation Status.
  • 166669 DOCUMENT: Profile beam top/bottom values are no longer reported differently between versions 16 and 17
  • 168228 DOCUMENT: Publishing single file PDF with footer turned on additional blank pages were created
  • 171585 DOCUMENT: Upon opening an AC16 file, level dimensions possibly moved away if the original polygon points were altered since the original creation
  • 169606 DOCUMENT: Wall outer arc dimension value of bent wall was incorrect
  • 163570 DOCUMENT/CRASH: ArchiCAD could crash using Flachenbereichnung listing
  • 127020, 157530 DOCUMENT/CRASH: ArchiCAD could crash when multiple schedule windows were open in maximized mode and a palette was resized.
  • 168035 DOCUMENT/CRASH: Extremely short polylines with arrowhead could cause crash when the layout was updated
  • 169175 EDIT: Guide lines appeared only in the Origin, not at the starting point of the elements
  • 169836 EDIT: 2d floorplan intersection of a curved wall and a straight wall, with a column at the meeting point was rendered wrong
  • 169603 EDIT: After splitting a zone, two zone stamps were erroneously placed in the center of the split on top of each other
  • 168389 EDIT: Applying favorite in wall settings dialog no longer changes renovation status from "new" to "existing"
  • 169694 EDIT: Beams, objects, slabs, roofs, meshes, shells and morph elements did not retain home story specific settings in spite of the home story checkbox checked in favorite preferences
  • 161717 EDIT: Bubble line (often used for revision bubbles) turned inside out when drawing a full closed bubble
  • 167759 EDIT: Changes in the Object Settings didn't update the dialogue for Custom Panels
  • 161987 EDIT: dragging holes in fills was not possible on Section and Elevation views
  • 169342 EDIT: Error message could come up when grouped elements were copied onto sections/elevations
  • 162337 EDIT: Find & Select: Copy Settings function didn't work in Section/Elevation
  • 166120 EDIT: Home story now correctly changes when hotlink drag a copy occurs in section
  • 165690 EDIT: Identical attributes are more accurately identified
  • 165685 EDIT: Image and gradient fills can now be overwritten in the attribute manager
  • 157260 EDIT: In section using "drag a copy" on a 2D object could change some of the line types in the object
  • 167134 EDIT: Openings could be multiplied but couldn't be elevated with the Drag action of the Multiply Pet Palette command
  • 170300 EDIT: Quick magnet selection was locked to one element in certain cases, regardless of the cursor's position in floor plan
  • 166124 EDIT: Relink a home story was made more robust
  • 158784 EDIT: Stretching an opening in composite wall gave incorrect feedback on Floor Plan.
  • 167778 EDIT: Switching to other Pet Palette options after using 'Elevate Mesh Point Height' was not possible.
  • 163806 EDIT: The "Multiply Rotate/distribute" command was not showing correct visual feedback upon the process of distributing the object
  • 166776 EDIT: Thermal Block assignment settings/Temperature Profiles were not stored with the project
  • 168858 EDIT: Vector fill became a solid grey upon minor zooming with the setting "scale with plan"
  • 166697 EDIT/CRASH: ArchiCAD could crash at creating or moving a polyline
  • 168362 EDIT/CRASH: ArchiCAD could crash at using the Tube function for editing a morph
  • 157822 EDIT/CRASH: In certain circumstances AC could crash while editing elements in 3D window
  • 170765 EDIT/FREEZE: Cursor movement over a spline that was in the vicinity of an arched edge as could be found in a roof could cause ArchiCAD to freeze
  • 168422 EDIT/SPEED: Editing a mesh item could be slower AC 17 then in AC 16
  • 171606 ENERGY EVALUATION: Incorrect overall R-values were calculated for openings
  • 166842 ENERGY EVALUATION: Total Area of openings between thermal blocks was calculated with double value.
  • 166024 FILE/DWG/EXPORT: Objects: Text settings in the object blocks were lost
  • 163905 FILE/DWG/EXPORT/ÖNORM: Only attributes with values were exported to DWG.
  • 163928 FILE/DWG/EXPORT/ÖNORM: Text settings of zones' text blocks were lost.
  • 168206 FILE/DWG/IMPORT: objects failed to open in Archicad 17, due to wrong algorythm in reading text objects
  • 161709 FILE/IFC/EXPORT: Certain GDL elements were exported to IFC without mapped geometry
  • 166764 FILE/IFC/EXPORT: The export was not successful if the username for the computer contained special national characters.
  • 169416 FILE/IFC/IMPORT: Certain walls with slanted end were imported with wrong geometry.
  • 150304 FILE/IFC/IMPORT: Infobox might have showed different elevation values than the Selection Settings dialog for certain elements.
  • 166937 FILE/IFC/IMPORT: Representation of elements imported from IFC were segmented on section/elevation compared to the 3D window.
  • 166198 FILE/IFC/IMPORT: The model did not appear in case of footprint IFC Site geometry description.
  • 162514 FILE/MIGRATION/MODEL: Intersection of walls was not correct when file migrated from AC16 to AC17
  • 170649 FILE/OPEN: An appropriate number of 30000 objects in the embedded library made files unworkable. The file did not edit or even open.
  • 167863 FILE/OPEN: Opening certain module files could result 'Invalid elements were found in this project error.'
  • 169858 FILE/PDF/SAVE: When rotated views were saved as PDF some text could be lost
  • 166162 FILE/SAVE: Walls with top links are now correctly handled when published to single story mod files
  • 171207 FILE/WRL/EXPORT: Syntax errors occured when .wrl file was saved with textures from the JPN version of ArchiCAD
  • 166841 EDIT: Guide line display no longer can cause performance problems on a Mac
  • 166787 HOTLINK: Cover Fill of Multi-plane Roofs could change when it was hotlinked into another file.
  • 164985 HOTLINK: IFC Assignments from the Module file could result in unsuccessful operation in the Host file.
  • 166143 HOTLINK: Non visible elements of a hotlink are now correctly handled when the hotlink is assigned a different story in section
  • 166139 MODEL: Doors, Windows with Variable Closure: The bottom and the top closures were at wrong position in case of profiled walls
  • 166839 MODEL: If two curved walls were connected an additional piece of wall appeared in 3D
  • 170956 MODEL: Objects created from a section (Create or Edit Patch) did not function in case of containing a building material
  • 170659 MODEL/ FREEZE: ArchiCAD could freeze when arcular planeroof and spline intersected each other
  • 170388 MODEL/FREEZE: ArchiCAD could freeze if the project contained lot of Solid Element Operations between model elements
  • 166604 MODEL/SPEED: Section generation might have been slow, when the project contained many gdl elements
  • 166945 SPEED: Navigation speed in 3D window has been improved
  • 164346 TEAMWORK/FREEZE: In special circumstances AC could freeze when regitestering modification in the Teamwork Server
  • 169869 TEAMWORK/MODEL: In teamwork under certain circumstances designed composite and profile thickness could differ from measured thickness.
  • 164887 TEAMWORK/SPEED: Joining a project in Teamwork caused slow BIM Server operation because of redundant checking algorythms
  • 166438 TEAMWORK: A change to a cut fill in a building material will no longer lead to invalid elements error in Teamwork
  • 169685 TEAMWORK: Elements could be ended up in locked state after working in Teamwork environment
  • 163813 TEAMWORK: Getting elements reserved - by another user assigning them - didn't initiate Receive and could cause inconsistent representation of data between the two users
  • 169476 TEAMWORK: Sending changes may have failed in rare situations
  • 170297 TEAMWORK: The firewall was erroneously activated due to the the usage of a reserved range TCP port
  • 161689 TEAMWORK: Warning of being in detached mode should always come up before loading the local cache
  • 167041 TEAMWORK: Trim of polyline will no longer cause invalid elements in teamwork.
  • 169745 USER INTERFACE: Better feedback is now given when switching between views
  • 167222 USER INTERFACE: Floor Plan view could flicker on layout if the Floor Plan Cut Plane was set to a height where it cut the bottom part of a Curtain Wall element.
  • 169211 USER INTERFACE: In 2D Camera mode 3Dconnexion Space Navigator Mouse worked in the wrong direction
  • 165709 USER INTERFACE: Profiled Beam: The Infobox didn't display the correct "elevation to project Zero" value, when the profile origo wasn't placed to the bottom of the profile
  • Issues solved since the release of Hotfix Build 5005:
  • 167510 CRASH: In Section/Elevation changing Renovation Status of elements or using Edit Selection Set tool crashed ArchiCAD. You can read more about the issue here: Troubleshooting/CrashAtRenovationStatusChange
  • 167673 CRASH: Opening particular files saved with previous hotfixes of ArchiCAD 17 and turning on trace could crash ArchiCAD.
  • 167760 CRASH: Opening schedules where in the criteria list parentheses were erroneously used caused crash.
  • Issues solved since the release of Hotfix Build 4008:
  • 162393 DOCUMENT: Full layouts and sections of particular projects could become rotated. You can read more about the issue here: Troubleshooting/RotatedLayoutsSections
  • 164080 DOCUMENT: If in the Work Environment the User Preference Schemes -> More Options -> Do not launch new instance of ArchiCAD when placing a view onto Layout setting was checked, drawings could not be placed, only an empty frame appeared.
  • 165550 DOCUMENT: Interactive Schedule didn't show the Integer value list properly.
  • 160250 DOCUMENT: mulitplane roof pitch was not listed properly.
  • 143997 DOCUMENT: Particular symbol fill could cause large PDF file.
  • 158237 DOCUMENT: PDF saved on Windows and opened in Preview on a MAC (or placed into ArchiCad) rendered unreadable text with faulty tracking. Read more about the issue here: Troubleshooting/UnreadablePdf
  • 166656 DOCUMENT: Rendered image could be black in Lightworks, if 3D Cutaway blocked Sun and Sky objects.
  • 159404 DOCUMENT: Reviewer did notwork with newer Java applets.
  • 159411 DOCUMENT: Some Master Layouts hid Elements with New Renovation Status.
  • 148152 DOCUMENT: When listing objects in Interactive Schedule there was no criteria referring the Zone that they were placed in.
  • 158118 DOCUMENT: Zones which were overridden by renovation and MVO lost their renovation override style in the saved and printed pdf.
  • 163334 EDIT: Align Texture was working erroneously with curved and slanted beams.
  • 163331 EDIT: Aling Texture's Set Origin worked erroneously on curved walls.
  • 158581 EDIT: Changed IFC properties weren't kept when saving a Favorite from the Element.
  • 161572 EDIT: After copy-pasting Story-linked elements to the upmost story, they loose their linked status.
  • 161862 EDIT: Crash could occur when adjusting Editing plane.
  • 165558 EDIT: Editing a mesh could cause crash.
  • 165270 EDIT: First floor could not be selected as scheduling criteria in the following language versions: CZE, CHI, JPN, NOR, RUS, USA
  • 164347 EDIT: Force Guide Line command didn't work with the Door, Window tools.
  • 161123, 162933 EDIT: If a parameter of an object was changed in section or elevation view, when switched to another section/elevation view the object would not be updated.
  • 160818 EDIT: If Resize command was used repeatedly to modify an element, Resize ratio values once set were not retained in the element's pop-up window.
  • 164149 EDIT: If you mirror a fill with the Area text display on then after editing the mirrored fill the area text got dispositioned.
  • 163894 EDIT: In section selecting and changing grouped elements did not have an effect on the invisible elements.
  • 165052 EDIT: Placing Doors and Windows Using Special Snap Constraint went wrong when guide line was active.
  • 162129 EDIT: Position of a traced detail on another detail view could be inconsistent.
  • 157406 EDIT: Status of zones with geometry method changed from "Manual" to "Inner Edge" were incorrect and they couldn't be updated.
  • 160927 EDIT: Surface renovation override did not work for Morph.
  • 163783 EDIT: Updating zones could cause crash in certain situations.
  • 160814 EDIT: When heights of hotspots of mesh were edited one after the other the last used command were not retained by Pet Palette.
  • 160310, 163982 EDIT: Windows with Custom Corner and Corner Windows were not placed where the first feedback showed.
  • 163889 EDIT: Could not paste rich text or figure into ArchiCAD.
  • 159768 ENERGY EVALUATION: Central Boiler Unmet Load Hours was erroneously calculated under certain circumstances.
  • 161508 ENERGY EVALUATION: Cooling's and Ventilation's auxiliary system data were missing from Report.xls.
  • 160025 ENERGY EVALUATION: Default system characteristics of a new cooling machine were wrong.
  • 165033 ENERGY EVALUATION: Discrepancy could appear in solar radiation percentage of openings.
  • 165218 ENERGY EVALUATION: Energy Evaluation calculation didn't finish and an error message appeared.
  • 160923 ENERGY EVALUATION: In particular files sewage calculation was wrong if Local Heat Pump was used for Service Hot Water Generation.
  • 162053 ENERGY EVALUATION: Service Hot Water Heating and Sewage didn't appear on the Energy Balance in certain circumstances.
  • 159888 ENERGY EVALUATION: Setting BoilerSystem -> Heat Loss value could cause erroneous efects on the simulation result.
  • 165258 ENERGY EVALUATION: Solar absorptance unit was missing in case of Tree View
  • 166044 ENERGY EVALUATION: Switching between radio buttons on the Climate Data dialog could crash ArchiCAD.
  • 161037 ENERGY EVALUATION: The Cooling quantity in the report didn't match with the quantity in the xls.
  • 161507 ENERGY EVALUATION: The Target of the Renewable Energy Source was missing from the 2nd and 3rd bar charts of the Report.PDF's Energy Consumption by Sources chapter, if Heat Pump or Solar collector is used for heating.
  • 163880 ENERGY EVALUATION: Warning message could appear in Energy evaluation because some polygons weren't segmented.
  • 161509 ENERGY EVALUATION: With particular file Auxiliary Electricity appears on Report.pdf if District Cooling was used.
  • 160058 ENERGY EVALUATION: With particular file Central Cooling Machine was unable to meet cooling demand, even with maximum capacity.
  • 161589 ENERGY EVALUATION: With particular file Cooling Energy Quantity was wrong in the Energy Consumption chapters of the Report.pdf.
  • 160922 ENERGY EVALUATION: With particular file Energy Consumption calculation of Heat Pumps used for Service Hot Water Heating was wrong.
  • 161454 ENERGY EVALUATION: With particular file Energy source and target quantities were wrong on Report.pdf if cooling machine was used.
  • 161465 ENERGY EVALUATION: With particular file Peak Cooling data was wrong on Report.pdf if cooling machine was used.
  • 161489 ENERGY EVALUATION: With particular file Primary Energy calculation of heat pump for heating was wrong.
  • 160944 ENERGY EVALUATION: With particular file Sewage calculation was wrong if Central Heat Pump was used for Service Hot Water Generation.
  • 162001 ENERGY EVALUATION: With particular file Solar Collector Type setting had no effect on calculation.
  • 163905 FILE/DWG/EXPORT/ÖNORM: Only attributes with values were exported to DWG.
  • 163928 FILE/DWG/EXPORT/ÖNORM: Text settings of zones' text blocks were lost.
  • 163191 FILE/DWG/EXPORT: A specific combination of template and translator settings caused DWG export to resulte in a 0kb faulty DWG file.
  • 165560 FILE/DWG/IMPORT: Relinking, opening DWG could cause crash.
  • 159637 FILE/EXPORT/PDF: Trace Reference wasn't exported to PDF if Rotated Orientation was set and there were Elements far from Origin.
  • 164938 FILE/EXPORT/SKETCHUP: Usage of national characters in the add-ons directory resulted in the export of a 0 kb sketchup file.
  • 164496 FILE/IFC: Improved export and import of large models.
  • 159569 FILE/IFC/EXPORT: Element quantities can be exported into custom properties. Read more about this here: RegistryKeys/ArchiCADQuantities
  • 162596 FILE/IFC/EXPORT: IFC Quantities 'GrossFloorArea' and 'NetFloorArea' were switched upon IFC export.
  • 143209 FILE/IFC/EXPORT: Openings with slanted reveal might look incorrect in IFC.
  • 161549 FILE/IFC/EXPORT: Warning message that "Some elements could not be exported due to missing geometry" appeared after exporting empty openings.
  • 163271 FILE/IFC/IMPORT: After importing a particular IFC file 2D symbol of doors were missing and viewing their settings brought up error message.
  • 165612 FILE/IFC/IMPORT: If the column settings in the default template had a veneer, IFC imported columns would inherit this veneer.
  • 147046 FILE/IFC/IMPORT: Wall niche became an opening when imported into ArchiCAD.
  • 161699 FILE/MIGRATION: After migrating a file containing elements very far from the origin the coordinates of elements could double.
  • 165203 FREEZE: A mouse clicked in certain regions close to a spline could make ArchiCAD unresponsive.
  • 163057 FREEZE: Non-responsive behaviour occurred when background processing of 3d elements refused to allow user interaction.
  • 160731 FREEZE: On Mac ArchiCAD seemed to be freezing due to the fact that the publishing window came back behind the main ArchiCAD window after switching between applications.
  • 163391 GDL: CALL function couldn't be rebuild, when it was used for macro name.
  • 163963 HOTLINK: Hotlink update did not work with particular file.
  • 161479 HOTLINK: In the Host file Hotlinked Zones weren't scheduled properly. Several Zone parameters appeared to be 0 instead of the real value.
  • 161045 HOTLINK/LIBRARY HANDLING: Deleted or broken Hotlink's Embedded library couldn't be removed from the Host file.
  • 163791 INSTALL: Hotfix or additional installations could only be made by the same user who had installed ArchiCAD because limted permission of the newly created folders.
  • 163409 MODEL: After deleting a wall and then undoing the operation the original intersection geometry with a roof was not restored.
  • 157576 MODEL: Align 3D command didn't work on polygonal Walls.
  • 161498 MODEL: Align 3D Texture commands had no effect on Beams.
  • 162032 MODEL: Checking and correcting code was added to better handle 3D junction data.
  • 161832 MODEL: Curved beams didn't cut walls.
  • 163209 MODEL: Sun and sky objects did not work with marquee.
  • 165856 MODEL: textures with alpha channel appeared incorrectly with black patches on OS X 10.9 Mavericks.
  • 165619 MODEL: When a Wall-end was placed with a height parameter lower then the floor cut plane, window related error message erroneously appeared.
  • 156754 SPEED: Slowdown or freeze could happen while having multiple ArchiCAD instances running side by side.
  • 164880 TEAMWORK: Changing Elevation Dimension' level wasn't send to the server, thus different teammates could see different Dimensions.
  • 165880 TEAMWORK: In special cases level dimensions could be sources of Teamwork join errors
  • 159171 TEAMWORK: Project backups created with previous versions could not be imported in BIM Server Manager
  • 161576 TEAMWORK: There were GDL elements that could make a file sharable, but not joinable.
  • 162760 TEAMWORK/EDIT: Composites could be edited while not reserved in TW.
  • 160546 TEAMWORK/FREEZE: If many people were active in a teamwork project, one viewer of an Interactive Schedules could experience erratic scrolling and/or non-responsive behavior.
  • 156759 USER INTERFACE: Navigating in 2D using 3Dconnexion Space Navigator worked in wrong direction.
  • 165663 USER INTERFACE: When using ArchiCAD on two displays palettes with left side title bar could get inaccessible on MAC OS X 10.9 after dragging them to the border area between two displays.

New in ArchiCAD 17.0 Build 5014 Hotfix 5 (Jan 21, 2014)

  • Fixed regression crashes introduced with Hotfix 4 (build 5005):
  • 167510 CRASH: In Section/Elevation changing Renovation Status of elements or using Edit Selection Set tool crashed ArchiCAD.
  • 167673 CRASH: Opening particular files saved with previous hotfixes of ArchiCAD 17 and turning on trace could crash ArchiCAD.
  • 167760 CRASH: Opening schedules where in the criteria list parentheses were erroneously used caused crash.
  • Bugs fixed in comparison to Hotfix 3 (build 4008):
  • 162393 DOCUMENT: Full layouts and sections of particular projects could become rotated.
  • 164080 DOCUMENT: If in the Work Environment the User Preference Schemes -> More Options -> Do not launch new instance of ArchiCAD when placing a view onto Layout setting was checked, drawings could not be placed, only an empty frame appeared.
  • 165550 DOCUMENT: Interactive Schedule didn't show the Integer value list properly.
  • 160250 DOCUMENT: mulitplane roof pitch was not listed properly.
  • 143997 DOCUMENT: Particular symbol fill could cause large PDF file.
  • 158237 DOCUMENT: PDF saved on Windows and opened in Preview on a MAC (or placed into ArchiCad) rendered unreadable text with faulty tracking.
  • 166656 DOCUMENT: Rendered image could be black in Lightworks, if 3D Cutaway blocked Sun and Sky objects.
  • 159404 DOCUMENT: Reviewer did notwork with newer Java applets.
  • 159411 DOCUMENT: Some Master Layouts hid Elements with New Renovation Status.
  • 148152 DOCUMENT: When listing objects in Interactive Schedule there was no criteria referring the Zone that they were placed in.
  • 158118 DOCUMENT: Zones which were overridden by renovation and MVO lost their renovation override style in the saved and printed pdf.
  • 163334 EDIT: Align Texture was working erroneously with curved and slanted beams.
  • 163331 EDIT: Aling Texture's Set Origin worked erroneously on curved walls.
  • 158581 EDIT: Changed IFC properties weren't kept when saving a Favorite from the Element.
  • 161572 EDIT: After copy-pasting Story-linked elements to the upmost story, they loose their linked status.
  • 161862 EDIT: Crash could occur when adjusting Editing plane.
  • 165558 EDIT: Editing a mesh could cause crash.
  • 165270 EDIT: First floor could not be selected as scheduling criteria in the following language versions: CZE, CHI, JPN, NOR, RUS, USA
  • 164347 EDIT: Force Guide Line command didn't work with the Door, Window tools.
  • 161123, 162933 EDIT: If a parameter of an object was changed in section or elevation view, when switched to another section/elevation view the object would not be updated.
  • 160818 EDIT: If Resize command was used repeatedly to modify an element, Resize ratio values once set were not retained in the element's pop-up window.
  • 164149 EDIT: If you mirror a fill with the Area text display on then after editing the mirrored fill the area text got dispositioned.
  • 163894 EDIT: In section selecting and changing grouped elements did not have an effect on the invisible elements.
  • 165052 EDIT: Placing Doors and Windows Using Special Snap Constraint went wrong when guide line was active.
  • 162129 EDIT: Position of a traced detail on another detail view could be inconsistent.
  • 157406 EDIT: Status of zones with geometry method changed from "Manual" to "Inner Edge" were incorrect and they couldn't be updated.
  • 160927 EDIT: Surface renovation override did not work for Morph.
  • 163783 EDIT: Updating zones could cause crash in certain situations.
  • 160814 EDIT: When heights of hotspots of mesh were edited one after the other the last used command were not retained by Pet Palette.
  • 160310, 163982 EDIT: Windows with Custom Corner and Corner Windows were not placed where the first feedback showed.
  • 163889 EDIT: Could not paste rich text or figure into ArchiCAD.
  • 159768 ENERGY EVALUATION: Central Boiler Unmet Load Hours was erroneously calculated under certain circumstances.
  • 161508 ENERGY EVALUATION: Cooling's and Ventilation's auxiliary system data were missing from Report.xls.
  • 160025 ENERGY EVALUATION: Default system characteristics of a new cooling machine were wrong.
  • 165033 ENERGY EVALUATION: Discrepancy could appear in solar radiation percentage of openings.
  • 165218 ENERGY EVALUATION: Energy Evaluation calculation didn't finish and an error message appeared.
  • 160923 ENERGY EVALUATION: In particular files sewage calculation was wrong if Local Heat Pump was used for Service Hot Water Generation.
  • 162053 ENERGY EVALUATION: Service Hot Water Heating and Sewage didn't appear on the Energy Balance in certain circumstances.
  • 159888 ENERGY EVALUATION: Setting BoilerSystem -> Heat Loss value could cause erroneous efects on the simulation result.
  • 165258 ENERGY EVALUATION: Solar absorptance unit was missing in case of Tree View
  • 166044 ENERGY EVALUATION: Switching between radio buttons on the Climate Data dialog could crash ArchiCAD.
  • 161037 ENERGY EVALUATION: The Cooling quantity in the report didn't match with the quantity in the xls.
  • 161507 ENERGY EVALUATION: The Target of the Renewable Energy Source was missing from the 2nd and 3rd bar charts of the Report.PDF's Energy Consumption by Sources chapter, if Heat Pump or Solar collector is used for heating.
  • 163880 ENERGY EVALUATION: Warning message could appear in Energy evaluation because some polygons weren't segmented.
  • 161509 ENERGY EVALUATION: With particular file Auxiliary Electricity appears on Report.pdf if District Cooling was used.
  • 160058 ENERGY EVALUATION: With particular file Central Cooling Machine was unable to meet cooling demand, even with maximum capacity.
  • 161589 ENERGY EVALUATION: With particular file Cooling Energy Quantity was wrong in the Energy Consumption chapters of the Report.pdf.
  • 160922 ENERGY EVALUATION: With particular file Energy Consumption calculation of Heat Pumps used for Service Hot Water Heating was wrong.
  • 161454 ENERGY EVALUATION: With particular file Energy source and target quantities were wrong on Report.pdf if cooling machine was used.
  • 161465 ENERGY EVALUATION: With particular file Peak Cooling data was wrong on Report.pdf if cooling machine was used.
  • 161489 ENERGY EVALUATION: With particular file Primary Energy calculation of heat pump for heating was wrong.
  • 160944 ENERGY EVALUATION: With particular file Sewage calculation was wrong if Central Heat Pump was used for Service Hot Water Generation.
  • 162001 ENERGY EVALUATION: With particular file Solar Collector Type setting had no effect on calculation.
  • 163905 FILE/DWG/EXPORT/ÖNORM: Only attributes with values were exported to DWG.
  • 163928 FILE/DWG/EXPORT/ÖNORM: Text settings of zones' text blocks were lost.
  • 163191 FILE/DWG/EXPORT: A specific combination of template and translator settings caused DWG export to resulte in a 0kb faulty DWG file.
  • 165560 FILE/DWG/IMPORT: Relinking, opening DWG could cause crash.
  • 159637 FILE/EXPORT/PDF: Trace Reference wasn't exported to PDF if Rotated Orientation was set and there were Elements far from Origin.
  • 164938 FILE/EXPORT/SKETCHUP: Usage of national characters in the add-ons directory resulted in the export of a 0 kb sketchup file.
  • 164496 FILE/IFC: Improved export and import of large models.
  • 159569 FILE/IFC/EXPORT: Element quantities can be exported into custom properties.
  • 162596 FILE/IFC/EXPORT: IFC Quantities 'GrossFloorArea' and 'NetFloorArea' were switched upon IFC export.
  • 143209 FILE/IFC/EXPORT: Openings with slanted reveal might look incorrect in IFC.
  • 161549 FILE/IFC/EXPORT: Warning message that "Some elements could not be exported due to missing geometry" appeared after exporting empty openings.
  • 163271 FILE/IFC/IMPORT: After importing a particular IFC file 2D symbol of doors were missing and viewing their settings brought up error message.
  • 165612 FILE/IFC/IMPORT: If the column settings in the default template had a veneer, IFC imported columns would inherit this veneer.
  • 147046 FILE/IFC/IMPORT: Wall niche became an opening when imported into ArchiCAD.
  • 161699 FILE/MIGRATION: After migrating a file containing elements very far from the origin the coordinates of elements could double.
  • 165203 FREEZE: A mouse clicked in certain regions close to a spline could make ArchiCAD unresponsive.
  • 163057 FREEZE: Non-responsive behaviour occurred when background processing of 3d elements refused to allow user interaction.
  • 160731 FREEZE: On Mac ArchiCAD seemed to be freezing due to the fact that the publishing window came back behind the main ArchiCAD window after switching between applications.
  • 163391 GDL: CALL function couldn't be rebuild, when it was used for macro name.
  • 163963 HOTLINK: Hotlink update did not work with particular file.
  • 161479 HOTLINK: In the Host file Hotlinked Zones weren't scheduled properly. Several Zone parameters appeared to be 0 instead of the real value.
  • 161045 HOTLINK/LIBRARY HANDLING: Deleted or broken Hotlink's Embedded library couldn't be removed from the Host file.
  • 163791 INSTALL: Hotfix or additional installations could only be made by the same user who had installed ArchiCAD because limted permission of the newly created folders.
  • 163409 MODEL: After deleting a wall and then undoing the operation the original intersection geometry with a roof was not restored.
  • 157576 MODEL: Align 3D command didn't work on polygonal Walls.
  • 161498 MODEL: Align 3D Texture commands had no effect on Beams.
  • 162032 MODEL: Checking and correcting code was added to better handle 3D junction data.
  • 161832 MODEL: Curved beams didn't cut walls.
  • 163209 MODEL: Sun and sky objects did not work with marquee.
  • 165856 MODEL: textures with alpha channel appeared incorrectly with black patches on OS X 10.9 Mavericks.
  • 165619 MODEL: When a Wall-end was placed with a height parameter lower then the floor cut plane, window related error message erroneously appeared.
  • 156754 SPEED: Slowdown or freeze could happen while having multiple ArchiCAD instances running side by side.
  • 164880 TEAMWORK: Changing Elevation Dimension' level wasn't send to the server, thus different teammates could see different Dimensions.
  • 165880 TEAMWORK: In special cases level dimensions could be sources of Teamwork join errors
  • 159171 TEAMWORK: Project backups created with previous versions could not be imported in BIM Server Manager
  • 161576 TEAMWORK: There were GDL elements that could make a file sharable, but not joinable.
  • 162760 TEAMWORK/EDIT: Composites could be edited while not reserved in TW.
  • 160546 TEAMWORK/FREEZE: If many people were active in a teamwork project, one viewer of an Interactive Schedules could experience erratic scrolling and/or non-responsive behavior.
  • 156759 USER INTERFACE: Navigating in 2D using 3Dconnexion Space Navigator worked in wrong direction.
  • 165663 USER INTERFACE: When using ArchiCAD on two displays palettes with left side title bar could get inaccessible on MAC OS X 10.9 after dragging them to the border area between two displays.

New in ArchiCAD 17.0 Build 5005 Hotfix 4 (Dec 12, 2013)

  • DOCUMENT: Full layouts and sections of particular projects could become rotated.
  • DOCUMENT: If in the Work Environment the User Preference Schemes -> More Options -> Do not launch new instance of ArchiCAD when placing a view onto Layout setting was checked, drawings could not be placed, only an empty frame appeared.
  • DOCUMENT: Interactive Schedule didn't show the Integer value list properly.
  • DOCUMENT: mulitplane roof pitch was not listed properly.
  • DOCUMENT: Particular symbol fill could cause large PDF file.
  • DOCUMENT: PDF saved on Windows and opened in Preview on a MAC (or placed into ArchiCad) rendered unreadable text with faulty tracking.
  • DOCUMENT: Rendered image could be black in Lightworks, if 3D Cutaway blocked Sun and Sky objects.
  • DOCUMENT: Reviewer did notwork with newer Java applets.
  • DOCUMENT: Some Master Layouts hid Elements with New Renovation Status.
  • DOCUMENT: When listing objects in Interactive Schedule there was no criteria referring the Zone that they were placed in.
  • DOCUMENT: Zones which were overridden by renovation and MVO lost their renovation override style in the saved and printed pdf.
  • EDIT: Align Texture was working erroneously with curved and slanted beams.
  • EDIT: Aling Texture's Set Origin worked erroneously on curved walls.
  • EDIT: Changed IFC properties weren't kept when saving a Favorite from the Element.
  • EDIT: After copy-pasting Story-linked elements to the upmost story, they loose their linked status.
  • EDIT: Crash could occur when adjusting Editing plane.
  • EDIT: Editing a mesh could cause crash.
  • EDIT: First floor could not be selected as scheduling criteria in the following language versions: CZE, CHI, JPN, NOR, RUS, USA
  • EDIT: Force Guide Line command didn't work with the Door, Window tools.
  • , 162933 EDIT: If a parameter of an object was changed in section or elevation view, when switched to another section/elevation view the object would not be updated.
  • EDIT: If Resize command was used repeatedly to modify an element, Resize ratio values once set were not retained in the element's pop-up window.
  • EDIT: If you mirror a fill with the Area text display on then after editing the mirrored fill the area text got dispositioned.
  • EDIT: In section selecting and changing grouped elements did not have an effect on the invisible elements.
  • EDIT: Placing Doors and Windows Using Special Snap Constraint went wrong when guide line was active.
  • EDIT: Position of a traced detail on another detail view could be inconsistent.
  • EDIT: Status of zones with geometry method changed from "Manual" to "Inner Edge" were incorrect and they couldn't be updated.
  • EDIT: Surface renovation override did not work for Morph.
  • EDIT: Updating zones could cause crash in certain situations.
  • EDIT: When heights of hotspots of mesh were edited one after the other the last used command were not retained by Pet Palette.
  • , 163982 EDIT: Windows with Custom Corner and Corner Windows were not placed where the first feedback showed.
  • EDIT: Could not paste rich text or figure into ArchiCAD.
  • ENERGY EVALUATION: Central Boiler Unmet Load Hours was erroneously calculated under certain circumstances.
  • ENERGY EVALUATION: Cooling's and Ventilation's auxiliary system data were missing from Report.xls.
  • ENERGY EVALUATION: Default system characteristics of a new cooling machine were wrong.
  • ENERGY EVALUATION: Discrepancy could appear in solar radiation percentage of openings.
  • ENERGY EVALUATION: Energy Evaluation calculation didn't finish and an error message appeared.
  • ENERGY EVALUATION: In particular files sewage calculation was wrong if Local Heat Pump was used for Service Hot Water Generation.
  • ENERGY EVALUATION: Service Hot Water Heating and Sewage didn't appear on the Energy Balance in certain circumstances.
  • ENERGY EVALUATION: Setting BoilerSystem -> Heat Loss value could cause erroneous efects on the simulation result.
  • ENERGY EVALUATION: Solar absorptance unit was missing in case of Tree View
  • ENERGY EVALUATION: Switching between radio buttons on the Climate Data dialog could crash ArchiCAD.
  • ENERGY EVALUATION: The Cooling quantity in the report didn't match with the quantity in the xls.
  • ENERGY EVALUATION: The Target of the Renewable Energy Source was missing from the 2nd and 3rd bar charts of the Report.PDF's Energy Consumption by Sources chapter, if Heat Pump or Solar collector is used for heating.
  • ENERGY EVALUATION: Warning message could appear in Energy evaluation because some polygons weren't segmented.
  • ENERGY EVALUATION: With particular file Auxiliary Electricity appears on Report.pdf if District Cooling was used.
  • ENERGY EVALUATION: With particular file Central Cooling Machine was unable to meet cooling demand, even with maximum capacity.
  • ENERGY EVALUATION: With particular file Cooling Energy Quantity was wrong in the Energy Consumption chapters of the Report.pdf.
  • ENERGY EVALUATION: With particular file Energy Consumption calculation of Heat Pumps used for Service Hot Water Heating was wrong.
  • ENERGY EVALUATION: With particular file Energy source and target quantities were wrong on Report.pdf if cooling machine was used.
  • ENERGY EVALUATION: With particular file Peak Cooling data was wrong on Report.pdf if cooling machine was used.
  • ENERGY EVALUATION: With particular file Primary Energy calculation of heat pump for heating was wrong.
  • ENERGY EVALUATION: With particular file Sewage calculation was wrong if Central Heat Pump was used for Service Hot Water Generation.
  • ENERGY EVALUATION: With particular file Solar Collector Type setting had no effect on calculation.
  • FILE/DWG/EXPORT/ÖNORM: Only attributes with values were exported to DWG.
  • FILE/DWG/EXPORT/ÖNORM: Text settings of zones' text blocks were lost.
  • FILE/DWG/EXPORT: A specific combination of template and translator settings caused DWG export to resulte in a 0kb faulty DWG file.
  • FILE/DWG/IMPORT: Relinking, opening DWG could cause crash.
  • FILE/EXPORT/PDF: Trace Reference wasn't exported to PDF if Rotated Orientation was set and there were Elements far from Origin.
  • FILE/EXPORT/SKETCHUP: Usage of national characters in the add-ons directory resulted in the export of a 0 kb sketchup file.
  • FILE/IFC: Improved export and import of large models.
  • FILE/IFC/EXPORT: Element quantities can be exported into custom properties.
  • FILE/IFC/EXPORT: IFC Quantities 'GrossFloorArea' and 'NetFloorArea' were switched upon IFC export.
  • FILE/IFC/EXPORT: Openings with slanted reveal might look incorrect in IFC.
  • FILE/IFC/EXPORT: Warning message that "Some elements could not be exported due to missing geometry" appeared after exporting empty openings.
  • FILE/IFC/IMPORT: After importing a particular IFC file 2D symbol of doors were missing and viewing their settings brought up error message.
  • FILE/IFC/IMPORT: If the column settings in the default template had a veneer, IFC imported columns would inherit this veneer.
  • FILE/IFC/IMPORT: Wall niche became an opening when imported into ArchiCAD.
  • FILE/MIGRATION: After migrating a file containing elements very far from the origin the coordinates of elements could double.
  • FREEZE: A mouse clicked in certain regions close to a spline could make ArchiCAD unresponsive.
  • FREEZE: Non-responsive behaviour occurred when background processing of 3d elements refused to allow user interaction.
  • FREEZE: On Mac ArchiCAD seemed to be freezing due to the fact that the publishing window came back behind the main ArchiCAD window after switching between applications.
  • GDL: CALL function couldn't be rebuild, when it was used for macro name.
  • HOTLINK: Hotlink update did not work with particular file.
  • HOTLINK: In the Host file Hotlinked Zones weren't scheduled properly. Several Zone parameters appeared to be 0 instead of the real value.
  • HOTLINK/LIBRARY HANDLING: Deleted or broken Hotlink's Embedded library couldn't be removed from the Host file.
  • INSTALL: Hotfix or additional installations could only be made by the same user who had installed ArchiCAD because limted permission of the newly created folders.
  • MODEL: After deleting a wall and then undoing the operation the original intersection geometry with a roof was not restored.
  • MODEL: Align 3D command didn't work on polygonal Walls.
  • MODEL: Align 3D Texture commands had no effect on Beams.
  • MODEL: Checking and correcting code was added to better handle 3D junction data.
  • MODEL: Curved beams didn't cut walls.
  • MODEL: Sun and sky objects did not work with marquee.
  • MODEL: When a Wall-end was placed with a height parameter lower then the floor cut plane, window related error message erroneously appeared.
  • SPEED: Slowdown or freeze could happen while having multiple ArchiCAD instances running side by side.
  • TEAMWORK: Changing Elevation Dimension' level wasn't send to the server, thus different teammates could see different Dimensions.
  • TEAMWORK: In special cases level dimensions could be sources of Teamwork join errors
  • TEAMWORK: Project backups created with previous versions could not be imported in BIM Server Manager
  • TEAMWORK: There were GDL elements that could make a file sharable, but not joinable.
  • TEAMWORK/EDIT: Composites could be edited while not reserved in TW.
  • TEAMWORK/FREEZE: If many people were active in a teamwork project, one viewer of an Interactive Schedules could experience erratic scrolling and/or non-responsive behavior.
  • USER INTERFACE: Navigating in 2D using 3Dconnexion Space Navigator worked in wrong direction.

New in ArchiCAD 17.0 Build 4008 Hotfix 3 (Oct 22, 2013)

  • ArchiCAD 17 Hotfix 3 Build 4008 contains various fixes and improvements necessary to introduce full BIMx Hyper-model support to ArchiCAD 17. The brand new BIMx Hyper-model publishing allows complete BIM documentation (3D models as well as 2D drawings) to be shared for use on iOS devices such as the iPhone/iPad.

New in ArchiCAD 17.0 Build 4005 Hotfix 2 (Sep 17, 2013)

  • List of bugs fixed in this Hotfix:
  • 156094 API: Transformation data of rotated views could not be retrieved or set through API.
  • 131177 CRASH: ArchiCAD could crash during IFC export.
  • 155118 CRASH: The routines that addressed 3D projections were made more stable.
  • 157462 CRASH: In particular projects opening the project or pasting 2D elements could cause ArchiCAD to crash.
  • 157557 CRASH: Crash could occur when stretching a Fill with the Marquee tool.
  • 159613 CRASH: Both an erroneous visible ArchiCAD Layer and its resulting crash were corrected.
  • 159685 CRASH: Crash could occur when starting energy simulation.
  • 161434 CRASH: Some files containing incorrect wall/slab junction points caused ArchiCAD to crash on open.
  • 158319 CRASH (FRA): French ArchiCAD could crash when rendering with Sketch engine.
  • 134515 DOCUMENT: Display of Beams did not reflect the position of the Floor Plan Cut Plane below and above the Home Story.
  • 148311 DOCUMENT: Story numbers were also visible in Schedule fields that should have shown only the names.
  • 157548 DOCUMENT: Built in common Interior Elevation Marker displayed incorrect outer references. All the references were the same.
  • 159140 DOCUMENT: Zone Category was not listed in the Schedule.
  • 160332 DOCUMENT: On MAC OS platforms Energy Evaluation report could not be saved in some localized version (RUS, POL).
  • 158545 DOCUMENT (JPN): ± sign appeared incorrectly in the Interactive Schedule of JPN version.
  • 145593 EDIT: Interior Elevation Marker was rotated when limit line was extended.
  • 148586 EDIT: Preview of materials could disappear when switching between different rendering engines in the Surface Settings dialog.
  • 156091 EDIT: In Section/Elevation when modifying a wall using the pet palette Stretch Height command, numeric values entered into the tracker's Offset to Home Story or Offset to Top Linked Story fields were ignored.
  • 156273 EDIT: Unnecessary hotspots could appear on roofs.
  • 157183 EDIT: If fill was mirrored before in a given view, and the view is then rotated by more than 90 degrees then the fill's area text would not be dragged to the desired position.
  • 157639 EDIT: After activating a Morph favorite, the layer and Building Material was not transferred.
  • 158203 EDIT: Relink Home Story didn't work for grouped elements unless the group is suspended.
  • 158535 EDIT: Morph favoritesweren't applied when using double clicking.
  • 159537 EDIT: Adjust function didn't work between walls and other elemet types.
  • 159747 EDIT: Automatic Story association changes when accidentally moving the element across the story level line in Section/Elevation
  • 160131 EDIT: If cutting plane was defined in 3D, the snap points of the Stories on the guide line were not available.
  • 160137 EDIT: object created from a section (Create Patch) could not be edited because it contained a Building Material.
  • 160184 EDIT: Fill Orientation of Building Materials could change if more than one was selected in the dialog.
  • 160553 EDIT: Markup Style field picked up attributes unnecessarily with every copy/paste.
  • 161472 EDIT/CRASH: ArchiCAD could crash if a Story containing a Hotlink was deleted.
  • 159364 EDIT/DOCUMENT: Modifying Wall Reference Line did not automatically update dimensions associated to the wall. Only moving an end-point of the wall triggered the update.
  • 157956 EDIT/HOTLINK: Multi story Hotlink Module could not be pasted to a different story.
  • 157437 EDIT (NOR): Space Saver Staircase couldn't be placed in NOR version.
  • 157537 ENERGY EVALUATION: When autotext was inserted into the header/footer of the Evaluation Report, it could delete the existing content.
  • 158400 ENERGY EVALUATION: The energy demand of Auxiliary System could be erroneously calculated.
  • 158654 ENERGY EVALUATION: Solar Analysis didn't work with windows shown with a single surface in simple viewing method.
  • 158880 ENERGY EVALUATION: When importing Operation Profile attributes their Internal temperature Min/Max values were reset to off.
  • 160106 ENERGY EVALUATION: In some particular circumstances solar radiation calculation for windows could give wrong results.
  • 160233 ENERGY EVALUATION: After running solar analysis the leaves of a plant object disappeared. Placing the element again didn't help.
  • 157933 ENERGY EVALUATION/TEAMWORK: Several Energy Evaluation settings could be changed even without reserving them first.
  • 159657 FILE/ARTLANTIS/SAVE: ArchiCAD 17 could not save Artlantis 4.1 file if another Artlantis 4.1 file was used as reference.
  • 158717 FILE/DWG/EXPORT (AUT): Certain objects could be exported to dwg file with wrong sizes if ÖNORM translator were used.
  • 158352 FILE/DWG/IMPORT: Import Blocks from DXF/DWG caused ArchiCAD to crash.
  • 147239 FILE/IFC/DATA: Find & Select and Interactive Element Schedule work for IFC Type Product and IFC assignments data.
  • 156971 FILE/IFC/DATA: The Merge function of the IFC Scheme Setup command now opens the IFC Schemes 17 folder by default.
  • 160970 FILE/IFC/DATA: IFC name attribute was not descriptive enough. A mapping file was created that is user modifiable that contains a set of rules formatted in xml to bring data from different fields in an ArchiCAD project into the IFC Name Attribute field.
  • 161707 FILE/IFC/DATA: If there is no active MEP Modeler Add-On, the properties of MEP-type elements were not saved after clicking 'OK' in the Element Settings dialog.
  • 159906 FILE/IFC/EXPORT: Extended Model View export now can be made based on Coordination View 2.0 using a registry key.
  • 161208 FILE/IFC/EXPORT: After opening a particular IFC file exported from ArchiCAD 17 in Revit 2014, the width values of some doors show 0.9 mm instead of 900 mm.
  • 158841 FILE/IFC/IMPORT: Space Containment data of zones are now imported even if the Zone itself cannot be imported.
  • 159199 FILE/IFC/IMPORT: At IFC import IFC Container elements were not correctly registered which in some cases could lead to TW errors.
  • 159286 FILE/IFC/IMPORT: ArchiCAD crashed when opening particular IFC file.
  • 159431 FILE/IFC/IMPORT: Certain IFC files could be opened in ArchiCAD 16 but not in 17.
  • 160068 FILE/IFC/IMPORT: Elements that were part of a Space Container were not imported if that particular space did not have a geometry.
  • 161503 FILE/IFC/IMPORT: IfcWalls defined in a specific coordination system were placed with incorrect position upon import.
  • 159536 FILE/IMPORT: Import standard Steel Profile: Unit display was not correct, the decimal separator was at wrong place in case of cm's
  • 156934 FILE/MIGRATION: Projected display of particular user created windows could differ in ArchiCAD 17 after migrating the file from previous ArchiCAD versions.
  • 159812 FILE/OPEN: File couldn't be opened if it contained a Roof having 0 length Pivot line.
  • 161157 FILE/OPEN: Arch Length dimensions placed in ArchiCAD 16 could cause the plan ti fail to open in ArchiCAD 17.
  • 159954 FILE/OPEN/CRASH: File could crash at opening if it contained invalid polygons. (Polylines/Fills with nodes too close to each other)
  • 148255 INSTALL: Hotfix installation on the BIM Server could fail if multiple users are logged into the server OS.
  • 159675 INSTALL: Windows could mark the hotfix installer as being published by Unknown source. The digital signature of GRAPHISOFT has been corrected.
  • 161723 INSTALL: The hotfix installer didn't find any installed ArchiCAD instances if ArchiCAD's .plist files were damaged.
  • 162575 INSTALL: Installer could not run successfully if logged in as a Domain Administrator.
  • 128573 MODEL: Modeling particular dormer structure from Multi roof elements left incorrect roof intersections.
  • 158077 MODEL: A tube Morph wasn't solid if the beginning and ending faces overlapped.
  • 159509 MODEL: Fit to skin function didn't work with Shell tool.
  • 160134 MODEL: Vectorial hatching alignment could be wrong on particular Multiplane Roofs.
  • 160409 MODEL: 2D intersection of curved profiled walls might have been dependent on the zoom level.
  • 159241 SPEED: Zone schedule calculations could be slow in certain cases.
  • 159753 SPEED: Drawing Manager check status updates are now faster.
  • 161089 SPEED: Hidden Edges could cause freeze in certain 3D Document views.
  • 145636 TEAMWORK: common reason for "Internal Error" during open/join of a Teamwork project was corrected.
  • 157423 TEAMWORK: A Server Returns Error Code error occurred occasionally when a solid element operation was performed on a hotlinked wall.
  • 157434 TEAMWORK: Teamworked hotlinks with dimensions that were broken could result in Server Returns Error Code problems.
  • 158474 TEAMWORK: Autoupdate drawing data under certain circumstance was incorrectly sent to the server.
  • 159342 TEAMWORK: Creating a new element and giving it the name of a once-existing but since-deleted element then might cause the new element to be automatically deleted.
  • 159656 TEAMWORK: Embedded library textures and surfaces settings were not handled in all circumstances correctly inside of Teamwork.
  • 160285 TEAMWORK: The shell scripts of BIM Server could not run properly after installing Java update 1.6.0_51 on OS X. This resulted in unnecessary icons on the dock titled 'bin'.
  • 161173 TEAMWORK: The BIM Server could stop after a client side Send & Receive error.
  • 159577 TEAMWORK/HOTLINK: Hotlink data handling in Teamwork could be confused in certain conditions by simultaneous receives from two or more users. A new dialog warns users,when the conditions arise, that they must retry the receive command.
  • 159147 TEAMWORK/SPEED: Joining into very large Teamwork projects with many linked Hotlink Modules could be slow due to processing the embedded libraries of the Hotlink Modules.
  • 158771 VIEW: Projected display of Corner Windows were wrong in PBC mode in particular cases.
  • 159266 VIEW: Zooming in 3D window in Object Mode worked in the wrong direction with 3Dconnexion Mouse.
  • 160194 VIEW: Partial Structure Display error could occur in 3D Floor Plan Document views when Trace was used.
  • 161571 VIEW: Label Renovation status behaved different depending on the display order.
  • 161657 VIEW: Curved Composite Walls weren't visible on a Reflected Ceiling Plan 3D Document in the Legacy Intersection method.
  • 159159 VIEW (JPN): Japanese plan standards require attaching simplified plans and sections to the final set at 1/100, 1/200. At that scale, only the contours of the building components need to be visible. Overriding cut fills is the best solution, yet the override was partial on plans in AC17.
  • Bugs fixed in optional GRAPHISOFT components:
  • 158090 BIMx: On Windows activating the Crouch function caused the BIMx window to become inactive until clicking beside the BIMx window or pressing a key.
  • 159051 BIMx: Elements cut by a Cutplane with the "Use Element Attributes" setting in the "Cut Elements in 3D" dialog were flickering during BIMx navigation.
  • 159442 BIMx: BIMx file saved from ArchiCAD 17 could open with version of BIMx Viewer 16.
  • 159659 BIMx: Erroneous setting option for Lightmap quality is now removed from interface.
  • 159706 BIMX: Overwriting a .BIMx file while saving it resulted in its disappearance.
  • 160159 BIMx: BIMx file saved with the "Create Single Movie..." option from an ArchiCAD project containing multiple camera paths could cause BIMx crash.
  • 161182 BIMx: The rotation value of a texture in BIMx was one hundredth of the same value in ArchiCAD.

New in ArchiCAD 17 (Jul 20, 2013)

  • Modelling:
  • Link Element Heights to Stories, Adjust Walls to Slab Core
  • Core-Based Reference Planes for Walls and Slabs
  • Curved Beam
  • Anchor Door/Window Reveal to Wall Core
  • Priority-Based Junctions
  • Visualization / 3D Exploration:
  • Display Story Info on Guidelines
  • Easily Editable Real-Time 3D Cutting Planes
  • Documentation:
  • PDF/A Publishing Support for archiving
  • Export ArchiCAD Model to STL (Stereolithography) Format
  • Floor Plan-Based 3D Document
  • MORPH Listing 'by Story' for Conceptual Design / Mass Modeling
  • Integrated Connections with Google Earth, SketchUp
  • BIMx Available for All ArchiCAD Users
  • Productivity / Project Management / Performance:
  • Multiple Thermal Blocks, Building Systems, Operation Profiles
  • Building Materials incl. Surface, Priority, Thermal Property etc.
  • Background Processing Support, Optimization of Multi-core CPUs
  • Copy Any Element in Section and Elevation Views
  • Communication / Integrate with Engineering:
  • Support of IFC 2x3 Coordination View v2.0 (Export)
  • Support of IFC 2x3 Basic FM Handover MVD (COBie)
  • IFC Data: IFC System and IFC Time Series Schedule
  • Multilevel ('Sub') Hierarchy for IFC Assignments
  • Editable IFC Type Product Entities
  • Element Assignment to IFC Site or IFC Building
  • IFC Publishing Function
  • IFC:
  • Improved Options for Displaying Stairs and Railings
  • Enhanced Interface and Listing for RoofMaker
  • Door/Window Placement with Clear Feedback
  • Dimension Label Includes Element's Elevation Data
  • Teamwork / BIM Server:
  • BIM Project Backups to Restore BIM Server-related Data
  • PLN Format Backups to Quickly Recover Data in ArchiCAD

New in ArchiCAD 16 (Jan 8, 2013)

  • Morph Tool, Transform Existing Elements Into Morphs, Transform Morphs Into Objects, Free Graphical Editing of Morphs, Integrated Energy Evaluation, Automatic Model Geometry Analysis, Single Thermal Block Energy Model, Space Boundary Categories, Multiple Energy Model Visualization Options, Export Geometry in Excel Format, Export Second-Level Space Boundary Data via IFC, Extensive Built-in Building Material Lists, MEP System Lists, Green System and Energy Source Lists, Import Analytic Weather Data Files, Gridded Climate Information from the Online Weather Server, Quick Energy Evaluation Report, Certified VIPCore Engine Calculation, Improved Search Function for Finding Library Parts Faster in the Loaded, Embedded and BIM Server Libraries and on the Internet, BIM Components Portal, One Click Object Download and Embed, Drag & Drop Objects from the BIM Components Portal, Share Objects, Evaluate and Recommend Objects, All Model-Based Library Parts Can be Saved from the Floor Plan and 3D Window, Any Projection Can Be Used When Saving Library Parts from the 3D Window, Library Parts' Basic Attributes can be Defined When Saving Them, Input Elements Anywhere in 3D Space, Offset Editing Planes Before Placement, Place New Objects at Any Clicked Point, Snap to Surface in 3D Window, Move and Elevate in One Step, Lock Input to Editing Plane, Easier Access to Plane-switching Buttons,“Next Plane” Option, Zoom-sensitive Gridlines, New “Smart Cursor” Variants, Improved 3D Feedback for Split Command, Use Cutting Plane at Any Angle for Morphs, Split Morphs in Section View, Easy-to-use Rotate Command with Protractor Feedback, Merged Rotate and Free Rotate Commands in 3D, Better Project Location Definition, Define Project North Within the Building Model, Expanded Project Info Dialog Box, Expanded Teamwork Backup Options (BIM Project Backup, PLN Backup and Automatic Server Backup), Easy Recovery of Backups, Assign Thermal Properties to ArchiCAD Fills, Faster Hotlink Updates, Descriptions for All Library Parts, New Library Part Preview Pictures, New and Improved Objects Support for Office Design, New and Merged Lamp Types, Updated Plumbing Fixtures, New and Updated Building Structure Objects, Updated Railing Objects and People 2D Symbols, New Bollard Types, Simplified Taps, New Coordinate Object, New and Scale Sensitive Zone Stamp, Streamlined Label Options, Story Sensitive Display of Library Parts, New Door/Window Folder Structures and Names, Rationalization of Door and Window Objects, New Opening Types and UI for Special Windows, New Opening Types for Basic Windows, Variable Window Frame Widths, New Window Sash Type, Window Reveal Improvements, New Sliding Doors, New Sash Types for Door Sidelights, New Opening Types for Door Sidelight and Transom Sashes, New Handle Types, Pocket frame, Updated Storefront Doors, Door Casing with Roller Shutter, Use Find & Select on all IFC Properties, List IFC Properties in the Interactive Schedule, Display IFC Properties Just for Visible Elements, Import/Export Custom IFC Property Schemes, “One-Click” Custom IFC Property Assignment to All Elements, Quick IFC Property Editing, Support for Multiple IFC Standards, New IFC Assignments ("Space Occupant", "Actor"), IFC Classification Reference for Elements and Zones, Built-in and Custom Data Rules for Automated, Standard-Specific IFC Classification Reference Definition, IFC properties and Attributes Can Be Queried Through the ODBC Interface, IFC Properties and Attributes Can Be Extracted on the ArchiCAD API Interface, Filter Imported IFC Sites, Smarter Import of IFC Site Geometry, Better IFC Performance, Unchanged DWG Blocks Remain Intact Upon Roundtrip Conversion, Preserve Original DWG Block Positions, Smarter Handling of Zone Data when Exporting to DXF/DWG, Smart DWG Export of Rotated Views

New in ArchiCAD 15 (Sep 16, 2011)

  • Multi-Plane Roof, Revolved, Rotated and Ruled Shells, Enhanced Model Element Connections, Editing plane displayed during input, More sophisticated 3D feedback during selection and input, More informative feedback on coordinate axes in 3D window, 2D Guide Line Improvements, Brand new 3D guidelines, On-screen aids for precise placement/editing in 3D, Streamlined pet palette choices, Free Rotate in 3D, Improved Rotate in 2D, Streamlined element creation: Define element depth (z-value) graphically in 3D window, Element-level Definition of Renovation Status, Renovation Related Plan Types Out of the Box, Graphical Highlighting of Elements by Renovation Status, Simple Export of Different Plan Types, IFC Properties as Native ArchiCAD Parameters, More Accurate Assignment of IFC Parameters for Library Parts, More Powerful IFC Manager, Effective IFC Data Handling in Teamwork, Improved Localized Text Handling, New features of IFC import/export: IFC I/O Story-mapping, Improvements in Detect IFC Model Changes, Improved Merge to IFC function, Handling of Renovation status at IFC I/O, Easier library migration, New objects (Sustainable design, Medical usage, Furnishings, Sanitary objects), Door/Window enhancements, Native 64-bit Mac ArchiCAD, Faster Autosave, IFC Performance / Optimized export (performance) / Optimized import (performance).