What's new in IAW ECU Scan 0.2.29.18132 Beta
Aug 26, 2011
- Corrected a bug which was preventig program to refresh any data when ECU was not responding to one or more of the requests from the set.
New in IAW ECU Scan 0.2.28 Beta (Aug 26, 2011)
- Support for IAW-6F (Panda 1.0 FIRE FASE1)
- Removed [C]leared and [I]nterminnent error states
- Reduced CPU usage
New in IAW ECU Scan 0.2.27 Beta (Aug 26, 2011)
- Prolonged delay time after ADM to avoid generating random errors
- Improved Demo-Mode
- Corrected graphs scaling
New in IAW ECU Scan 0.2.26.41388 Beta (Jul 2, 2011)
- DEMO-Mode added
- Corrected TPS graph scalling
New in IAW ECU Scan 0.2.25 (Jul 2, 2011)
- Redesigned Active Test Set
- Minor code optimizations
- Added support for ECOL. (w/o immobilizer) ECUs
New in IAW ECU Scan 0.2.24 (Jul 2, 2011)
- Sign of error decoding in IAW-8F/18F/18FD
- Added option to reconnect or close connection after 10 subsequent comm. errors
- Improved connection algorithm (no need to wait for ECU fully shuts down before first connection)
- Corrected error decoding in IAW-8F/18F/18FD
New in IAW ECU Scan 0.2.23 (Jul 2, 2011)
- Saving ERRORS log to file
- Live Data logging to a CSV file
- Throttle bar on a Gauges screen
New in IAW ECU Scan 0.2.22 (Jul 2, 2011)
- Support for IAW-18FD (Punto 86 - 1.2 16V)
New in IAW ECU Scan 0.2.21.35599 (Apr 28, 2011)
- Injection duration time scalling corrected
- Polish translation was not completed... graph selection lists translated
New in IAW ECU Scan 0.2.20 (Apr 28, 2011)
- Major CPU usage reduction
- Polish translation is now complete
New in IAW ECU Scan 0.2.19 (Apr 28, 2011)
- Improved port selection storing method
- Complete GUI and partial Strings translation to Polish (UI language depends on a OS Locale settings)
New in IAW ECU Scan 0.2.18 (Apr 28, 2011)
- Stability improved on some problematic hardware
- Now errors are acquired only once per 5 queries (LD, STAT, LD, STAT, LD, STAT, LD, STAT, LD, STAT, ERR, LD, STAT, ...)
New in IAW ECU Scan 0.2.17 (Apr 28, 2011)
- Window scaling now possible
- Further performance improvement (32 Bps -> 46 Bps)
New in IAW ECU Scan 0.2.16.27134 (Apr 18, 2011)
- Added error group (Input, Output, Functional, CODE) and number
- Restored compatibility with .NET 2.0
- Major code reorganisation
- New labels for some parameters
- Slightly improved performance (29 sammple/sec -> 32 sample/sec)
New in IAW ECU Scan 0.2.15 (Apr 18, 2011)
- Introduction of 3rd error state in IAW-8F - (CUNEEPx)
New in IAW ECU Scan 0.2.14 (Apr 18, 2011)
- Resolved issue with application crash after Test timeout
New in IAW ECU Scan 0.2.13 (Apr 18, 2011)
- Error decoding now works again
- More error states, presented in more convinient way
New in IAW ECU Scan 0.2.12 (Apr 18, 2011)
- Change MAP units from mmHg to hPa (mBar)
- Upgrade to .NET Framework 3.5
New in IAW ECU Scan 0.2.11 (Apr 18, 2011)
New in IAW ECU Scan 0.2.10 (Apr 18, 2011)
- Corrected Status Flags decoding for IAW-8F/18F
New in IAW ECU Scan 0.2.9 (Apr 18, 2011)
- Added Gauges Panel (upon request)
- Minor code changes
New in IAW ECU Scan 0.2.8.35584 (Apr 6, 2011)
- Code optimizations and bug fixes
New in IAW ECU Scan 0.2.7 (Apr 6, 2011)
- KKL interface working again - fixed broken code
New in IAW ECU Scan 0.2.6 (Apr 6, 2011)
- Improved stability with KKL Interface
New in IAW ECU Scan 0.2.5 (Apr 6, 2011)
- Added Active Component Tests for IAW-x8F
- Timing routines rewritten
- Spare Part Code request codes moved from passive requests pool to init diag
- Language corrections
New in IAW ECU Scan 0.2.4 (Apr 6, 2011)
- Added test timeout
- Code optimizations and corrections
New in IAW ECU Scan 0.2.3 (Apr 6, 2011)
- Added Basic Errors Reading and Decoding from IAW-x8F
New in IAW ECU Scan 0.2.2 (Apr 6, 2011)
- Modification allowing to force connect when ECU Type is manually selected (no need to wait for Power Latch goes off before first connection)
New in IAW ECU Scan 0.2.1 (Apr 6, 2011)
- Added partial IAW-8F/18F Support (Live Data, System Status, FIAT CODE Errors, Error Cancellation)
- Minor code corrections and optimizations
New in IAW ECU Scan 0.2.0 (Apr 6, 2011)
- Added support for VAG-COM KKL USB interface (actually it was introduced in 0.1.3)
New in IAW ECU Scan 0.1.3 (Apr 6, 2011)
- Added adaptation parameters preview
New in IAW ECU Scan 0.1.2 (Apr 6, 2011)
- Added remaining IAW-16F parameters decoding (not all are displayed) and tests
- Minor UI changes
New in IAW ECU Scan 0.1.1 (Apr 6, 2011)
- Added ECU auto-detection routines (IAW-8F still not implemented, but auto-detects)
- Optimizations in communication protocol
New in IAW ECU Scan 0.1.0 (Apr 6, 2011)
- Added Active Components Tests
- Changed project status to BETA
New in IAW ECU Scan 0.0.17 (Apr 6, 2011)
- Added Vehicle Identification routines
- Code modifications to allow switching between IAW-16F and IAW-8F (not yet implemented)
New in IAW ECU Scan 0.0.16 (Apr 6, 2011)
- Stability improvements in the new communication routines
New in IAW ECU Scan 0.0.15 (Apr 6, 2011)
- Serial communication code rewriten from Event Based to Background Polling
New in IAW ECU Scan 0.0.14 (Apr 6, 2011)
- Added the Clear Error Codes feature (might be buggy)
- Fixed crash while disconnecting
New in IAW ECU Scan 0.0.13 (Apr 6, 2011)
- Added Status Byte Decoding and Visualisation
- Added CODE Errors Decoding
New in IAW ECU Scan 0.0.12 (Apr 6, 2011)
- Correction in temperature graphs scaling
- Corrected label - displayed data correlation in Graphs panel
- Corrected engine RPM decoding
- Corrected Error status descriptions ([I]nterminnent -> [A]ctive)
New in IAW ECU Scan 0.0.10 (Apr 6, 2011)
- IAW 8F Live Data decoding
New in IAW ECU Scan 0.0.9 (Apr 6, 2011)
- Graphs on Graph Panel should be working since now
- Tooltips added
New in IAW ECU Scan 0.0.8 (Apr 6, 2011)
- Added COM Port selection
- Added Graph Panel (not functional yet)
- Added COM Port State Check before Read/Write
- Added About Box
- Changed Menu Bar - new items: Select COM, Graph Refresh, About...
New in IAW ECU Scan 0.0.7 (Apr 6, 2011)
- Corrected graph scaling
- Corrected ESC Accelerator Key unbinding after succesful connection