What's new in OsciViewer 1.30.1.0
Sep 1, 2020
- Bugs:
- Serial for LeCroy functional again
- "Rescan" also works for serial interfaces
- Control buttons were not always selectable
New in OsciViewer 1.30.1.0 (Dec 25, 2018)
- Bugs:
- - Serielle für LeCroy wieder funktionsfähig
- - "Rescan" funktioniert auch für serielle Schnittstellen
- - Bedienbuttons waren nicht immer selektierbar
New in OsciViewer 1.30.0.0 (May 8, 2017)
- HP8620, no frequency was sent when the left table entry was 0
- Rescan implemented for GPIB devices; The entry is selected if Device is not online
- Timeout corrected for GPIB device
- New device HP3488 implemented
- Java Help implemented
- Settings file in HP8620.INI renamed
New in OsciViewer 1.29.1.0 (Mar 23, 2017)
- Released on 2016.12.30
- Bugs:
- TR4131: Querying the data from main window no longer collides with settings via ControlView window
New in OsciViewer 1.29.0.0 (Mar 23, 2017)
- Released on 2016.12.26
- Bugs:
- EMC scan probably no longer worked as of 1.27.0.0
- EMC analyzer: the reference level and the Y-unit have not been taken into account
- DIN standard probably no longer worked as of 1.27.0.0
- Crash when drivers other than GPIB were selected by NI: There were some missing methods
- New:
- A cyclic continuous query with storage can be activated
- EMC analyzer: Image of 3D view can be saved
New in OsciViewer 1.28.0.0 (Mar 23, 2017)
- Released on 2016.12.19
- Bugs:
- dB / div was not evaluated (was always 10); Scaling (8, 10 divs) was thus not adapted
- X axis was not output with enough decimal places
- Lecroy:
- Cursor was not always moving from the center
- Analyzer: Offset bits were not evaluated
- Changes:
- Title is centered in the image to be stored
- Checklist:
- Reference level is automatically read in at settings
- Current settings from the front panel are accepted
- dB / Div (10 dB, 2dB etc.) was not stored or read out in the settings
- Update check for SourceForge adapted (it must now be downloaded directly at SourceForge)
- no ClearDevice is triggered when scanning to devices or when opening the device; Front panel settings are retained (driver extended)
- New:
- Type of the device is output in the image to be saved
- additionally date / time can be output for the image to be saved
- TR4131:
- Y-axis is marked with a dash
- additional markers for 3 dB limit can be displayed
- HP8620:
- Sweep implemented
- Lecroy:
- Parameters for Min, Max, RMS and Frequency can be displayed additionally
New in OsciViewer 1.27.1.0 (Mar 23, 2017)
- Released on 2016.12.17
- New: A title for the image to be saved can be specified.
New in OsciViewer 1.27.0.0 (Mar 23, 2017)
- Released on 2016.12.14
- Remote / Local / Reset Buttons now work correctly
- GPIB driver corrected
- In the case of communication errors all further commands were nevertheless sent
- Checkview:
- Span 50 kHz was missing and Zerospan was wrong
- Time 20 sec was missing, thereby false 50 sec and 100 sec
New in OsciViewer 1.26.0.1 (Jun 3, 2014)
- Changes:
- File filters when saving the data is automatically set to "images"
- New:
- tray icon added
- Facilitates multi-monitor mode
- Soft keyboard for touch screen
New in OsciViewer 1.25.0.66 (Apr 30, 2014)
- Changes:
- Control buttons (finally removed globalization) only depends on the device
- EMC-board scan outsourced as a separate window
- Outsourced DIN standard limits as a separate window -
- Control for TR4131 rebuilt; mapped almost all the buttons 1:1
- New:
- window sizes are stored
New in OsciViewer 1.25.0.65 (Apr 30, 2014)
- Bugs:
- marker was displayed even though he was not activated
- Changes:
- marker is limited to 2 decimal places
- Negative frequency is included in the output unit
- Timeout of 100 msec to 400 msec increased
- TR4131: At a reception error without this header will again try to set
New in OsciViewer 1.25.0.42 (Apr 30, 2014)
- Bugs:
- version was not displayed when you call the jar file
- Increased timeout for OsciViewer.Exe to 30 seconds
- New:
- Control TR4131 View for:
- Button for signal track
- Press for standard
- Center Frequency is also displayed and stored
- Marker is displayed and stored
New in OsciViewer 1.25.0.6 (Apr 30, 2014)
- Bugs:
- Save the curve color works again
- OsciViewer did not start when driver was not installed for RXTX (serial interface)
- OsciViewer did not start when driver was not installed for LIBUSB (for the USB-GPIB adapter)
- OsciViewer did not start when drivers for NI card (eg NI PCI card) was not installed
- TR4131 : Error handling improved when receiving the Trace / write data
- Image preview when you save did not work, if there are spaces in the file name were present
- Changes:
- Reference Level is read with the other units ( dBm , dBu )
- Curve colors for each device type
- PM3311 is no longer supported ( use an old version if necessary)
- HP8620 is released locally again when the control window is closed
- New: Update check installed
- Implemented EMC board scan for the TR4131
- EMC board scan analyzer implemented
- Implemented SurfacePlot for EMC Board -
- Check for TR4131 : Date Units ( affects Reference Level )
- - Limits of DIN standards can be displayed
- Rewritten driver for handling serial communication -
- Integrated drivers for USB-GPIB converter from Elektor_2011_04
New in OsciViewer 1.24.0.0 (Apr 30, 2014)
- Bugs:
- language dissembled after calling the Kontrolls for TR4131
- Fixed problems with USBGPIB WIN32 (JNA gets any wrong pointer of LIBUSB)
- Changes:
- adapted German texts
- Natives for GPIB moved back to http://jpib.cvs.sourceforge.net/viewvc/jpib/jpib_2/NativeCode/
- Libraries (JPIB and JUSBPIB) outsourced as a JAR. Sources may be obtained separately from the respective projects on SourceForge
New in OsciViewer 1.23 (Apr 30, 2014)
- Repeat command an error is received when TR4131
- Lecroy: scaling and offset of MC and MD are shown correctly and displayed values
- Control window for TR4131 implements (with user settings in the "Settings")
- Ini files are stored in a sorted Control window for HP8621 implemented (settings in the "Settings")
- GPIB Scan Devices without automatic search with * IDN? This faster program start.
New in OsciViewer 1.22a (Apr 30, 2014)
- Unit labeling for X / Y axis were reversed
New in OsciViewer 1.22 (Apr 30, 2014)
- Integration of GPIB-PCI card (Windows 32/64bit)
- Additional Device: Advantest TR4131
- Data is stored with comma as decimal point (better for OpenOffice and Excel)
- Multilingualism
- Installer for Windows / Linux
- Internal corrections for offset, area requirements,
- Data length selectable for Lecroy
- COM port has been taken not always right
- Added some tooltips
- Limitation of image storage on 2500 points (otherwise makes the limp heap)
New in OsciViewer 1.21a (Apr 30, 2014)
- Integration of new serial driver (Windows / Linux 32/64 Bit)