What's new in PerfectLum 3.6.105
Jul 5, 2013
- Acceptance Test:
- user-friendlier daily tests: 1 step daily tests now passed with 1 mouse click
- display warm up time after ambient light and/or illumination measurements reduced from 1 min to 20 seconds
- for 'manual acceptance test' sensor information is now saved and always shows last entered sensor data
- initial questions in DIN 6868-57 and DIN 6868-157 reorganized
- Calibration:
- Gamut calibration integrated
- uniformity calibration improved
- color calibration improved
- ICC profile creation improved
- History:
- Display report’ improved, more details and optimization added
- Tools:
- Display test patterns’ can be changed by arrow keys while viewing
- Hardware:
- Minolta CS200 sensor integrated
- JETI specbos 1001, 2001, 2101, 4001
- power management of older Dell displays corrected
New in PerfectLum 3.5 (Jul 5, 2013)
- QA:
- editing of QA tasks made possible (now it’s possible to reschedule QA constancy tasks)
- QA tests made user-friendlier and much easier to pass (combined daily constancy tests, reuse of last entered/selected data, no report for daily tasks)
- possibility to add comments (which will appear in reports) for failed steps implemented
- Calibration:
- white level calibration improved
- color calibration improved
- ICC profile creation improved
- GUI:
- lots of GUI fixes and improvements
- GUI of preferences improved (sensor information is now automatically detected)
- only supported functions of display are now shown in preferences
- user specified logos for reports: company logo can be added to be displayed in reports
- Hardware:
- Gossen sensor support added
- new DELL Ultrasharp line support added (internal calibration + uniformity)
- new Olorin displays support added
- DELL U3011 support improved
- support of some displays with non-standard DDC/CI packages added
- Matrox M series native support added
- NVIDIA native support improved
- History:
- display report improved
- display consistency graphs improved to show all displays in one window
- possibility to exclude reports from display report added (right-click with a mouse on any history entry)
- more statistics, reports and data sent to PerfectLum Remote server
- Other:
- hardware display switch off for more accurate ambient light measurements
- DDC/CI support enhanced
- overall stability of software improved
- stability of PerfectLum and “PerfectLum Helper” communication improved
- possibility to disable notifications for a task by choosing “Never” in the reminder added
New in PerfectLum 3.0.1221 (Jul 5, 2013)
- Calibration:
- Rec. 709 calibration type added
- mac calibration speed and quality improved
- Hardware support
- Matrox Xenia Pro support added
- Nvidia DDC/CI native support added
- ATI DDC/CI native support added
- i1 Display Pro sensor support added
- sensor support improved
- Other
- overall stability of software improved
New in PerfectLum 3.0.1110 (Jul 5, 2013)
- Calibration:
- color calibration quality improved
- calibration speed increased
- support of internal calibration for Dell U3011 added
- enhanced DDC/CI support for various displays
- black level calibration feature added (now it is possible to calibrate not only white but also black level of the display automatically)
- possibility to create displays ICC profiles (v4 profiles with 3D CLUT) added
- QA:
- new DIN 6868-157 regulation integrated
- help buttons for all regulations added (now visual tests are more understandable and easier to pass).
- History:
- improved reports and graphs quality
- improved history entries (now the titles correspond to selected calibration settings)
- GUI:
- more help buttons added to preferences
- lots of small fixes
- Tools:
- Gamut Viewer ( now profiles can be visually checked and compared)
- possibility to view calibration effect on a display test pattern added (now it is possible to view a test pattern with applied/removed calibration)