What's new in SAEAUT UNIVERSAL OPC Server 5.03.03

Jul 24, 2013
  • Configuring application:
  • Added manifest – related to correct working with UAC
  • Runtime application:
  • Changes related to using as SAEAUT SCADA Server
  • Installation:
  • Common installation file for x86 an x64 OS platforms
  • Common installation script for more products
  • Improvements related to working with UAC

New in SAEAUT UNIVERSAL OPC Server 5.01.08 (Mar 22, 2013)

  • Updated documentation
  • Added OPC AE interface
  • New installation packages for:
  • OPC UA wrapper
  • OPCX XML DA wrapper

New in SAEAUT UNIVERSAL OPC Server 5.01.06 (Feb 21, 2013)

  • Configuring application:
  • Monitoring view enables not only reading but also writing of the OPC items
  • New enhanced trigger functionality and new configuring dialog box
  • New dialog box for events
  • New dialog box for commands
  • New dialog for the Sync.Controler features
  • New configuration structure (some elements as e.g. triggers cannot be automatically updated from older configurations but can be updated by hand.)
  • Output view is opened in individual window – to be able to watch log files in on line mode better. The Checker view and Find view are still in the main window
  • New dialog box for memory operands – settings for „Memory size and „Peersist data“ have been moved there from the dialog box for Sync.Controler
  • Interconnecting of OPC Item with Memory operand using common ID enables easier changes in configuration
  • Commands within tree view of the function block are numberred and ordered according to the command Nr.
  • New configuration database is created with structured folder for system variables in the address space of the internal OPC server to gain better overview
  • Runtime application:
  • Better keeping of the synchronous controller period
  • Improved trigger functionality
  • Improved performance – reduced time for executing of some commands
  • Better cooperation of the runtime core with enhancing dll’s
  • Asynchronous logging – reduced impact on the synchronous controller period
  • Examples:
  • Enhancing Dll examples:
  • There are two functionally identical example projects for the enhancing Dll for MS Visual Studio 2005 and MS Visual Studio 2005. They enable testing of functionality implemented within function DoProcessIO and called configurable command CALL DLL and in the same time testing of functionality of coordinating runtime and enhancing dll over commonly used memory operands.
  • Configurations:
  • Common - ExampleConfiguration.ODG – if DDE functionality is not installed this configuration is opened by the first start
  • For DDE client for OpcDbGateway and SAEAUT UNIVERSAL OPC Server:
  • DDETestBook.ODG – it enables test the DDE functionality
  • SystemToExcel.ODG – it enables (if DDE functionality is installed this configuration is opened by the first start )
  • XLS files – they are used for testing of the DDE client functionality
  • OPC_Server.xls – used with SystemToExcel.ODG
  • DDETestBook.xlsx - used with DDETestBook.ODG
  • START menu:
  • Added instalation and browsing for XML DA wrapper
  • Added instalation for OPC UA wrapper
  • Access to the online help was added to start menu of the application

New in SAEAUT UNIVERSAL OPC Server 4.01.00 (Jan 11, 2013)

  • Asynchronous logging to improve performance and keeping period of the sysnchronous conroller

New in SAEAUT UNIVERSAL OPC Server 4.00.00 (Jan 11, 2013)

  • OpcDbGateway can run also as Windows service
  • Added DDEclient functionality with easy and advanced configuring

New in SAEAUT UNIVERSAL OPC Server 3.17.00 (Jan 11, 2013)

  • SAEAUT UNIVERSAL OPC server can now run on the same computer with OpcDbGateway
  • Added On/Off switch possibility to display properties by browsing address space

New in SAEAUT UNIVERSAL OPC Server 3.16.01 (Jan 11, 2013)

  • Brings enhanced checker functionality into OpcDbGateway Configurator.