What's new in VIRTINS Multi-Instrument 3.9.8.1

May 8, 2023
  • Added modulation domain analysis in the functions from Freuqnecy Counter to Pulse Width in Multimeter. Frequency/RPM deviation (or Jitter) Peak (%), Max. Negative(%), Max. Positive (%) and Normalized Standard Deviation (%) are stored in DDPs: WowAndFlutter(%), WowRMS(%), FlutterRMS(%), WowAndFlutterRMS(%) respectively when Wow and Flutter option in [Spectrum Analyzer Processing] is not selected.
  • Added Frequency Time Curve (Timed) in DDC.
  • Added RPM Time Curve in DDC.
  • Added support for SI prefixes y, z, a, f and T, P, E, Z, Y additionally.
  • Support high-sensitivity USB digital charge amplifier VT CAMP-2G05A & VT CAMP-2G05B.
  • Support Earthworks microphone calibration files.
  • Added [Setting]>[Display]>ADC synchronized start/stop among multiple instances.
  • Added [Setting]>[Display]>DAC synchronized start/stop among multiple instances.
  • Added 32-bit float wave file support.

New in VIRTINS Multi-Instrument 3.9.7.0 (Nov 23, 2022)

  • Added support for RME ADI-2/4 PRO SE
  • Added support for RTA-168D
  • Added Articulation Index and Open Articulation Index and the corresponding DDPs: ArticulationIndex_A(%), OpenArticulationIndex_A(%), ArticulationIndex_B(%), and OpenArticulationIndex_B(%) in Sound Quality measurement in Spectrum Analyzer.
  • The functions: IFGT, IFGE, IFLT, IFLE, IFEQ, IFNE, IFIN that are used in UDDP definition now support text output in addition to number output.
  • Added tooltip to display the currently used DAC in the tilte bar of Signal Generator
  • Added [Help]>[Check for Software Updates]
  • Added [Setting]>[Display]>"Check for Software Updates on Startup
  • Increased the speed of [File]>[Open Frame by Frame]>"Frame Auto Scroll" function.
  • Added device filter options in [Setting]>[Restore to Factory Default].
  • Added Seting/Reseting MainframeStickyMoveFlag in Automation API
  • Added CopyToClipboard function in Automation API.
  • Added [Setting]>[ADC Device]>"Control Panel" button.
  • Added [Setting]>[DAC Device]>"Control Panel" button.
  • Added support for USA-168A and USA-168B.

New in VIRTINS Multi-Instrument 3.9.6.2 (Jul 19, 2022)

  • Added Shock Response Spectrum in DDC.

New in VIRTINS Multi-Instrument 3.9.6.1 (Jun 22, 2022)

  • Support 32-bit WAV files, ADC and DAC devices.
  • Added [Oscilloscope Reference]>"X Offset" and "Y Offset".
  • Additionally "Align to Peak" and "Align to Trough" options are
  • provided for X Offset for automatic alignment to the waveform
  • captured.
  • Added [Spectrum Analyzer Reference]>"Y Offset".
  • Maximum number of DDP Viewers increased from 16 to 24.
  • Added AckDDPAlarm() in ActiveX Automation API to acknowledge
  • DDP alarms.

New in VIRTINS Multi-Instrument 3.9.6.0 (May 23, 2022)

  • Added [Setting]>[Display]>"Record Mode">"No Auto Stop" option so that data will be recorded continuously into a sequence of files with file names being the time stamps.
  • Added [Oscilloscope Processing]>"Parameter Measurement">"Damping Ratio" and the corresponding DDPs: DampingRatio_A, DampingRatio_B.
  • Added [Oscilloscope Processing]>"Parameter Measurement">"Echo" and the corresponding DDPs: EchoTime_A(s), EchoTime_B(s).

New in VIRTINS Multi-Instrument 3.9.5.0 (Feb 21, 2022)

  • The second highest peak of Auto Correlation and the highest peak of Cross Corrleation are now detected based on the absolute values of correlation coefficient instead of the positive ones.
  • Fully support multiple Digiducer 333D01 with multiple software instances.
  • Added [Data Logger Chart Options]>"Title".
  • Added [Data Logger X Scale]>"Display Relative Time" option.
  • For the file opened via [File]>[Open Frame by Frame], it is possible to save the current frame as an individual WAV file or save the entire file as another WAV file.
  • Added [Setting]>[Display]>"Theme" selection box to provide visual style options for the software. Users will also be prompted with these options during the very first-time launch of the software after installation.
  • Added Dolph-Chebyshev 80, 100, 150, 200, 250 window functions.
  • Added Amplitude Spectral Density function in Spectrum Analyzer.
  • It can be selected via [Spectrum Analyzer Y Scale]>"Vrms"> "Energy Per Hz"
  • Added [Spectrum Analyzer Y Scale]>"dBr">"Vr@Hz" option in Spectrum Analyzer to allow setting the dBr reference level at a particular frequency.
  • Added [Spectrum Analyzer Y Scale]>"Gain Scale">"Linear" option in Transfer Function mode of Spectrum Analyzer.
  • Added SetUDDP() in ActiveX automation server API to allow an external automation client program to set a UDDP value.
  • Allow phase measurement even with inter-frame processing / intra-frame average / zero padding.
  • Added "Crest Factor Preview" button in Multitones Configuration Dialog. Added "Phase Optimization" button for manual configuration mode. Added three phase options for auto configuration mode: Randomized, Optimized 1 and Optimized 2.
  • Wow & Flutter measurement now supports a record of more than 2M samples.
  • Support gain switching seamlessly for RME ADI-2 Pro FS.
  • Added support for Digiducer 333D02, 333D04, MB63, 633A01, 485B39, SDC011.

New in VIRTINS Multi-Instrument 3.9.4.0 (Feb 15, 2021)

  • Added [DDP Viewer Configuration]>"Inter-frame Processing">"Max" and "Min" options.
  • [File]>[Import] now supports TXT files that contain only one or two columns of samples without header information.
  • Allow opening a WAV file, a properly formatted TXT file, or a TXT file contains only one or two columns of samples through drag and drop.
  • Allow [Setting]>[Display]>"Font Size" to be greater than 100%.
  • Added [Oscilloscope Processing]>"Digital Filtering">"Across Frames" option.
  • Added math functions ASIN, ACOS, ATAN in UDDP definition.
  • Added [Spectrum Analyzer Processing]>"Generalized Cross Correlation" option.
  • Support Persistence mode in Lissajous Plot.
  • Replace "dBB" with "dBZ" in Multimeter Type selection box. "dBA", "dBZ" and "dBC" in Multimeter and their respective DDPs are sharply bandlimited to 10Hz ~ 20kHz.
  • Added DDPs for Step Response Peak Time, Peak Settling Time, Trough Time, Trough Settling Time

New in VIRTINS Multi-Instrument 3.9.1 Build 2 (Jun 29, 2020)

  • Added X-Y Plot in Derived Data Curve list.
  • Added "Same Across Channels" option in Signal Generator. If ticked, identical white noises or pink noises can be generated in all channels.
  • Added Switch Positions 4~16 and the corresponding attenuation factors and aliases in [Setting]>[Calibration].The configuration of these parameters helps to scale the sampled data properly if the ADC device have gain or attenuation switches not controllable from Multi-Instrument.
  • Added Save Calibration File and Load Calibration File buttons in [Setting]>[Calibration] to facilitate the management of calibration files for multiple ADC devices.
  • Added x2000, x5000, x10000, x20000, x50000, x100000 options for Oscilloscope and Spectrum Analyzer horizontal axis multipliers.
  • [+] Added "f1(Hz)" options in [Spectrum Analyzer Processing]>"Parameter Measurement">"THD" and "Harmonics" to allow two additional fundamental frequency determination methods: User Defined and DDP Defined. This is in addition to the Peak Defined method. The User Defined method can be used when certain harmonics are stronger than the fundamental. The DDP Defined method can be used in applications such as order tracking.
  • Added "Original Frequency Response File (*.txt)" options in [Spectrum Analyzer Processing]> "Compensation 1" and "Compensation 2" to allow directly using those frequency response files provided by, for example, microphone manufacturers, without converting them to frequency compensation file (*.fcf) first.

New in VIRTINS Multi-Instrument 3.9 Build 2 (Jun 28, 2020)

  • Added X-Y Plot in Derived Data Curve list.
  • Added "Same Across Channels" option in Signal Generator. If ticked, identical white noises or pink noises can be generated in all channels.
  • Added Switch Positions 4~16 and the corresponding attenuation factors and aliases in [Setting]>[Calibration].The configuration of these parameters helps to scale the sampled data properly if the ADC device have gain or attenuation switches not controllable from Multi-Instrument.
  • Added Save Calibration File and Load Calibration File buttons in [Setting]>[Calibration] to facilitate the management of calibration files for multiple ADC devices.
  • Added x2000, x5000, x10000, x20000, x50000, x100000 options for Oscilloscope and Spectrum Analyzer horizontal axis multipliers.
  • Added "f1(Hz)" options in [Spectrum Analyzer Processing]>"Parameter Measurement">"THD" and "Harmonics" to allow two additional fundamental frequency determination methods: User Defined and DDP Defined. This is in addition to the Peak Defined method. The User Defined method can be used when certain harmonics are stronger than the fundamental. The DDP Defined method can be used in applications such as order tracking.
  • Added "Original Frequency Response File (*.txt)" options in [Spectrum Analyzer Processing]> "Compensation 1" and "Compensation 2" to allow directly using those frequency response files provided by, for example, microphone manufacturers, without converting them to frequency compensation file (*.fcf) first.

New in VIRTINS Multi-Instrument 3.8 Build 5 (Dec 31, 2018)

  • Added Frame Width dialog box for [File]>[Open Frame By Frame] so that users can specify the frame width explicitly.
  • Added [Display Ch. A only], [Display Ch. B only] and [Display All] commands in the context menus of Oscilloscope, Spectrum Analyzer and Spectrum 3D Plot.
  • Added variable support for Instructions SIR and SOR in Device

New in VIRTINS Multi-Instrument 3.8 Build 2 (May 28, 2018)

  • Added a DDP Array Viewer to view an DDP array or a combination of DDP arrays. It can be launched from the existing DDP Viewer Configuration dialog box.
  • Added six DDP arrays: fnFreq_A(Hz)_Array[?], fnRMS_A(EU)_Array[?], fnPhase_A(EU)_Array[?],fnFreq_B(Hz)_Array[?], fnRMS_B(EU)_Array[?], fnPhase_B(EU)_Array[?] for frequencies, amplitudes and phases in Ch.A and Ch.B respectively.
  • Added phase measurement for the 2nd~100th orders in "Harmonics" measurement and "Peaks" detection in Spectrum Analyzer Processing. This is in addition to the existing phase measurement for the fundamental.
  • Added amplitude measurement for the 8th~100th orders in "Harmonics" measurement and "Peaks" detection in Spectrum Analyzer Processing. This is in addition to the existing amplitude measurement for the 1st~7th order of harmonics or peaks.
  • Added amplitude measurement for the 9th~100th frequency bands in "Energy in user defined frequency bands" in Spectrum Analyzer Processing. This is in addition to the existing amplitude measurement for 1st~8th frequency bands.
  • Added "Gm" (GedLee metric) option in Spectrum Analyzer Processing. It is an auditory-perception-weighted measure of nonlinear distortion. The calculated Gm value can be accessed through the newly added DDPs: GedLeeMetric_A for Ch.A and GedLeeMetric_B for Ch.B.
  • Added "Time Delay Removal" option in Oscilloscope Processing to remove the time delay, if any, between the two channels and make the measured data in the two channels time aligned.
  • Added "Line Width on Printer" option in [Setting]> [Display Setting].
  • A Panel Setting File can be encrypted and protected as an intellectual property. A protected panel setting file can only be used in customized MI applications when the panel setting is locked via [Help]>[Lock Panel Setting].
  • The maximum number of sound card ASIO input or output channels out of which the Ch.A and Ch.B can be selected has been increased from 32 to 200.
  • Added 12 reports which can be viewed through DDP Array Viewer. They are:
  • Harmonic Frequencies, RMS, Phases for Ch.A, Ch.B or Both
  • Octave Bands, RMS for Ch.A, Ch.B or Both
  • Peak Frequencies, RMS, Phases for Ch.A, Ch.B or Both
  • Frequency Bands, RMS, Ch.A, Ch.B or Both
  • The data in the reports can be exported as a text file or copied as text into the clipboard. Reports (1) and (3) can also be exported as a Tone Configuration File which can be imported into Signal Generator to reconstruct the multitone signal.

New in VIRTINS Multi-Instrument 3.8 Build 1 (Mar 27, 2018)

  • Waveform type:
  • Unit Impulse and Unit Step in Signal Generator have their jumps shifted from t=0 to t=0.5s if signal duration >= 1s, or t=half of the signal duration if it is less than 1s, in order to allow the response of a non-causal filter to be shown.
  • Print function in Oscilloscope, Spectrum Analyzer, Spectrum 3D Plot, Data Logger, X-Y Plot of Device Test Plan will automatically invert the foreground color if it happens to be white when the screen background color is not white, as the background color of printing is fixed at white irrespective of the screen background color chosen. When the color of a channel is intentionally selected to be the same as the screen background color, the text and curve of that channel will be hidden on screen and printing.
  • Added additional zoom in/out methods in Oscilloscope, Spectrum Analyzer and Spectrum 3D Plot: 1) Mouse wheel forward: zoom in along X axis. 2) SHIFT + Mouse wheel forward: zoom in along A axis. 3) CTRL + Mouse wheel forward: zoom in along B axis. 4) Mouse wheel backward: zoom out along X axis. 5) SHIFT + Mouse wheel backward: zoom out along A axis. 6) CTRL + Mouse wheel backward: zoom out along B axis. Zooming in/out on a graph is sticky with regards to current position of the mouse cursor. 7) Mouse wheel down & scroll: return to default along X axis 8) SHIFT + Mouse wheel down & scroll: return to default along A axis 9) CTRL + Mouse wheel down & scroll: return to default along B axis
  • Added inter-frame processing including linear and exponential average in DDP viewer.
  • Added a new type of waveform library option - BitPerfect Library (*.bpl) in WFLibrary function in Signal Generator. J-Test signal for jitter test can be generated using this function. BitPerfect library examples such as J-Test_16Bit.bpl and J-Test_24Bit.bpl are provided under WFL subdirectory of the software.
  • Added Non-Coherence option in Spectrum Analyzer Processing, to allow the switching between coherence and non-coherence function display modes. A new DDP: TNCD_AB(%) for Total Non-Coherent Distortion and Noise is added. It will be calculated in Non Coherence Function display mode.
  • The maximum number of tones that can be manually configured in MultiTones in Signal Generator has been increased from 32 to 200.
  • Added automatic multitone configuration method in Signal Generator. Each frequency component can be aligned to the center frequency of each FFT bands or fractional octave bands, so as to uniformly activate all the frequency bands within the specified frequency range. Each frequency is added automatically at pseudo random initial phase to make the multitones noise-like.
  • Added gain and phase compensation option in Spectrum Analyzer Processing for transfer function measurement. This option can be used to compensate the gain and phase difference between the two input channels of the measuring device itself. The "Spectrum Analyzer Generate Frequency Compensation File (Flat)" option in the context menu of Spectrum Analyzer is enabled accordingly for Transfer Function mode.
  • Added "Convert to Impedance" and the related parameters in Spectrum Analyzer Y Scale to convert Amplitude Spectrum display to Impedance vs Frequency display using the single-channel method. The same set of parameters can also convert Gain and Phase plot to Impedance and Phase plot under Transfer Function mode using the dual-channel method. Speaker impedance measurement examples using various stimuli are introduced in the software manual, including an easy way to conduct impedance measurement using VT DSOs.
  • Extended the following DDPs' usage in impedance measurement: f1Freq, f1RMS, InBandMinF, InBandMinRMS, InBandMaxF, InBandMaxRMS, PeakGainFreq, PeakGainValue, PeakGainPhase, GainAtGeneratedFreq, PhaseAtGeneratedFreq, oBandRMS_Array.
  • Added Trigger Frequency Rejection options for vtDAQ compatible DLLs including SoundCardMMEDAQ.dll, SoundCardASIODAQO.dll and NIDAQ.dll. Sound cards and NI DAQmx cards using software triggering method now support 1 level of high frequency rejection, 5 levels of noise rejection and 6 levels of the combination of the two. This is to ensure stable triggering under all conditions.
  • Allow Trigger level to be entered manually for finer control.
  • ENTER key can be used to start/stop oscilloscope or signal generator under all conditions.
  • Allow simultaneous crosstalk measurement from Ch.A to Ch.B and from Ch.B to Ch.A using a little different test frequencies in the two channels.
  • Added "Duration (ms)" under [Setting]>[Display]>"Record Mode". The recording process will automatically stop if the specified duration is reached. This is in addition to the existing manual stop mechanism and the automatic stop mechanism when the maximum file size limit is reached. If the duration is set to zero, the recording process will also automatically stop when the maximum file size limit is reached.

New in VIRTINS Multi-Instrument 3.8 (Mar 22, 2018)

  • Waveform type: Unit Impulse and Unit Step in Signal Generator have their jumps shifted from t=0 to t=0.5s if signal duration >= 1s, or t=half of the signal duration if it is less than 1s, in order to allow the response of a non-causal filter to be shown.
  • Print function in Oscilloscope, Spectrum Analyzer, Spectrum 3D Plot, Data Logger, X-Y Plot of Device Test Plan will automatically invert the foreground color if it happens to be white when the screen background color is not white, as the background color of printing is fixed at white irrespective of the screen background color chosen. When the color of a channel is intentionally selected to be the same as the screen background color, the text and curve of that channel will be hidden on screen and printing.
  • Added additional zoom in/out methods in Oscilloscope, Spectrum Analyzer and Spectrum 3D Plot
  • 1) Mouse wheel forward: zoom in along X axis.
  • 2) SHIFT + Mouse wheel forward: zoom in along A axis.
  • 3) CTRL + Mouse wheel forward: zoom in along B axis.
  • 4) Mouse wheel backward: zoom out along X axis.
  • 5) SHIFT + Mouse wheel backward: zoom out along A axis.
  • 6) CTRL + Mouse wheel backward: zoom out along B axis.
  • Zooming in/out on a graph is sticky with regards to current
  • position of the mouse cursor.
  • 7) Mouse wheel down & scroll: return to default along X axis
  • 8) SHIFT + Mouse wheel down & scroll: return to default along A axis
  • 9) CTRL + Mouse wheel down & scroll: return to default along B axis
  • Added inter-frame processing including linear and exponential average in DDP viewer.
  • Added a new type of waveform library option - BitPerfect Library (*.bpl) in WFLibrary function in Signal Generator. J-Test signal for jitter test can be generated using this function. BitPerfect library examples such as J-Test_16Bit.bpl and J-Test_24Bit.bpl are provided under WFL subdirectory of the software.
  • Added Non-Coherence option in Spectrum Analyzer Processing, to allow the switching between coherence and non-coherence function display modes. A new DDP: TNCD_AB(%) for Total Non-Coherent Distortion and Noise is added. It will be calculated in Non Coherence Function display mode.
  • The maximum number of tones that can be manually configured in MultiTones in Signal Generator has been increased from 32 to 200.
  • Added automatic multitone configuration method in Signal Generator. Each frequency component can be aligned to the center frequency of each FFT bands or fractional octave bands, so as to uniformly activate all the frequency bands within the specified frequency range. Each frequency is added automatically at pseudo random initial phase to make the multitones noise-like.
  • Added gain and phase compensation option in Spectrum Analyzer Processing for transfer function measurement. This option can be used to compensate the gain and phase difference between the two input channels of the measuring device itself. The "Spectrum Analyzer Generate Frequency Compensation File (Flat)" option in the context menu of Spectrum Analyzer is enabled accordingly for Transfer Function mode.
  • Added "Convert to Impedance" and the related parameters in Spectrum Analyzer Y Scale to convert Amplitude Spectrum display to Impedance vs Frequency display using the single-channel method. The same set of parameters can also convert Gain and Phase plot to Impedance and Phase plot under Transfer Function mode using the dual-channel method. Speaker impedance measurement examples using various stimuli are introduced in the software manual, including an easy way to conduct impedance measurement using VT DSOs.
  • Extended the following DDPs' usage in impedance measurement: f1Freq, f1RMS, InBandMinF, InBandMinRMS, InBandMaxF, InBandMaxRMS, PeakGainFreq, PeakGainValue, PeakGainPhase, GainAtGeneratedFreq, PhaseAtGeneratedFreq, oBandRMS_Array.
  • Added Trigger Frequency Rejection options for vtDAQ compatible DLLs including SoundCardMMEDAQ.dll, SoundCardASIODAQO.dll and NIDAQ.dll. Sound cards and NI DAQmx cards using software triggering method now support 1 level of high frequency rejection, 5 levels of noise rejection and 6 levels of the combination of the two. This is to ensure stable triggering under all conditions.
  • Allow Trigger level to be entered manually for finer control.
  • ENTER key can be used to start/stop oscilloscope or signal generator under all conditions.
  • Allow simultaneous crosstalk measurement from Ch.A to Ch.B and from Ch.B to Ch.A using a little different test frequencies in the two channels.

New in VIRTINS Multi-Instrument 3.7 (Jun 19, 2017)

  • [Window]>[Cascade],[Tile Horizontally] and [Tile Vertically] functions are improved.
  • "Auto layout after loading a Panel Setting File" option is added in [Setting]>[Display].
  • Add demodulation (AM, FM, PM) option in Oscilloscope Processing.
  • Add Remove DC and Half/Full Wave Rectification options in Oscilloscope Processing.
  • SINC interpolation, Remove DC, Rectification, Digital Filtering modes are indicated through their respective signs in Oscilloscope window.
  • The start and end points in [File]>[Extract] dialog can now be automatically filled with the positions of the two markers placed on the waveform to be extracted.
  • Add Sound Loudness and Loudness Level measurement in Spectrum Analyzer Processing. Both free field and diffuse field are supported.
  • Add Unweigted and weighted Wow & Flutter measurement in Spectrum Analyzer Processing.
  • Add Second Peak detection including the time delay and coeffient in auto-correlation function in Spectrum Analyzer.
  • Add output modulation (AM, FM, PM) option in Signal Generator.
  • Add [Help]>[Software Manual] menu item.
  • Update software manual to include more descriptions and make it easier to understand.
  • Output amplitude displayed in dBFS,dBu or dBV can be switched by clicking those texts in Signal Generator Panel.
  • All the processing names in Oscilloscope and Spectrum Analyzer processing pages are marked with a number according to their order of execution to help the users to understand the signal flow and design their own signal processing methods.

New in VIRTINS Multi-Instrument 3.3 Build 1 (Jul 11, 2013)

  • Added support for second-generation VT DSOs including all the advanced functions such as trigger frequency rejection in Oscilloscope, effective bit resolution enhancement in Oscilloscope, mixed signal display in Oscilloscope, DDS mode
  • in Signal Generator, DC offset in Signal Generator and Device Test Plan.
  • Added oscilloscope persistence and equivalent time sampling modes.
  • Peaks detected in Spectrum Analyzer can be sorted by either magnitude or frequency.
  • Added Number of Decimal Places in DDP viewer.
  • Added 16 User Definable Data Points (UDDP) in DDP viewer.
  • Sophisticated mathematical formula can be used to define a UDDP.
  • An example of a DTMF decoder in noisy environment is provided.
  • It is possible to log a time stamp in Device Test Plan Log.
  • Added non-overwrite mode for SIO and OUT instructions in Device Test Plan.
  • Added non-trigger mode for SIO and STI instructions in Device Test Plan.
  • Added a code example for vtDAQ intermediate interface DLL MyDAQ.dll) to allow MI interfaces to a third-party DAQ device.
  • Added peak-to-peak DDPs for A and B channels.
  • Added IIR coefficient files for moving average filters (2,4,8,16,32,64,128,256 points) in Oscilloscope.
  • Step execution clock in Device Test Plan is increased by 10 times. Added a sample device test plan for playing "Happy Birthday" music.
  • The displayed precision of a variable is based on its own source precision. The value is written in the form of xx.xx y, where y is G,M,k, ,m,u,n, or p, each of which represents a power of 1000. The displayed value will not move left and right as the value changes.
  • Modifying entries in Device Test Plan, ADC device database and DAC device database became easier.
  • The parameters for each channel in the toolbars are colored with the color specified for that channel.

New in VIRTINS Multi-Instrument 3.1 (Jan 10, 2009)

  • Added support for other ADC/DAC devices such as NI DAQmx device and VT DSO from Virtins Technology, in addition to sound cards.
  • Added support for sound card ASIO driver.
  • Added Smoothing via Moving Average as one of the Intra-Frame
  • processing method in Spectrum Analyzer.
  • Added Exponential Average as one of the Inter-Frame processing
  • method in Spectrum Analyzer
  • Added measurement of 1st~7th harmonics energy in Spectrum Analyzer. The phase of the 1st harmonics will also be measured.
  • Added measurement of energy contained in up to 8 user defined
  • frequency bands.
  • Added detection of up to 7 frequency peaks and measurement of
  • their energy.
  • Added 1/48 and 1/96 octave analysis in Spectrum Analyzer.

New in VIRTINS Multi-Instrument 3.0 (Jan 3, 2008)

  • New: Multi-Instrument
  • New: Multi-Instrument Pro
  • New add-on: Spectrum 3D Plot
  • New add-on: Data Logger
  • New add-on: LCR Meter
  • New add-on: Device Test Plan
  • Merged the softkey license and hardkey license
  • Added Multimeter, including RMS, dBV, dBu, dBSPL, dBA, dBB, dBC, Freq. Counter,RPM,Duty Cycle,F/V Meters
  • Added Spectrum 3D Plot, including Waterfall Plot and Spectrogram.
  • Added Data Logger.
  • Added LCR Meter.
  • Added Device Test Plan.
  • Added "Open Frame by Frame" command in the File menu to allow loading a long wave file.
  • Added "Import" command in the File menu to allow the import of text data.
  • Allow input & output sound card selection via the Calibration dialog.
  • Added "Reference" tab for all relevant views, to allow the display of reference curves.
  • Added "Line Width" in all relevant Chart Options pages.
  • Allow differential trigger in DAQ
  • Added sample files, settings, examples in the software package.
  • Added "Play" and "cyclic Play" buttons in the Miscellaneous Toolbar to allow direct replay of the waveform in Oscilloscope
  • Added various digital filtering methods in Oscilloscope.
  • Added time stamp and DAQ process indicator in Oscilloscope.
  • Added "Record" mode in Oscilloscope.
  • Added frequency compensation, frequency weighting A,B,C,ITU-R 468) in Spectrum Analyzer
  • Added Noise Level,IMD,Bandwidth,Crosstalk measurement in Spectrum Analyzer
  • Added Coherence, Gain & Phase (Bode Plot), Impulse Response modes in Spectrum Analyzer
  • Added "iA=oA, iB=oA", "iB=oA", "Sync. No Loopback", "Sync. iB=oA", "Sync.iB