SonicDICOM PACS Changelog

What's new in SonicDICOM PACS 3.13.1

Apr 17, 2024
  • Improvements:
  • On List page, it can display a finalized report by clicking/tapping the status "Final" of Study List.
  • On List page, it can display details of sharing information by clicking/tapping the status "Shared" of Study List.
  • On List page, it can cancel importing DICOM files.
  • On List page, it can cancel forwarding DICOM files.
  • On List page, Patient IDs before/after anonymization will be displayed after the DICOM files have been forwarded.
  • On List page, a PDF file can be added as a single-frame image when adding it to a series of a study.
  • It can set the label, ordering, and show/hide for the report fields: Admin Settings > Client > Report > Layout
  • The database will not be automatically switched to Microsoft SQL Server Compact when a connection to Microsoft SQL Server is not established successfully.
  • Entering Connector ID is no longer required when activating Cloud Connector (for SonicDICOM PACS Cloud only).
  • Bug fixes:
  • Fixed a bug that a searchbar on Viewer page is not displayed when thumbnailbar is positioned at the top.
  • Fixed a bug that sometimes thumbnails of series are not displayed (for SonicDICOM PACS Cloud only).
  • Fixed a bug that images are not overwritten if there is an image with the same UID when uploading new images (for SonicDICOM PACS Cloud only).
  • Fixed several other minor bugs.

New in SonicDICOM PACS 3.11.1 (Aug 29, 2023)

  • Improvements:
  • On List page, it can retrieve the information of patient list when importing DICOM file.
  • On List page, it can retrieve the information of patient list when importing JPEG/PNG/BMP/PDF file.
  • On List page, it has been changed that the current date and time are automatically entered in "Study Date" and "Study Time" when importing JPEG/PNG/BMP/PDF files.
  • User interface related to permissions for Role has been improved.
  • Various improvements related to Modality Worklist have been made.
  • Bug fixes:
  • Fixed a bug that %MA feature does not work properly.
  • Fixed a bug that a character set of Modality Worklist created by reading a CSV file is always "ISO 2022 IR 6".
  • Fixed several bugs related to Modality Worklist.
  • Fixed several other minor bugs.

New in SonicDICOM PACS 3.11.0 (Jun 9, 2023)

  • New feature:
  • Modality Worklist has been implemented (for SonicDICOM PACS only).
  • Improvement:
  • Target of Quick Search can be selected from select menu on List page.
  • Bug fixes:
  • Fixed a bug that an error occurs when selecting "Attach DICOM Viewer" in exporting DICOM file.
  • Fixed a bug that some DICOM files of JPEG Lossless format are not displayed correctly.
  • Fixed a bug that measurement results are not displayed correctly in some ultrasound multi-frame images.

New in SonicDICOM PACS 3.9.7 (Jul 28, 2022)

  • Improvements:
  • DICOM tag "Conversion Type (0008,0064)" is added when converting PDF/JPEG/PNG/BMP file to DICOM file.
  • Bug fixes:
  • Fixed a bug that the search results by Referring Physician Name is not correct on List page when the search is done by an account under viewing control.
  • Fixed a bug that an error occurs when sorting by Study Date on List page.
  • Fixed a bug that sometimes some DICOM files cannot be displayed properly.

New in SonicDICOM PACS 3.9.5 (Apr 15, 2022)

  • Improvements:
  • Google authentication is available to log in to PACS (for SonicDICOM PACS Cloud only).
  • The page displayed when a guest account fails to log in to PACS has been changed.
  • It can be switched to show/hide the input contents of the password field.
  • Sample DICOM files are available to be imported when there is no item on Study List.
  • The maximum file size limit for converted PDF file to DICOM file has been changed to 2,000,000,000 bytes (about 2 GB).
  • Bug fixes:
  • Fixed a bug that a dialog is not displayed that the number of web connections has already reached the limit when an item on Study List is selected.
  • Fixed a bug that Share feature does not work when the Account ID to be shared with is an email address.
  • Fixed a bug that some PDF files cannot be converted to a DICOM file properly.
  • Fixed a bug that sometimes DICOM files of JPEG 2000 Lossless format cannot be displayed properly.
  • Fixed a bug that sometimes RGB image of RLE format cannot be displayed properly.
  • Fixed a bug that Report Title is not displayed immediately after the Report is saved.
  • Fixed a bug that sometimes lines break in the middle of words in Report PDF.

New in SonicDICOM PACS 3.9.3 (Dec 27, 2021)

  • Improvements:
  • Email address is available as Account ID to log in to PACS
  • Bug fixes:
  • Fixed a bug that SonicDICOM PACS and PACS Manager do not start if the database is Microsoft SQL Server Compact.
  • Fixed a bug that it could not receive data from a specific Ultrasound device.
  • Fixed a bug that List page is not displayed properly when logged in as a guest.

New in SonicDICOM PACS 3.9.2 (Dec 20, 2021)

  • Bug fixes:
  • Fixed a bug that sometimes some items in the toolbar do not work properly.
  • Fixed an issue that some DICOM files compressed in JPEG 2000 Lossless format are not displayed correctly.

New in SonicDICOM PACS 3.9.0 (Sep 21, 2021)

  • New Feature:
  • Toolbar for Guest can be set: Admin Settings > Share > Guest
  • Improvements:
  • Ping and DICOM Echo is available in dialog "Add DICOM User" and "Edit DICOM User" (for SonicDICOM PACS only).
  • The loading time for the initial display of Viewer page has been accelerated.
  • Bug fixes:
  • Fixed a bug that "Back" button of the web browser does not return to the previous page.
  • Fixed a bug that Share feature is unavailable when the number of shared studies or patients exceeds a certain number.
  • Fixed a bug that multi-frame images of PALETTE COLOR cannot be displayed properly.
  • Fixed a bug that sometimes texts on the images cannot be displayed properly on Viewer page.

New in SonicDICOM PACS 3.8.0 (Jul 16, 2021)

  • New Feature:
  • %MA feature has been implemented: User Settings > Viewer > Toolbar
  • Improvements:
  • If DICOM file has a DICOM tag that indicates FPS value, the value is referred when playing Cine.
  • Bug fixes:
  • Fixed a bug that sometimes color images cannot be displayed properly.
  • Fixed a bug that sometimes the search results by Study Date is not correct on List page.
  • Fixed a bug that Study cannot be edited on List page if an unexpected value is entered for DICOM tag "Specific Character Sets".
  • Fixed a bug that sometimes touch operation does not work properly on Viewer page.

New in SonicDICOM PACS 3.7.9 (Jun 24, 2021)

  • Bug fixes:
  • Fixed a bug that sometimes the date could not be entered when the date format is "DD-MM-YYYY" or "DD/MM/YYYY".
  • Fixed a bug that sometimes period search does not work properly when the date format is "DD-MM-YYYY" or "DD/MM/YYYY".
  • Fixed a bug that sometimes SonicDICOM Media Viewer cannot display images properly.
  • Others:
  • License Agreement has been updated.
  • Data Processing Terms has been added.

New in SonicDICOM PACS 3.7.8 (Apr 14, 2021)

  • Improvements:
  • The resolution has been improved when importing PDF file in dialog "Import File" on List page.
  • Validation has been implemented in Findings, Impression and Comments on Report page.
  • Bug fixes:
  • Fixed a bug that some files were not backed up on Daily Backup of database.
  • Fixed a bug that setting of "First Day of Week" is not applied in dialog "Edit Share".
  • Fixed a bug that sometimes validation does not work correctly in dialog "Import File" on List page.
  • Fixed a bug that it fails to export PNG file when DICOM file is multi-frame in dialog "Export JPEG/PNG/BMP" on Viewer page.
  • Fixed several other minor bugs.

New in SonicDICOM PACS 3.7.7 (Mar 24, 2021)

  • Improvements:
  • It can set "First Day of Week" of calendar as Monday or Sunday: Admin Settings > General > Localization
  • Bug fixes:
  • Fixed a bug that Shortcut of "Share With" does not work correctly in a dialog "Share Study/Patient".
  • Fixed a bug that dialog "Edit Cloud Connector" is not displayed correctly.
  • Fixed a bug that sometimes validation does not work correctly in dialog "Add DICOM User" and "Edit DICOM User".
  • Fixed several other minor bugs.

New in SonicDICOM PACS 3.7.6 (Mar 11, 2021)

  • Improvements:
  • Each field can be initialized in Admin Settings and User Settings.
  • Match criteria of Note can be selected in dialog "Advanced Search" on List page.
  • Bug fixes:
  • Fixed a bug that sometimes information of "Shared With" is not displayed correctly.
  • Fixed a bug that Access Key is not displayed in dialog "Information of Share" when sharing with Guest.
  • Fixed a bug that "Institution" cannot be hidden in dialog "Advanced Search" on List page.

New in SonicDICOM PACS 3.7.5 (Mar 8, 2021)

  • Fixed a bug that the studies containing multi-frame images cannot be edited and deleted.

New in SonicDICOM PACS 3.7.4 (Mar 4, 2021)

  • Bug fixes:
  • Fixed a bug that receiving DICOM Query (C-Find SCP) does not work properly.

New in SonicDICOM PACS 3.7.3 (Mar 1, 2021)

  • New features:
  • VHS (Vertebral Heart Size) feature has been implemented: User Settings > Viewer > Toolbar.
  • Improvements:
  • "Institution" has been added to the criteria of permissions to access studies at level of Institution: Admin Settings > Account
  • Placed Cloud Connector, DICOM Provider and DICOM User under Institution: Admin Settings > Server > Connection
  • Changed the specification of the sort order of Study List so that sorting of Study Date and Time in descending order is automatically applied as necessary.
  • On Advanced Search, search of Institution and Note is available.
  • On Advanced Search, the selection method for Patient Sex and Report Status has been changed from select menu to checkbox.
  • Images of Digital Breast Tomosynthesis has been supported.
  • The speed of opening multi-frame images has been significantly accelerated.
  • Bug fixes:
  • Fixed a bug that users cannot log in from the login form when the ID is two characters.
  • Fixed a bug that temporary files are not deleted properly when backing up database files.

New in SonicDICOM PACS 3.7.2 (Jan 11, 2021)

  • New features:
  • Multi-Monitor feature has been implemented: Browser Settings > Multi-Monitor
  • Auto-Delete feature has been implemented: Admin Settings > Server > Auto-Delete
  • Password Strength for Accounts can be set : Admin Settings > General > Security
  • Login Block is available: Admin Settings > General > Security
  • On List page, exporting CSV file is available.
  • On List page and Viewer page, it can open Report PDF directly.
  • Improvements:
  • Deletion History can be available: Admin Settings > Server > Recycle Bin > Deletion
  • History
  • Maximum number of Concurrent Connections for Import can be set: User Settings >
  • List > General
  • "Body Part Examined" has been added to the criteria of control viewing Study at
  • Level of Institution/Role: Admin Settings > Account
  • Bug fixes:
  • Fixed a bug that sometimes Report PDF is not displayed properly.
  • Fixed a bug that sometimes changing Favicon does not work correctly: Admin Settings
  • General > Option
  • Others:
  • Bulgarian language has been supported.

New in SonicDICOM PACS 3.6.2 (Aug 27, 2020)

  • Bug fixes:
  • Fixed a bug that items in Recycle Bin cannot be restored when the database is Microsoft SQL Server Compact.
  • Fixed a bug that Logo and Key Image cannot be displayed in PDF of Report.

New in SonicDICOM PACS 3.6.0 (Jul 29, 2020)

  • New features:
  • Logos can be set for login page and header : Admin Settings > General > Option
  • Favicon can be set: Admin Settings > General > Option
  • Logo text in header can be switched show/hide: Admin Settings > General > Option
  • Recycle Bin feature has been implemented. Deleted Study/Series/Instance will be moved to Recycle Bin: Admin Settings > Server > Recycle Bin
  • On List page, Favorite feature has been implemented.
  • On List page, Note feature has been implemented.
  • On List page, a feature to select "Share With" from a shortcut when sharing Study/Patient has been implemented.
  • On List page, a feature to select "Expires At" from a shortcut when sharing Study/Patient has been implemented.
  • On List page, a feature to set the default value of "Expires At" when sharing Study/Patient has been implemented.
  • In dialog "Information of Share", a feature to select "Subject" from a shortcut has been implemented.
  • In dialog "Information of Share", a feature to select "Email" from a shortcut has been implemented.
  • In dialog "Information of Share", a feature to display the URL of shared Study/Patient as QR Code has been implemented.
  • Improvements:
  • The duration of Web Connection session has been changed from 30 minutes to 1 minute.
  • The loading time for the initial display of the web application has been accelerated.
  • Validation has been implemented in form of dialog.
  • On List page, file name can be specified when exporting DICOM files.
  • On Viewer page, file name can be specified when exporting JPEG/PNG/BMP files.
  • Other various improvements have been made.
  • Bug fixes:
  • Fixed a bug that in some version it fails to update to the latest version.
  • Fixed a bug that sometimes it accidentally displays a dialog that prompts to set Time Zone.
  • Fixed a bug that sometimes users are forced to log out when selecting Study/Series/Instance on List page.
  • Fixed a bug that the total number of studies is not renewed after auto-refreshing on List page.
  • Fixed a bug that sometimes resetting in User Settings does not work correctly.
  • Fixed a bug that sometimes editing Search Shortcut does not work correctly.
  • Fixed several other minor bugs.
  • Changes:
  • It has been changed that the deleted DICOM files will not be moved to the "Deleted" folder of the Main Data Path with the implementation of Recycle Bin feature. The DICOM files moved to Recycle Bin will be deleted automatically after a certain period of time.

New in SonicDICOM PACS 3.2.2 (Dec 26, 2018)

  • Fixed bug that login by using encryption method does not work correctly.
  • Fixed bug sometimes Web Connections cannot be counted correctly.
  • Fixed bug that Daily Backup of Database fails if it does not have permission to access to Path.
  • Fixed bug that Referring Physician's Name cannot be changed to blank when editing Account.

New in SonicDICOM PACS 3.2.1 (Dec 6, 2018)

  • Bug fixes:
  • Fixed bug that search of Study Date Range does not work correctly on Advanced Search.

New in SonicDICOM PACS 3.2.0 (Nov 13, 2018)

  • A feature to import JPEG file, PDF file, etc. by converting DICOM file is
  • implemented.
  • DICOM file information can be edited when importing.
  • Automatic backup of database is available.
  • In addtion, we have implemented other requested features.
  • And some improvements and bug fixes are done.
  • New features:
  • In List page, it can import JPEG/PNG/BMP/PDF file by converting to DICOM file.
  • In List page, it can add JPEG/PNG/BMP/PDF file to existing Study as Series by
  • converting to DICOM file. Feature name is "Add".
  • In List page, when importing DICOM files, it can edit information (Patient ID,
  • Patient Name, Accession Number, and AE Title).
  • In Report page, it can export PDF file.
  • On PACS Manager, it can set automatic backup of database file.
  • In Microsoft SQL Server, SQL Server Authentication is available.
  • Improvements:
  • In List page, AE Title and Performing Physician Name are available.
  • In List page, progress rate is availale for features of Edit, Delete, Import, Export,
  • and Forward.
  • In Viewer page, Toolbar can be switched show/hide (Alt + t).
  • In Viewer page, full-screen mode is available (Alt + f).
  • In Viewer page, various items can be switched show/hide by using Keyboard shortcuts.
  • In Viewer page, action of PgUp and PgDn in Keyboard shortcuts has been changed.
  • When opening Report page via URL, it can use Accession Number.
  • Bug fixes:
  • Fixed bug that login by using encryption method does not work correctly.
  • Fixed bug that sometimes edited information gets text garbling in List page.
  • Fixed bug that Modality information of Series cannot be edited in List page.
  • Fixed bug that sort by PatientAge does not work correctly in List page (it needs to
  • import all Studies again).
  • Fixed bug that Pie Charts in Dashboard page are not drawn correctly.
  • Fixed bug that edit of Window/Level Preset does not work correctly.
  • According to change of Google Chrome specification, some Keyboard Shortcuts have been
  • changed.
  • Fixed several other minor bugs.
  • Others:
  • Multi-monitor support and Key images of Report are postponed.

New in SonicDICOM PACS 3.1.1 (Aug 23, 2018)

  • Bug fixes:
  • Fixed bug it cannot display Monochromatic image of JPEG Lossy format.
  • Fixed bug sometimes position of Series scrollbar in Viewer page becomes incorrect.

New in SonicDICOM PACS 3.1.0 (Aug 22, 2018)

  • New features:
  • Image level Grid layout has been supported.
  • Keyboard shortcuts on Viewer page have been supported.
  • Language can be set for each Account.
  • Improvements:
  • It can select an action of double-cliking thumbnail in Viewer page: "Add a new Series" or "Replace a selected image".
  • It can place thumbnailbar on the right in Viewer page.
  • Image loading process has been optimized and its performance has been improved.
  • Progress rate of image loading has been supported.
  • Bug fixes:
  • Fixed bug sometimes it fails to import DICOM files on List page.
  • Fixed bug sometimes it cannot read Referring Physician Name correctly.
  • Fixed bug sometimes Web Connections cannot be counted correctly.
  • Fixed several other minor bugs.
  • Others:
  • Dutch has been added.
  • Persian has been added.
  • RTL (Right-to-Left) has been supported.
  • What's next:
  • Multi-monitor support
  • Key images of Report

New in SonicDICOM PACS 3.0.0 (Jun 11, 2018)

  • What's new in 3.0?:
  • The biggest change is that the fact you can customize it in various ways to meet your individual needs.
  • For example, you can change the user interface to your own language.
  • You can also hide the features you do not use, change the layout and order of the buttons, etc.
  • Administrator can control user permissions such as available features and Studies they can browse.
  • Also, distributors can change the product name and sell it as a product of their own brand.
  • Major new features & improvements:
  • Localization including multilingual support
  • Various customizations by User Settings
  • Setting account permissions
  • Control Study that can be browsed by setting "Referring Physician Name"
  • White Label option (change brand name)
  • Support for displaying on Tablet
  • Autosave of Annotation
  • Annotation: Text
  • Export JPEG/BMP file
  • Report: print/save as PDF
  • Other various features and improvements
  • Languages currently available:
  • Brazilian Portuguese
  • English
  • French
  • Italian
  • Japanese
  • Korean
  • Spanish
  • Vietnamese
  • # What's ne

New in SonicDICOM PACS 2.3.2 (Dec 14, 2016)

  • Bug fix:
  • Fixed bug of DICOM communication.
  • Changes:
  • The License Agreement has been renewed.

New in SonicDICOM PACS 2.3.1 (Dec 14, 2016)

  • Bug Fixes:
  • Fixed Bug that it cannot add and edit Accounts.
  • Fixed several other minor bugs.

New in SonicDICOM PACS 2.3.0 (Aug 24, 2016)

  • New Feature:
  • MPR has been implemented. It can reconstruct Coronal image and Sagittal image based on Axial image.
  • Bug Fixes:
  • Measurement: Fixed bug that it sometimes cannot run CTR properly.
  • Measurement: Fixed bug when it runs Polygon, sometimes StDev becomes NaN.

New in SonicDICOM PACS 2.2.5 (Aug 2, 2016)

  • Improvements:
  • Layers has been added to Mouse Dragging operation.
  • Thumbnail display speed has been improved.
  • A display method for overlays on a Viewer screen has been changed in case of there is not any specified DICOM tag.
  • Level of detail for log which will be output can be chosen by SonicDICOM Manager.
  • Bug fixes:
  • Fixed bug that it sometimes fails to get thumbnail.

New in SonicDICOM PACS 2.2.4 (Aug 2, 2016)

  • Improvements:
  • Improved performance of general image processing.
  • Improved performance of Window/Level adjusting.
  • Bug fixes:
  • Fixed bug that does not allow an Anonymous communication of Provider settings by default when you create new Provider.
  • Fixed bug that fails to load some images.
  • Fixed bug that the service sometime stops when fails to load some images.
  • Fixed bug that the SonicDICOM Media Viewer cannot open images if there is even one DICOM file which does not have PatientID.

New in SonicDICOM PACS 2.2.3 (May 25, 2016)

  • Bug fix:
  • Fixed bug preventing accurate rendering of images for OSs set to some locales including id-ID locale.

New in SonicDICOM PACS 2.2.2 (May 25, 2016)

  • Improvements:
  • Improved working speed when starting a measurement.
  • Delete selected or all annotations is now available.
  • Displaying area when you measure with also color image has been added.
  • Anonymizing of overlay for PatientBirthDate, StudyDate, StudyTime and AccessionNumber is now available.
  • Displaying the unit (mm) when you draw lengths on overlay has been added.
  • Displaying truncated number of digits after the decimal point when you display numerical values on overlay has been added.
  • Bug fixes:
  • Fixed bug forced logout when you overwrite report which created by other ID.
  • Changed specification of disabling for overwriting report which created by other ID
  • Fixed the transparent background of PNG Export Dialog with IE.
  • Fixed several other small bugs.

New in SonicDICOM PACS 2.2.1 (Apr 26, 2016)

  • Improvements:
  • The user interface of Grid in the Viewer screen has been improved.
  • Setting default Grid layout when opening Viewer screen is now available.
  • Other:
  • The description of Patient Root Query/Retrieve (SCP) has been added to DICOM Conformance Statement.
  • Many small improvements and small bug fixes.

New in SonicDICOM PACS 2.2.0 (Apr 26, 2016)

  • New Features:
  • Reporting function.
  • Exporting as PNG format.
  • Improvements:
  • The user interface of SonicDICOM Manager has been improved.
  • The DICOM server now supports Patient Root Query/Retrieve (SCP).
  • Report Status column has been added to the study list of the Worklist screen.

New in SonicDICOM PACS 2.1.0 (Mar 10, 2016)

  • New Feature:
  • An option for attaching SonicDICOM Media Viewer is now available when exporting DICOM files
  • Changes:
  • License Agreement has been updated
  • The ability to change the window size of SonicDICOM Manager is now available

New in SonicDICOM PACS 2.0.3 (Feb 29, 2016)

  • Important Changes:
  • We have changed the limitations in this version again. The limitations following the
  • change are as follows.
  • We have removed the limitation on the number of devices that can be connected
  • limitation has been removed.
  • We have added a limitation on the number of accounts that can be created.
  • Maximum number of accounts that can be created in the trial edition is 5.
  • Maximum number of studies that can be saved in the trial edition is 30.
  • Maximum number of accounts that can be created in the commercial edition is 10.
  • You can add more to the number of accounts that can be created in the commercial
  • edition.
  • There is no maximum in the number of studies that can be saved in the commercial
  • edition.
  • Bug fixes:
  • Fixed fatal bug preventing auto-startup of service upon OS boot-up.
  • Fixed bug preventing accurate rendering of images for OSs set to pt-BR locale.
  • Now possible to check more detailed service status in SonicDICOM Manager.
  • Fixed several other minor bugs.

New in SonicDICOM PACS 2.0.1 (Feb 15, 2016)

  • Many bugs are fixed and small improvements were done.

New in SonicDICOM PACS 2.0.0 (Feb 15, 2016)

  • Improvements:
  • Integration with external applications in the viewer screen is now available
  • New features:
  • Exporting function of DICOM file
  • Sending function of exam (DICOM Storage)
  • Bug fixes:
  • Fixed many bugs
  • Changes:
  • We have changed the limitation of the trial edition as below:
  • We have changed the maximum number of studies that can be saved to 30
  • We have newly added the limitation of maximum number of devices that can be connected to 5
  • The number of devices do not include the modality
  • You can reset the number of connected devices by restart the DICOMApp (Windows Service)
  • Other:
  • We have updated "Specifications of integration with external applications" (download)
  • White-labeling (OEM) option is now available

New in SonicDICOM PACS 1.6.0.0 (Feb 19, 2015)

  • Improvements:
  • JPEG 2000 image is now supported.
  • Processing speed of image display has been improved.
  • Web server is now faster.
  • Bug fixes: - Fixed a bug that some images cannot be displayed correctly.
  • Fixed a bug that some users cannot login.

New in SonicDICOM PACS 1.5.0.0 (Jan 7, 2015)

  • New features:
  • Polygon and CTR have been added to the measurement functions.
  • Improvements:
  • "SeriesDescription" and "BodypartExamined" have been added to the search criteria.

New in SonicDICOM PACS 1.4.0.0 (Dec 2, 2014)

  • New features:
  • Measurement functions are now available (Length, Angle, Cobb angle).
  • Integration with external applications is now available (specifications).
  • Improvements:
  • The display name of the item in the list screen can now be changed.
  • The default display state of the item in the viewer screen can now be changed.
  • Font size of the item in the viewer screen can now be changed.
  • The default fps of cine player can now be changed.

New in SonicDICOM PACS 1.3.2.0 (Nov 13, 2014)

  • Fixed bugs that some images cannot be displayed correctly.

New in SonicDICOM PACS 1.3.1.0 (Nov 10, 2014)

  • Upgrade of database has been simplified.
  • Fixed a bug that some images of JPEG Lossless format cannot be displayed correctly.
  • In addition, we've fixed some bugs.

New in SonicDICOM PACS 1.3.0.0 (Oct 7, 2014)

  • Changed the UI of the view screen;
  • Information about the study are now displayed in the sidebar.
  • Scroll bar is now available.
  • Improvements:
  • Multiframe image is now supported.
  • Processing speed of the server and the viewer has been improved.
  • New features:
  • You can select the number of series to be displayed. (maximum 6x6)
  • Scroll with keyboard.
  • Display of rulers.
  • Rotation function of the image.
  • Magnifying glass function.
  • Cine play function.

New in SonicDICOM PACS 1.2.0.0 (Sep 5, 2014)

  • Redesigned the user interface.
  • Display the status of the DICOM communication in real time.
  • Easier to understand the contents of the error that occurred in the DICOM communication.
  • Easier to save the error logs that occurred in the DICOM communication.
  • Easier to save files that failed to import.

New in SonicDICOM PACS 1.1.2.1 (Aug 22, 2014)

  • This is minor update with bug fixes and small improvements.

New in SonicDICOM PACS 1.1.2.0 (Aug 7, 2014)

  • DICOM Storage function is now available. You can select any Study, Series, Image and transmit it to a designated DICOM server.
  • All functions can now be used without being required to create an account

New in SonicDICOM PACS 1.1.1.0 (Jul 1, 2014)

  • Exporting function of DICOM files is now available:
  • You can choose the export format from "File only", "File into the folder" and "DICOMDIR".
  • The file format is ZIP or ISO.

New in SonicDICOM PACS 1.1.0.0 (Apr 24, 2014)

  • Improvements:
  • Renewed the UI of the list screen of the viewer.
  • You can now select the target item by pressing the ↑↓ keys when you have focus in the search box.
  • Bug fixes:
  • Some images can not be loaded.
  • DICOM viewer of some fails to DICOM Query.

New in SonicDICOM PACS 1.0.5.0 (Mar 14, 2014)

  • Study data editing function and deletion function released. We had planned to release these functions as paid version exclusive functions,
  • but we changed our plans to make them available to anyone with a free membership.
  • Conncetion with the modality is now easier. From this version, SonicDICOM will receive data even if the information of modality is not registered.
  • It should be noted that when connecting to the DICOM Viewer of other companies,
  • must make the user settings same as the conventional.
  • Please feel free to use them.

New in SonicDICOM PACS 1.0.4.0 (Feb 12, 2014)

  • Fixed a problem in which the DICOM files of non-English may be garbled.

New in SonicDICOM PACS 1.0.3.0 (Jan 21, 2014)

  • We added the configuration wizard function. By this, the initial setting is now more convenient. Simply run this wizard, you can be done to enable the import function from the configuration of the port number

New in SonicDICOM PACS 1.0.2.0 (Dec 13, 2013)

  • Fixed a bug that some of RGB Images can not be viewed correctly.

New in SonicDICOM PACS 1.0.1.0 (Dec 13, 2013)

  • Optimization in image processing.